Control Panel

Solution 2000 / 3000

 

 

en

Installation Guide

 

Содержание Solution 2000

Страница 1: ...Control Panel Solution 2000 3000 en Installation Guide ...

Страница 2: ......

Страница 3: ...er 24 4 16 DLA 24 5 Configuration 25 5 1 Installer Commands 25 5 1 1 Command 958 Exit from Installer s Programming Mode without saving changes 25 5 1 2 Command 959 Test IUI SOL ADAPTER 25 5 1 3 Command 960 Save and exit from Installer s Programming Mode 26 5 1 4 Command 961 Reset the Control Panel to Factory Default Settings 26 5 1 5 Command 962 Copy the Control Panel Memory to IUI SOL ADAPTER 26 ...

Страница 4: ...rm Disarm 50 7 2 Master Code Functions 51 7 2 1 Arm or Disarm both Areas at the Same Time 51 7 2 2 Arm or Disarm Single Area 51 7 2 3 Changing and Deleting User Codes 52 7 2 4 Adding Remote Radio User Codes 53 7 2 5 Deleting User Radio Codes 53 7 2 6 Change Domestic Phone Numbers 54 7 2 7 Change Telco Arm Disarm Sequence 54 7 2 8 Setting STAY Mode 2 Bypass Zone 54 7 2 9 Turning Outputs On and Off ...

Страница 5: ...er for Receivers 69 11 2 Secondary Telephone Number for Receivers 69 11 3 Transmission Format for Receivers 69 11 4 Subscriber ID Number for Receivers 70 11 5 IP Items for Receivers 70 11 6 Conettix Items for Receivers 71 11 7 External Network Modules 72 11 8 Network Module Cloud Connection 73 11 9 Password for A Link Connection 73 11 10 DTMF Timing Compensation 73 11 11 Country Codes 73 11 12 Tel...

Страница 6: ...ne Status Reporting Options 106 14 RF Information 107 14 1 RF Supervision Time 107 14 2 Anti Jamming Sensitivity 107 14 3 RF Receiver 108 14 4 RF Options 108 14 5 RFID 108 14 5 1 RF Keyfob RFID 109 14 5 2 RF Device RFID 109 14 5 3 RF Reapter RFID 110 15 System Reporting Information 111 15 1 Arm Disarm Reporting Options 111 15 2 Codepad Reporting Options 111 15 3 Access Denied 111 15 4 System Statu...

Страница 7: ...try Exit Times 134 17 2 Entry Time 1 134 17 3 Entry Time 2 134 17 4 Exit Time 134 17 5 Entry Guard Time for STAY Mode 135 17 6 Delay Alarm Reporting Time 135 17 7 Sensor Watch Time 135 17 8 Codepad Lockout Time 136 17 9 Siren Run Time 136 17 10 Siren Sound Rate 136 17 11 Auto Arming Pre Alert Time 136 17 12 Auto Arming Time 137 17 13 Auto Disarming Time 137 17 14 Kiss Off Wait Time 137 17 15 Speak...

Страница 8: ...19 2 1 Zone Area Assignments 145 19 2 2 Codepad assignment 146 19 2 3 User code area assignments 146 20 Text Information 148 8 en Table of Contents Control Panel 2017 10 03 F 01U 298 026 Installation Guide Bosch Security Systems Inc ...

Страница 9: ...damage to the equipment or environment Caution These indicate a hazardous situation which if not avoided could result in minor or moderate injury Warning These indicate a hazardous situation which if not avoided could result in death or serious injury Copyright This document is the intellectual property of Bosch Security Systems Inc and is protected by copyright All rights reserved Trademarks All ...

Страница 10: ...10 en Introduction Control Panel 2017 10 03 F 01U 298 026 Installation Guide Bosch Security Systems Inc ...

Страница 11: ...0 Number of users 32 32 Number of zones 4 4 ZD 8 8 ZD Number of areas partitions 2 2 Number of on board outputs 4 4 Number of codepads 4 4 Number of B308 Octo output modules 2 2 Number of B426 IP communicators 2 2 Number of B442 or B450 GPRS communicators 2 2 Number of WE800EV2 receivers 1 1 2 2 1 2 2 2 2 1 Control Panel System Overview en 11 Bosch Security Systems Inc Installation Guide 2017 10 0...

Страница 12: ...u might already have these parts Accessory Type Solution 2000 Solution 3000 Codepads Touchscreen IUI SOL ICON IUI SOL TEXT Touchscreen IUI SOL ICON IUI SOL TEXT Keyfobs HCT 4 HCT 4 RFKF TB RFKF FB Octo output modules B308 B308 Receivers WE800EV2 WE800EV2 B810 Repeaters RFRP Detectors Wired detectors Wired detectors RADION wireless detectors Software A Link Plus A Link Plus Ethernet communication m...

Страница 13: ...structions should always be available on site It is a required part of the system and must be given to the new owner if the system is ever sold Use the workflow and checkboxes below as you complete steps Install the enclosure Install the control panel Install and wire for telephone communication Install and wire for IP communications Install and wire the transformer Install and wire arming devices...

Страница 14: ...8 0 9 5 6 1 4 7 2 5 8 3 6 9 STAY AWAY 0 1 2 3 4 5 6 7 8 ON OFF Installation Set the address switches for the proper address mount the mounting plate wire to the control panel and attach the codepad to the mounting plate Notice Do not remove the spring from the tamper switch on the IUI SOL ICON Removing the spring will cause a Codepad Tamper Trouble and a report will be sent if configured to do so ...

Страница 15: ...ad DIP switch address settings Install the module 1 Use the provided anchors and screws to mount the codepad base on the wall 2 Pull the necessary wiring through the mounting plate Wire to the control panel Wire the codepad to the control panel using the control panel terminals labeled R Y G B PWR A B COM Connect them to the codepad terminals labeled R Y G B Connect codepads to the SDI2 data bus b...

Страница 16: ... Method 1 By Text Menu 1 Enter the Installer Code followed by or key for example 1234 2 Then press keys 3 1 3 to enter Exit time and program the exit time Method 2 By address programming 1 Enter the Installer Code followed by or key for example 1234 2 Press 8 1 to enter address programming 3 Press 470 to enter Exit Time address to program To program Exit Time using the IUI SOL ICON Enter the Insta...

Страница 17: ...power up 5 Phone remote arm 6 Answer machine bypass on arm 7 Ignore AC fail 1 AC fail report wait time 2 Warning device fault monitor 3 Phone line fault indicator 4 Phone line fault alarm on armed 5 Phone line fault alarm on disarm 6 Lockout phone line fail alarm 7 RF receiver 1 Zone RFID and input option 2 Keyfob RFID 3 Repeater RFID 4 RF supervision time 5 RF jam sensitivity 6 RF RECE jam tamper...

Страница 18: ...nd output Siren config 1 2 3 4 Comm 7 Receiver config Network config Report config Comm option 1 Comm option 2 1 2 3 4 5 Network module 1 A Link RSC password 2 Parameter 8 Address program Address auto step Adapter 1 2 3 Test adapter 1 Read adapter 2 Write adapter 3 267 502 2536 265 381 266 392 379 380 498 4 396 3 492 1 494 3 494 4 501 2 500 3 518 436 460 646 177 4 0 40 1417 1457 16 56 1433 1473 33...

Страница 19: ...e remote Panic Alarms It can also operate outputs such as garage doors swimming pool pumps or outside lights RADION receiver B810 The B810 is a wireless receiver that connects RADION wireless peripherals such as the motion detectors keyfobs panic buttons repeaters and more to supported Bosch control panels using the SDI2 Bus connection For more information refer to the installation and operation m...

Страница 20: ... settings Outputs can be programmed for remote control from a control panel codepad or computer A Link or smartphone application RSC Set the address Two address switches determine the address for the B308 Octo output Module The control panel uses the address for communications Use a slotted screwdriver to set the two address switches Set the address switches per the control panel configuration The...

Страница 21: ...ath supervision AES encryption and anti substitution features make B426 desirable for high security and fire monitoring applications It is capable as a stand alone path or it can be used in conjunction with another communication technology For Fire Monitoring applications the B426 meets UL864 and NFPA72 standards for Single Communication Technology with approved Bosch control panels B450 B450 M Co...

Страница 22: ...ng a data bus connection via the module s terminal strip or the module s interconnect wiring connectors For data bus powered installations outside the compatible control panel enclosure follow the maximum wiring distances in the technical specifications For further installations power from a compatible auxiliary power supply A Link Plus Software You can program or control the Solution 2000 3000 co...

Страница 23: ...he installation files 1 Go to the Bosch website au boschsecurity com 2 Click on the Products tab and select Intrusion Alarm Systems 3 On the right side of the page under Online Tools click the Remote Access Profile Builder link 4 After reviewing the required prerequisites click Install 5 Save the install file to your computer hard drive The Remote Security Certificate Builder link also includes th...

Страница 24: ... the terminals opens the internal fuse causing permanent failure Connect the transformer to the 18 22 VAC terminals of the control panel before plugging it into the power source Notice Plan Ahead Route telephone SDI2 bus wiring and sensor loop wiring away from any AC conductors including the transformer wire AC wiring can induce noise and low level voltage into adjacent wiring 1 Use 18 AWG 1 02 mm...

Страница 25: ...ing Mode from any location To exit from Installer s Programming Mode Enter 9 6 0 The system returns to the disarmed state When using the codepad the STAY and AWAY indicators are extinguished Command 959 Test IUI SOL ADAPTER This command initiates a test of the direct link adapter You can only use the IUI SOL ADAPTER Direct Link Adapter with the control panel The direct link adapter test is non des...

Страница 26: ... flash on the codepad to indicate that you entered Installer s Programming Mode The codepad displays the data stored in Location 000 2 Enter 9 6 1 Two beeps sound and the system is reset to the factory default values When working with a text codepad go to Menu 138 Factory default to reset the system to factory default settings Command 962 Copy the Control Panel Memory to IUI SOL ADAPTER This comma...

Страница 27: ...Command 965 Set up Domestic Dialing Format Command 965 simplifies the setup of the domestic dialing format to a one step operation Refer to Domestic Dialing page 79 for more information To set up domestic dialing format 1 Enter the Installer Code the default is 1234 and press to enter Installer s Programming Mode Two beeps sound and the STAY and AWAY indicators flash on the codepad to indicate you...

Страница 28: ... 6 6 Two beeps sound To disable the automatic stepping of locations Enter 9 6 6 Two beeps sound Example Auto Step Enabled To enter the Primary Telephone Number 02 pause 9672 1055 when auto step is enabled 1 Press 0 You are positioned at Location 000 the Primary Telephone Number for Receiver 1 2 Program the number by pressing 10 2 13 9 6 7 2 1 0 5 5 0 Example Auto Step Disabled To enter the Primary...

Страница 29: ...d to require the Installer Code for future control panel programming If the Installer Code is unknown you must restore the control panel to your Bosch distributor for exchange A nominal fee applies for this service Notice The use of this feature is not recommended If you are required to disable the ability restore the control panel to its default settings a special procedure eliminates the possibi...

Страница 30: ...estored To restore the default control panel settings using the default button 1 Disconnect the AC MAINS supply and the backup battery from the control panel 2 Press and hold the DEFAULT button 3 Reconnect the AC MAINS supply to the control panel 4 Wait 3 to 5 sec and release the DEFAULT button 5 Enter 2580 to disarm the system using the default Master Code The control panel default factory settin...

Страница 31: ...fer to Consumer Options 2 page 142 1 Press and hold AWAY 2 When two beeps sound release the button The AWAY indicator lights and Exit Time starts If a zone is not sealed at the end of Exit Time the zone is automatically isolated and its indicator is lit on the codepad The zone becomes an active part of the system again as soon as it is resealed For example if a window is open when Exit Time expire...

Страница 32: ...t automatically isolated is activated the codepad beeps twice per sec until the Entry Guard Time for STAY Mode expires or the system is disarmed If the alarm is not reset before Entry Guard Time for STAY Mode expires the strobe bell and siren outputs are activated into alarm Notice Single button arming in STAY Mode 1 reports as User Code number 00 To arm the system in STAY Mode 1 method one 1 Ente...

Страница 33: ...you need to arm the perimeter and unused areas of the premises to detect a would be intruder from entering the premises while at the same time being able to move freely within an area that is automatically isolated You can program zones to be automatically isolated in STAY Mode 2 using an Installer Code function refer to Installer Code Functions page 41 or a Master Code function Master Code Functi...

Страница 34: ...he first method You can use method two only if Option 4 is enabled in Location 497 refer to Consumer Options 2 page 142 To disarm the system from STAY Mode 2 method one 1 Enter your code and press STAY 2 Two beeps sound and the STAY indicator is extinguished The system is now disarmed To disarm the system from STAY Mode 2 method two A flashing zone indicator represents a previous alarm in that zon...

Страница 35: ...hod is used Standard isolation does not require a User Code The other method requires a valid User Code The ability to isolate zones is determined by the priority level assigned to each User Code holder Some User Code holders cannot isolate zones Refer to User Code Priority page 89 for more information Zones that are manually isolated using this method transmit a Zone Bypass Report Contact ID Even...

Страница 36: ... the zone to be isolated and press STAY The indicator for the zone flashes 24 Hour zones are automatically isolated as soon you press STAY All other Burglary zones are automatically isolated only after the system is armed 4 Repeat Step3 for each zone you want to isolate Notice As each zone is selected to be isolated the corresponding zone indicator flashes If you make a mistake enter the incorrect...

Страница 37: ...2000 N A 2 1 to 16 Zones 1 to 16 RF Low Battery 3 Zone Tamper Alarm 3 1 to 16 Zones 1 to 16 Tamper Alarm 4 Sensor Watch Fault 4 1 to 16 Zones 1 to 16 Sensor Watch Fail 5 RF Sensor Missing Solution 2000 N A 5 1 to 16 Zones 1 to 16 RF Sensor Watch Fail 6 Communication Fail 6 1 2 3 4 5 6 Receiver 1 Fail Receiver 2 Fail Receiver 3 Fail Receiver 4 Fail IP Module 1 Fail IP Module 2 Fail 7 Output and Cod...

Страница 38: ...h fault 6 Communication Fail A communication fail registers when the control panel fails to communicate with the receiving party such as a monitoring company mobile phone The communication fault clears once the control panel successfully reports to the receiving party A communication fail also registers when network module is disconnected or tampered To determine which receiver or module failed to...

Страница 39: ...sconnected continuously for longer than 2 min the remote codepad beeps the codepad buzzer once per min If the control panel is programmed to report an AC MAINS failure to a base station receiver an AC Fail Report Contact ID Event Code 301 is transmitted The MAINS indicator stops flashing when the AC MAINS supply is reconnected When the AC MAINS supply is connected continuously for 2 min the codepa...

Страница 40: ...Enter your Installer Code or User Code followed by 2 Press 1 2 3 the cloud status is shown 3 Press the UID is shown 4 Press to exit 40 en System Operations Control Panel 2017 10 03 F 01U 298 026 Installation Guide Bosch Security Systems Inc ...

Страница 41: ...tions only when the system is disarmed Installer Code Functions Function Description 0 Add delete RF wireless devices keyfobs repeaters 1 Set the number of days until the first Test Report 2 Change domestic telephone numbers 3 Change the Telco arm disarm sequence 4 Set bypass zones for STAY Mode 2 6 Turn report monitor mode on and off 7 Walk test mode 8 Event memory recall mode 9 AWAY arm disarm A...

Страница 42: ... to finish this function and reset the control panel 6 The user can press STAY to cancel the wireless zone enrollment at any step except during the delete process The codepad sounds one error beep cancels the enrollment and exits Example To add RF wireless device number 3 whose 9 digit ID number is 000094946 enter 1 2 3 4 0 AWAY 3 AWAY 0 0 0 0 9 4 9 4 6 AWAY AWAY To delete an RF wireless device 1 ...

Страница 43: ... Refer WE800EV2 manual for learn delete fobs Notice Set RF receiver as WE800EV2 Receiver Value 2 in Location 395 1 Enter the Master Code followed by 1 and the key for example 25801 2 Enter the WE800EV2 keyfob number 301 to 332 you want to add 301 keyfob 1 302 keyfob2 etc followed by the key Up to 21 WE800EV2 keyfobs can be added but only current keyfob number 1 to 16 displays through zone indicato...

Страница 44: ...eyfob Example To delete existing RADION keyfob 1 Enter your Master Code and press 1 3 0 1 7 1 3 2 More than 3 heading levels are not supported Using an Alphanumeric codepad Notice Set RF receiver as WE800EV2 or RADION receiver through the menu 3 5 1 Add the Keyfob 1 Enter the Master Code followed by 1 and the key for example 25801 2 Choose a user number then press the key 3 Choose keyfob then pres...

Страница 45: ...tic phone numbers 1 Enter your passcode and press 2 AWAY Three beeps sound and the STAY and AWAY indicators flash There are 8 telephone number locations Numbers 1 and 2 are for receiver 1 Numbers 3 and 4 are for receiver 2 Numbers 5 and 6 are for receiver 3 Numbers 7 and 8 are for receiver 4 2 Press the sequence number to view and set modify the corresponding telephone number If telephone numbers ...

Страница 46: ... This allows you to program the Call Forward Immediate On sequence or Call Forward No Answer sequence that automatically operates when you arm the system in the AWAY Mode Notice The examples provided for this feature apply only to Australia Call Forward Immediate On You can redirect calls to anywhere in Australia including mobiles and answering services When this Call Forward option is turned on t...

Страница 47: ...quence Enter your passcode and press 3 AWAY 1 AWAY STAY 5 AWAY To program the telco disarming sequence 1 Enter your passcode and press 3 AWAY Three beeps sound and the STAY and AWAY indicators flash 2 Press 2 AWAY to change the telco disarming sequence Three beeps sound If a telco disarming sequence is already programmed the sequence is displayed one digit at a time using the codepad indicators Re...

Страница 48: ...rt Monitor Mode allows you to use the codepad for visual representation of data transmissions between the control panel and the base station receiver The transmission sequence is also shown in this mode The codepad beeps once every two sec when Report Monitor Mode is active whether the system is in Installer s Programming Mode or normal operating mode The first five indicators on the ICON codepad ...

Страница 49: ...and the horn speaker sounds one short beep each time a zone is sealed or unsealed 3 Press AWAY to exit from this function Two beeps sound and the STAY and AWAY indicators are extinguished The system returns to the disarmed state Event Memory Recall Mode This function allows you to play back the last 256 system events that occurred Event Memory Recall Mode reports all alarms and each arming or disa...

Страница 50: ...differentiation between STAY Mode 1 and STAY Mode 2 If the control panel is powered down the memory of all events is saved AWAY STAY 1 Arm Disarm This function allows you to arm disarm the system in AWAY mode or in STAY 1 mode with the installer code To arm the system in AWAY mode 1 Enter the Installer Code and press 9 AWAY 2 Two beeps sound the AWAY indicator lights and Exit Time starts To disarm...

Страница 51: ...n outputs on and off 6 Set the date and time 7 Walk test mode 8 Event memory recall mode 9989 System reset Table 7 3 Master Code Functions Arm or Disarm both Areas at the Same Time This Master Code function only operates with partitioned control panel systems and allows Master Codes allocated to both Area 1 and Area 2 to arm or disarm both areas at the same time This feature allows a Master Code h...

Страница 52: ... a User Code When using a partitioned Control Panel the Master Code holder cannot add change or delete User Codes unless the User Code is allocated to the same area as the Master Code Refer to User Code Priority page 89 for more information To change a User Code 1 Enter your Master Code and press 1 AWAY Three beeps sound and the STAY and AWAY indicators flash 2 Enter the number of the code 1 to 32...

Страница 53: ... the ICON codepad 3 Use manual mode or auto learn mode to configure the RADION keyfob RFID In manual mode enter the 9 digit RF device ID number followed by or press to switch into auto learn mode When icon numbers 1 to 16 flash press the 1 or 2 button on the keyfob The control panel learns the RADION keyfob ID number and the last digit of RFID number displays on the codepad Press to confirm 4 Pres...

Страница 54: ...trol output 4 Output Event Type 6 2 Remote control output 5 Output Event Type 6 3 Remote control output 22 Output Event Type 7 4 To turn an output on from the codepad 1 Enter your Master Code and press 5 AWAY Three beeps sound and the STAY and AWAY indicators flash 2 Enter the number of the output 1 to 22 and press AWAY Three beeps sound and the output turns on 3 Repeat Step2 to turn on another ou...

Страница 55: ...inute of the day and press AWAY Use 24 00 hour format when programming the hour of the day Two beeps sound and the STAY and AWAY indicators are extinguished If a long beep sounds an error occurred when you entered the date and time Example To set the date and time for 1st January 2014 at 10 30 PM enter 2 5 8 0 6 AWAY 0 1 0 1 1 4 2 2 3 0 AWAY Walk Test Mode See also Walk Test Mode page 49 Event Mem...

Страница 56: ...ates only if you select Option 2 in Location 497 refer to Consumer Options 2 page 142 If there was no alarm during the armed cycle holding down a sec time disarms the system from STAY Mode 1 To enable single button disarming from STAY Mode 1 using this hold down function select Option 4 in Location 497 If an alarm occurred or entry warning was activated a valid User Code is required to disarm the ...

Страница 57: ... Press and hold 4 until two beeps sound Fault Analysis Mode Several system faults can be detected by the control panel When any of these faults are present the FAULT indicator flashes and the codepad beeps once per minute Refer to Fault descriptions page 37 for more information To determine the type of fault Press and hold 5 until two beeps sound The STAY and AWAYindicators flash One or more zone ...

Страница 58: ...ou must reset each codepad to its individual tone using this function On partitioned control panels this hold down function also indicates the area to which the codepad belongs To determine the area to which the codepad belongs 1 Press and hold 8 until two beeps sound A zone indicator lights to show the area to which the codepad belongs Zone 1 Area 1 codepad Zone 2 Area 2 codepad Zone1 2 Common Co...

Страница 59: ...provided by the horn speakers or the strobe These indications allow you to operate the system from outside the premises with confidence The installer can program audible and visual indication beeps by selecting Options 4 and 8 in Location 492 refer to System Options 1 page 138 You can adjust the speaker beep volume in Location 491 refer to Speaker Beep Volume page 137 No of Beeps System Status One...

Страница 60: ...e system remotely 2 Press on the touch tone telephone to arm the system Two beeps sound to indicate that the system is armed in AWAY Mode 3 Hang up the telephone The system remains armed If the control panel does not answer the call the ring count might be set to 0 If the control panel answers the call without modem tones remote arming by telephone might not be enabled To enable remote arming by t...

Страница 61: ...ad Download functions from multiple locations Notice Reduced security Using the modem connection without callback verification feature reduces the security of the control panel There are two methods to disable callback verification Method One Method one allows you to call the control panel from any remote location without the control panel calling back to the computer to establish a link When usin...

Страница 62: ...e Modem to the computer 2 Program A Link plus Option in location 180 as 1 3 Program Ring Count in location 175 as 14 or 15 4 On the A Link Plus Customer Information screen select Answer Machine Bypass and set Modem Dial Time and Dial Interval Modem Dial Time is from the start of the first call to the end of the first call This value sets the number of rings noting that one ring is Ring Ring Ring R...

Страница 63: ...26 M network module to the control panel using the SDI2 bus 2 Program Location 81 or 82 as Option 1 or 2 or 3 enable Cloud Connection with the alphanumeric codepad when Option 3 is selected 3 From the A Link Plus Customer Information tab instead of full control panel IP address for the B426 enter the domain name for example Test123 BOSCH com and enter the full control panel port number for the mod...

Страница 64: ...n Web Access Enable are set to Yes B426 B426 M module parameters except Email parameters can be configured through web interface Email parameters are configured through A Link Plus and downloaded to the control panel Follow the steps below to configure necessary parameters to network module and send emails through the module Step 1 Enable network module with an Alphanumeric codepad 1 Enter the Ins...

Страница 65: ...ct the Control Panel Configuration tab Select Solution 2000_V2 00 or Solution 3000_V2 00 according to your control panel type 5 Select the Link tab Select Network Connect Cloud and click Connect A Link Plus tries to connect to the control panel using the B426 M 6 Click Upload from Control Panel Step 4 Configure the Email through A Link Plus 1 Select the Control Panel Configuration tab and configur...

Страница 66: ...work Module 1 or 2 and press 3 Select 3 Used B4xx M and press 4 Select 1 Enable and press 5 Continue to press until you return to Confirm to Save Parameter Changes 6 Press to save changes Step 2 Reset module to factory default If the parameters of the B450 B450 M with B442 B443 inserted are already set to their factory default values skip the steps below and go to the next set of steps 1 Power off...

Страница 67: ...ntrol Panel Step 5 Configure the Email through A Link Plus 1 Open A Link Plus go to Control Panel Configuration tab Select Solution 2000_V2 00 or Solution 3000_V2 00 according to your control panel type 2 Configure email related parameters 3 Select the Link tab select a connect method and click Connect Click Download to Control Panel when the connection is successes to complete the process Configu...

Страница 68: ...a 0 Each location in the primary secondary and callback telephone numbers stores one digit of the telephone number You must insert a terminator 15 at the end of a telephone number to indicate to the communicator the end of the telephone number is reached The dialing sequence terminates when a 15 appears Example To program the telephone number 9672 1055 as the Primary Telephone Number for Receiver ...

Страница 69: ...r 2 are programmed this procedure is repeated every 10 min continuously till the report is transmitted successfully Contact your monitoring station for the correct telephone numbers before you program these locations With a text codepad go to menu 711 First Phone Number to program the primary telephone numbers Secondary Telephone Number for Receivers Item Location Option Default New Phone Number 2...

Страница 70: ...f up to 10 different control panels that call the same telephone number With a text codepad go to menu 714 Subscriber ID Number to set Subscriber ID Number for Receiver 1 and Receiver 2 Example To program the Subscriber ID Number as 4729 program the six locations as 0 0 4 7 2 9 IP Items for Receivers Item Location Option Default New IP Port Email Receiver 1 1000 1099 CSVIP User Name and Password R...

Страница 71: ...ters as below table Codepad Key Characters Function Codepad key Characters Function Step back former character 6 m n o 6 _ Exit item setting 7 p q r s 7 Move to next character 8 t u v 8 1 _ 1 9 w x y z 9 2 a b c 2 Case shift 3 d e f 3 0 Space 0 4 g h i 4 Confirm item setting 5 j k l 5 Table 11 2 Alphanumeric on Alphanumeric codepad Program Email with A Link Plus Refer to Configure through B426 B42...

Страница 72: ...s supervising signals to the receiver to ensure the network connect is normal With a text codepad go to menu 717 Conettix ACK wait time 718 Conettix heart beat time and 719 Conettix anti replay enable to set Conettix parameters for receivers External Network Modules Item Location Option Default New External Network Module 1 0081 0 Not used 1 Use do not configure 2 Use and configure 3 Used B4xx M 0...

Страница 73: ... 0 DTMF Timing Compensation is used to pre compensate signal distortion generated by digital telephone applications Fiber telephone VoIP or GSM module It can help to reduce failures in alarm communication DTMF Timing Compensation works only with Contact ID format Defaulted 0 is to disable this function and the communication capabilities remains the same Enable this function by selecting value from...

Страница 74: ...answer on enter 6 1 forwarding telephone number Example To forward all incoming calls when there is no answer to the telephone number 96721055 after arming the system in AWAY Mode program 11 6 1 9 6 7 2 1 0 5 5 12 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 Telco Disarming Sequence Item Location Option Default New Telco Disarm Sequence Call Forward Off 0143 0158 15 Telephone termination ...

Страница 75: ...ote Arming or Upload Download when an answering machine or facsimile machine is on the same telephone line Answering Machine Bypass has two different methods Program a 14 to use the secondary method only when there is a large amount of traffic on the line at a home office for example This method reduces the chance of the control panel incorrectly answering an incoming call Programming the Ring Cou...

Страница 76: ...Telephone Line Fails When this options is selected the FAULT indicator flashes and the codepad buzzer beeps once per min if the control panel detects that the telephone line is disconnected 2 Sound Alarm when System Is Armed You must also select Option 1 to use this option If the control panel detects that the telephone line is disconnected when the system is armed the horn speaker bell and strobe...

Страница 77: ... This option is beneficial in high telephone traffic installations where the control panel could answer an incoming call 8 Use Bell 103 for FSK Format Disabled CCITT V21 If this option is selected the control panel uses the BELL 103 transmission frequency at 300 baud If this option is not selected the control panel uses the CCITT V21 transmission frequency at 300 baud Communication Options 2 Item ...

Страница 78: ...a valid handshake tone after it dials the monitoring station The handshake tone indicates to the control panel that it reached the monitoring station and can now transmit its messages Selecting this option extends this wait time from 30 sec to 60 sec Communication Options 3 Item Location Option Default New Communication Options 3 0179 1 Set DTMF dialing pluses to 1 digit sec 2 Lockout telephone li...

Страница 79: ...ing with a remote computer using the A Link Plus software over the telephone line the A Link session is terminated and the relevant alarm message is transmitted to the base station receiver If an alarm occurs that does not have to be reported to the base station receiver the session is not terminated Domestic Dialing The locations of the primary and secondary telephone numbers for Receiver 1 2 3 4...

Страница 80: ...e Two beeps sound and the STAY and AWAY indicators flash 2 Enter 9 6 5 and press AWAY Two beeps sound The control panel is now set up for Domestic Dialing Format for Receiver 1 3 Enter 9 6 0 and press AWAY to exit from Installer s Programming Mode Two beeps sound and the STAY and AWAY indicators are extinguished The system returns to the disarmed state 4 Or skipping steps 1 3 with a text codepad e...

Страница 81: ... Email format is selected the information is transmitted to network by external network modules The control panel is set at the factory to report in the Contact ID Format Contact ID Format Contact ID Format can identify hundreds of protection zones by their unique codes This format provides a single digit Event Qualifier and a three digit Event Code that quickly identifies the reported condition I...

Страница 82: ...1 ZoneAlarm 1130 Zone 1 8 16 BA Z Alarm 2 ZoneAlarmRestore 3130 Zone 1 8 16 BH Z Alarm Restore 3 ZoneTrouble 1380 Zone 1 8 16 BT Z Trouble 4 ZoneTroubleRestore 3380 Zone 1 8 16 BJ Z Trouble Restore 5 ZoneBypass 1573 Zone 1 8 16 BB Z Bypass 6 ZoneUnBypass 3573 Zone 1 8 16 BU Z UnBypass 7 24HrZoneAlarm 1133 Zone 1 8 16 BA 24Hr Z Alarm 8 24HrZoneAlarmRestore 3133 Zone 1 8 16 BH 24Hr Z Alarm Restore 9...

Страница 83: ...c Z Trouble 26 24HrPanicZoneTroubleRestor e 3375 Zone 1 8 16 PJ 24Hr Panic Z Trouble Restore 27 24HrHoldUpZoneTrouble 1376 Zone 1 8 16 HT 24Hr Hold Up Z Trouble 28 24HrHoldUpZoneTroubleRest ore 3376 Zone 1 8 16 HJ 24Hr Hold Up Z Trouble Restore 29 24HrFireZoneTrouble 1373 Zone 1 8 16 FT 24Hr Fire Z Trouble 30 24HrFireZoneTroubleRestore 3373 Zone 1 8 16 FJ 24Hr Fire Z Trouble Restore 31 24HrBypass ...

Страница 84: ...RF Sensor Battery Restore 53 KeyfobLowBattery 1384 301 332 XT Keyfob Low Battery 54 KeyfobLowBatteryRestore 3384 301 332 XR Keyfob Battery Restore 55 Disarm 1401 User 1 32 OP User Installer QuickArea Disarm 56 AwayArm 3401 User 1 32 CL User Quick PowerUp Area AWAY Arm 57 Stay1Arm 3441 User 1 32 NL User A Link Quick PowerUp Area STAY1 Arm 58 Stay2Arm 3456 User 1 32 NM A Link Quick PowerUp Area STAY...

Страница 85: ...ingRestore 3333 821 EN RF Repeater Missing Restore 83 RFRepeaterTamper 1341 821 XS RF Repeater Tamper 84 RFRepeaterTamperRestore 3341 821 XJ RF Repeater Tamper Restore 85 CodepadMissing 1333 881 884 EM Codepad Missing 86 CodepadMissingRestore 3333 881 884 EN Codepad Missing Restore 87 CodepadTamper 1341 881 884 ES Codepad Tamper 88 CodepadTamperRestore 3341 881 884 EJ Codepad Tamper Restore 89 IPM...

Страница 86: ... OutputFailRestore 3320 891 YH Warning Device Restore 110 CommFail 1354 891 YC Comm Fail 111 CommRestore 3354 891 YK Comm Restore 112 CommManualTest 1601 000 RX Comm Manual Test 113 CommAutoTest 1602 000 RP Comm Auto Test 114 DateTimeSet 1625 User 1 32 998 A Link JT User A Link Set Clock 115 WalkTestBegin 1607 000 Installer User 1 32 Walk Test Begin 116 WalkTestEnd 3607 000 Installer User 1 32 Wal...

Страница 87: ...on The next time the Installer Code is used enables access to Installer s Programming Mode Installer Code functions allow the installer to execute functions when the system is disarmed without the customer s Master Code See also Installer Code Functions page 41 Installer Commands page 25 User Codes Item Location Default New Authority Level Location Default New User 01 0185 0186 0187 0188 2 5 8 0 0...

Страница 88: ... User 25 0606 0609 15 0610 2 User 26 0611 0614 15 0615 2 User 27 0616 0619 15 0620 2 User 28 0621 0624 15 0625 2 User 29 0626 0629 15 0630 2 User 30 0631 0634 15 0635 2 User 31 0636 0639 15 0640 2 User 32 0641 0644 15 0645 2 Authority Levels Description 0 Arm Disarm 1 Arm Only 2 Arm Disarm and Arm Disarm Reports 3 Arm Only and Arm Reports 4 Arm Disarm and Code Required to Isolate 6 Arm Disarm and ...

Страница 89: ...al User Code is reported when any of these methods are used to arm or disarm the system User Code 998 Arming and disarming using the A Link Plus software User Code 995 Arming remotely by telephone User Code 000 Single button arming disarming in AWAY Mode STAY Mode 1 or STAY Mode 2 User Code 997 Automatic arming disarming in AWAY Mode or STAY Mode 1 User Code 994 When Arm Disarm Tracking on Power U...

Страница 90: ...method Master Code Functions Master Code functions allow those users that have the appropriate priority level to perform certain supervisory level functions You can use these functions only when the system is disarmed Notice The default Master Code User Code 1 is 2580 It is possible to program multiple Master Codes To access a Master Code function enter the Master Code and press the corresponding ...

Страница 91: ...esetting operates when a zone programmed for Day Alarm is activated The output is reset after the zone is resealed This occurs only when the system is disarmed Refer to 0 14 Day Alarm Resetting in Output Event Types page 123 for more information Day Alarm Latching An output that is programmed for Day Alarm Latching operates when a zone programmed for Day Alarm is activated The zone indicator and t...

Страница 92: ... for different end of line EOL resistor values This is a global parameter that affects all zones simultaneously This feature allows you to install the control panel at an existing site without changing the EOL resistors This feature also increases the security of the system because eleven possible EOL resistor values can be used which makes it extremely difficult to tamper with the system For No E...

Страница 93: ...r reporting information for the zone Zone Operating Information These locations store the Zone Type for example Delay 1 Instant or 24 Hour the Zone Pulse Count and the Zone Pulse Count Time The Zone Pulse Count specifies the number of times the zone must activate within the time specified in the Zone Pulse Count Time Refer to Zone Types page 97 Zone Pulse Count page 99 and Zone Pulse Count Time pa...

Страница 94: ...eport Options 280 1 Zone 03 Default Handover Zone Type 281 1 Zone Pulse Count 282 0 Zone Pulse Count Time 283 0 Zone Options 1 284 1 Zone Options 2 285 14 Zone Report Options 287 1 Zone 04 Default Handover Zone Type 288 1 Zone Pulse Count 289 0 Zone Pulse Count Time 290 0 Zone Options 1 291 1 Zone Options 2 292 14 Zone Report Options 294 1 Zone 05 Default Instant Zone Type 295 0 Zone Pulse Count 2...

Страница 95: ...unt Time 311 0 Zone Options 1 312 1 Zone Options 2 313 12 Zone Report Options 315 1 Zone 08 Default 24 hr Tamper Zone Type 316 9 Zone Pulse Count 317 0 Zone Pulse Count Time 318 0 Zone Options 1 319 1 Zone Options 2 320 12 Zone Report Options 322 1 Zone 09 Default Not used Zone Type 323 15 Zone Pulse Count 324 0 Zone Pulse Count Time 325 0 Zone Options 1 326 1 Zone Options 2 327 14 Zone Report Opt...

Страница 96: ... 12 Default Not used Zone Type 344 15 Zone Pulse Count 345 0 Zone Pulse Count Time 346 0 Zone Options 1 347 1 Zone Options 2 348 14 Zone Report Options 350 1 Zone 13 Default Not used Zone Type 351 15 Zone Pulse Count 352 0 Zone Pulse Count Time 353 0 Zone Options 1 354 1 Zone Options 2 355 14 Zone Report Options 357 1 Zone 14 Default Not used Zone Type 358 15 Zone Pulse Count 359 0 Zone Pulse Coun...

Страница 97: ...2 376 14 Zone Report Options 378 1 The Solution 2000 control panel supports up to 8 zones The Solution 3000 control panel supports up to 16 zones Zone 9 16 can only be used in Solution 3000 control panels when the EOL Resistor Value is set as 14 or 15 Zone Types The zone types are listed in the table below Zone Type Description 0 Instant 1 Handover 2 Delay 1 3 Delay 2 4 Reserved 5 Reserved 6 24 Ho...

Страница 98: ...Code 130 has a delay time determined by the value in Locations 466 and 467 refer to Entry Time 1 page 134 After Entry Time expires the system activates an alarm If a Delay 1 Zone is not restored when the system is disarmed a Zone Restore Report is automatically sent to the receiving party 3 Delay 2 Zone A Delay 2 Zone Contact ID Event Code 130 has a delay time determined by the value in Locations ...

Страница 99: ... the horn speaker to indicate this type of alarm This fire sound is completely different from the burglary sound A 24 Hour Fire zone does not send a Restore Report until the zone is restored 14 Chime Zone A Chime Zone is not a burglary zone It can never sound the sirens or transmit reports Its purpose is to map the zone to a programmable output refer to 4 5 Global Chime in Output Event Types page ...

Страница 100: ...t time options 0 to 7 have a zone loop response time of 20 ms and options 8 to 15 have a zone loop response time of 150 ms Loop response time is the length of time a zone must be unsealed before it can register as a valid pulse Inertia sensors should use options 0 to 7 and PIR detectors should use options 8 to 15 Zone Options 1 This location has four programming options You can select any combinat...

Страница 101: ...same arming cycle only the first Zone Alarm Report can be delayed 4 Silent Alarm Select this option to program a zone as silent A silent zone does not activate the horn speaker bell or strobe outputs It activates the Silent Alarm output The report and all other programmable outputs function according to the parameters programmed for the zone 8 Sensor Watch Sensor watch allows the control panel to ...

Страница 102: ...s the system automatically sends a Zone Bypass Report when the zone is selected to be isolated All non 24 Hour zones send a Bypass Report only when the system is armed 4 Forced Arming Allowed If this option is selected the system can be armed with the zone unsealed If this option is not selected the system does not allow the User Code holder to arm the system until the zone is sealed or manually i...

Страница 103: ...de1 or STAY Mode 2 The system is disarmed from AWAY Mode STAY Mode 1 or STAY Mode 2 when using the latching keyswitch input Arming the system is not permitted from the Keyswitch Zone 4 Latching Arm and Disarm in STAY Mode 1 The system is armed or disarmed in STAY Mode 1 when using the latching keyswitch input Arming and disarming the system in AWAY Mode is not permitted from the Keyswitch Zone 5 L...

Страница 104: ...or STAY Mode 2 or arming and disarming the system from AWAY Mode is not permitted from the Keyswitch Zone Wiring Diagram for Keyswitch Zone Wiring Diagram for Keyswitch Zone Using Split EOL with Tamper 1 2 Z1 COM Z2 Z1 COM Z2 1 2 1 EOL 2 Keyswitch Momentary Toggle 1 EOL 2 Keyswitch Momentary Toggle Table 13 2 Wiring Diagram for Keyswitch Zone Zone Source Zone source is a new feature for zone progr...

Страница 105: ... Shutdown Count For Report 0380 1 15 Number of times report operates until lockout 6 Location 380 determines the number of times the zone alarm report can be activated before lockout options take effect This location has no effect unless you program at least one zone for lockout report Refer to Zone Options 1 page 100 for more information Only alarms activated from zone inputs can increment the Sw...

Страница 106: ...only for Solution 3000 Item Location Option Default New STAY Mode 2 Automatically Bypass Zones 0381 1 Zone 1 2 Zone 2 4 Zone 3 8 Zone 4 0 0382 1 Zone 5 2 Zone 6 4 Zone 7 8 Zone 8 0 0383 1 Zone 9 2 Zone 10 4 Zone 11 8 Zone 12 0 0384 1 Zone 13 2 Zone 14 4 Zone 15 8 Zone 16 0 Zone Status Reporting Options Item Location Option Default New Zone Status Reporting Options 0392 0 No Zone status reports all...

Страница 107: ...act ID Event Code 381 is sent to the base station receiver when the wireless receiver has not received a signal from any RF wireless zone during the RF Supervision Time This report continues to be sent according to the frequency of the RF Supervision Time until the fault is corrected To clear the fault and stop additional reporting Unseal and reseal the zone that registered the fault Notice If RF ...

Страница 108: ... programmed in Location393 the codepad zone indicator lights as unsealed RFID RF keyfob RFID Locations 1500 to 1817 are for RF keyfob IDs RFID is a 9 digit numbers you can find on the keyfob Control panel stores eight digits for each keyfob ID Last digit of keyfob ID is a checksum RF device RFID Locations 1820 to 1978 are for RF Zone device IDs and the RF zone input options Locations for the input...

Страница 109: ...657 0 Keyfob 17 1660 1667 0 Keyfob 18 1670 1677 0 Keyfob 19 1680 1687 0 Keyfob 20 1690 1697 0 Keyfob 21 1700 1707 0 Keyfob 22 1710 1717 0 Keyfob 23 1720 1727 0 Keyfob 24 1730 1737 0 Keyfob 25 1740 1747 0 Keyfob 26 1750 1757 0 Keyfob 27 1760 1767 0 Keyfob 28 1770 1777 0 Keyfob 29 1780 1787 0 Keyfob 30 1790 1797 0 Keyfob 31 1800 1807 0 Keyfob 32 1810 1817 0 RF Device RFID Item Location Default New R...

Страница 110: ...em Option RF Zone Option 0 All Used 1 Input 1 2 Input 2 4 Input 3 8 Input 4 Table 14 1 RF Zone Options RF Reapter RFID Item Location Default New Item Location Default New Repeater 01 1980 1987 0 Repeater 02 1990 1997 0 Repeater 03 2000 2007 0 Repeater 04 2010 2017 0 Repeater 05 2020 2027 0 Repeater 06 2030 2037 0 Repeater 07 2040 2047 0 Repeater 08 2050 2057 0 14 5 3 110 en RF Information Control ...

Страница 111: ...ault to report only to Receiver 1 Access Denied Item Location Option Default New Code retry limit 0424 0 Unlimited 1 15 Error code attempts 6 An Access Denied Report Contact ID Event Code 461 is sent to the base station receiver when the number of incorrect code attempts equals the number programmed in Location 424 An Access Denied Alarm is audible but you can program the alarm as silent by select...

Страница 112: ...4 backup 7 Report to Receiver 1 2 backup and Receiver 3 4 backup 1 Location 427 is set by default to report only to Receiver 1 Test Reporting Time Item Location Option Default New Hour of day tens digit 0428 0 Hour of day units digit 0429 0 Minute of day tens digit 0430 0 Minute of day units digit 0431 0 Repeat interval in days 0434 0 Disable 1 15 1 15 days 0 A Test Report Contact ID Event Code 60...

Страница 113: ...t Contact ID Event Code 573 is sent at the end of Exit Time for any zone that was manually isolated A 24 Hour Zone sends a Zone Bypass Report when the zone is selected to be isolated A Zone Bypass Restore Report is sent when the system is disarmed All bypassed zones are automatically cleared when the system is disarmed Notice A 24 Hour Fire Zone that is manually bypassed reports as Contact ID Even...

Страница 114: ...eiver Missing RF Low Battery Report An RF Low Battery Report Contact ID Event Code 384 is sent to the base station receiver when the battery voltage on a wireless zone falls below its corresponding low battery condition An RF Low Battery Restore Report is sent on the first valid signal after the battery is replaced Arm Disarm Reports A Disarm Report Contact ID Event Code 401 is sent to the base st...

Страница 115: ...ent Code 110 is sent to the base station receiver when a user presses 4 and 6 at the same time A Fire Alarm is audible but you can program the alarm as silent by selecting Option 2 in Location 493 A distinct fire sound is emitted through the horn speaker to indicate this type of alarm The fire sound is different than the burglary sound Restore Reports are not sent for this event Codepad Medical Re...

Страница 116: ...tion receiver when the system s battery voltage falls below 11 VDC or when a Dynamic Battery Test detects a low capacity battery The control panel continually monitors the battery voltage A Dynamic Battery Test is done every time the system is armed and every 4 hours after the control panel is powered up Low Battery Restore Report A Low Battery Restore Report is sent if the backup battery is resto...

Страница 117: ...ters determine how long and how often the output operates Table 16 1 Output Parameters Output Programming Item Location Default New Item Location Default New Output 1 Default Horn Speaker Output 2 Default Fire Alarm With Verification Event Code 0436 1 Event Code 0442 2 Event Code 0437 14 Event Code 0443 7 Polarity 0438 0 Polarity 0444 10 Time Base 0439 0 Time Base 0445 2 Time Base Multiplier 0440 ...

Страница 118: ...Item Location Default New Polarity 0462 2 Time Base 0463 1 Time Base Multiplier 0464 0 Time Base Multiplier 0465 9 118 en Programmable Outputs Control Panel 2017 10 03 F 01U 298 026 Installation Guide Bosch Security Systems Inc ...

Страница 119: ...tiplier 0668 0 Time Base Multiplier 0663 0 Time Base Multiplier 0669 0 B308 Output 5 B308 Output 6 Event Code 0670 0 Event Code 0676 0 Event Code 0671 0 Event Code 0677 0 Polarity 0672 0 Polarity 0678 0 Time Base 0673 0 Time Base 0679 0 Time Base Multiplier 0674 0 Time Base Multiplier 0680 0 Time Base Multiplier 0675 0 Time Base Multiplier 0681 0 B308 Output 7 B308 Output 8 Event Code 0682 0 Event...

Страница 120: ...t 14 Event Code 0718 0 Event Code 0724 0 Event Code 0719 0 Event Code 0725 0 Polarity 0720 0 Polarity 0726 0 Time Base 0721 0 Time Base 0727 0 Time Base Multiplier 0722 0 Time Base Multiplier 0728 0 Time Base Multiplier 0723 0 Time Base Multiplier 0729 0 B308 Output 15 B308 Output 16 Event Code 0730 0 Event Code 0736 0 Event Code 0731 0 Event Code 0737 0 Polarity 0732 0 Polarity 0738 0 Time Base 0...

Страница 121: ... 1 4 AC fail 1 5 Low battery 1 6 Output 1 fail 1 7 Sensor watch alarm 1 8 Codepad medical alarm 1 9 Codepad fire alarm 1 10 Codepad panic alarm 1 11 Codepad duress alarm 1 12 Access denied code retries 1 13 Reserved 1 14 Horn speaker output 1 only 1 15 Siren running Event Code 2 0 Strobe 2 1 Silent alarm 2 2 Alarm in STAY mode 2 3 Alarm in AWAY mode 2 4 System fault 2 5 Fire alarm resetting 2 6 Fi...

Страница 122: ...5 6 14 Remote control 16 6 15 Remote control 17 7 0 Remote control 18 7 1 Remote control 19 7 2 Remote control 20 7 3 Remote control 21 7 4 Remote control 22 Polarity Modes 0 Output not used 1 Normally open going low 2 Normally open pulsing low 3 Normally open one shot low 4 Normally open one shot low reactivate 5 Normally open one shot low can reset 6 Normally open one shot low alarm 7 Normally o...

Страница 123: ...put Event Type Program these numbers into the appropriate locations for the output Notice All reset times reference Polarity 1 and 8 Reset times vary depending on the selected polarity 0 1 System Armed This output operates when the system is armed The output is reset when the system is disarmed If the system is partitioned this output operates when both areas are armed in AWAY Mode STAY Mode 1 or ...

Страница 124: ... follow the Entry Guard Time 0 12 Entry Warning Day Alarm Resetting This output combines Entry Warning and Day Alarm Resetting so that either of these two events activates the output If the output is activated by Entry Timer 1 Entry Timer 2 or Entry Guard Timer for STAY Mode the output is reset when the Entry Time or Entry Guard Time expires or the system is disarmed If a zone programmed for Day A...

Страница 125: ...cator Menu 3 4 4 is enabled 1 2 Kiss off Received This output operates after the control panel successfully transmitted to the receiving party or else the output is reset 1 3 AUX Power Supply Fail This output operates when the 12V SDI2 BUS devices power supply or 12V zone or output AUX power supply fails The output is reset when all fault AUX power supply above is reset 1 4 AC Fail This output ope...

Страница 126: ...s Running This output operates for the duration of the Siren Run Time programmed in Location 479 When the sirens are activated this output is reset when the Siren Run Time expires The relay output Output 4 is set by default for this operation 2 0 Strobe Operating This output operates when an alarm occurs and is reset when a valid User Code is entered The strobe output Output 3 is set by default fo...

Страница 127: ...sing the master code function or A Link software or Smartphone App RSC to turn remote output 1 on The output is reset when using the master code function or A Link software or Smartphone App RSC to manually turn remote output 1 off or automatically turn remote output 1 off when the ON time expires if output polarity is from 3 to 6 or from 10 to 13 2 9 Remote Control 2 This output operates output w...

Страница 128: ...unications Failure after Three Unsuccessful Calls This output operates after the communicator makes three unsuccessful calls to any one used receiver The output is reset when all messages are transmitted or six unsuccessful or no calls to used receivers 3 0 Communications Failure This output operates when either of the communication routes fault The output is reset when both route faults clear 3 1...

Страница 129: ...urns to 50 Hz Notice Output Event Types 4 10 through 6 1 are available only to partitioned control panels 4 10 Area 1 Has Unsealed Zone 4 11 Area 2 Has Unsealed Zone These two outputs operate when a zone in their corresponding area registers as unsealed either when the area is armed in AWAY Mode or STAY Mode or the area is disarmed There are some conditions for the zone the zone type is valid and ...

Страница 130: ...mote Control 14 6 13 Remote Control 15 6 14 Remote Control 16 6 15 Remote Control 17 7 0 Remote Control 18 7 1 Remote Control 19 7 2 Remote Control 20 7 3 Remote Control 21 7 4 Remote Control 22 These outputs operate output when using the master code function or A Link software or Smartphone App RSC to turn remote output on The output is reset when using the master code function or A Link software...

Страница 131: ...on 7 Normally Open Latching Low This polarity is normally open circuit and switches to 0 V when the event occurs The output switches back to open circuit when a user holds down 7 on the remote codepad until two beeps sound Time parameters do not apply to this polarity 8 Normally Low Going Open This polarity is normally 0 V and switches to open circuit when the event occurs The output switches back...

Страница 132: ...om 00 to 99 For greater accuracy use 60 sec for 1 min intervals and 60 min for 1 hour intervals Pulsing Polarities When programming pulsing polarities you must set both the On and Off times The duration or On time for an output is determined by time base In other words there are only four possible On times The Off time is calculated by multiplying the On time by a decimal number between 00 and 99 ...

Страница 133: ... 19 8 sec 200 ms 200 ms 1 to 99 sec 1 sec 1 sec 1 to 99 min 1 min 1 min 1 to 99 hr 1 hr 1 hr Table 16 4 One Shot Time Settings Control Panel Programmable Outputs en 133 Bosch Security Systems Inc Installation Guide 2017 10 03 F 01U 298 026 ...

Страница 134: ...Time 1 from 0 to 255 sec in increments of 1 sec Entry Time 1 is the delay time used by the Delay 1 Zones See also Zone Types page 97 Entry Time 2 Item Location Option Default New Increments of 1 sec 0 to 15 sec 0468 8 Increments of 16 sec 0 to 240 sec 0469 2 You can program Entry Time 2 from 0 to 255 sec in increments of 1 sec Entry Time 2 is the delay time used by Delay 2 Zones Exit Time Item Loc...

Страница 135: ...panel clears the communicator buffer and does not report the alarm to the receiving party See also Zone Options 1 page 100 Sensor Watch Time Item Location Option Default New Increments of days tens digit 0476 0 Increments of days units digit 0477 0 The time set in these two locations determines the number of days 0 to 99 a zone can remain sealed before registering as a fault This feature is active...

Страница 136: ...und Rate does not change the frequency of the fire alarm tone Auto Arming Pre Alert Time Item Location Option Default New Auto Arming Pre Alert Time 0481 0 No alert time 1 15 Alert time 5 75 min increments of 5 min 1 This location sets the time period during which the control panel warns you it is automatically armed in AWAY Mode The codepad beeps once every second until the Pre Alert Timer expire...

Страница 137: ...ion Option Default New Hour of the day tens digit 0486 0 Hour of the day units digit 0487 0 Minute of the day tens digit 0488 0 Minute of the day units digit 0489 0 These locations specify the time of day the system automatically disarms itself Set this time in 24 hour format for example program 10 30 PM as 2230 User Code 997 is reported when this feature is used For partitioned control panels bot...

Страница 138: ...program the number of times the zone can report before being locked out 2 Warning Device Output1 3 Monitor If this option is selected the control panel detects when Output1 3 Event Type programmed as a Warning Device Horn speaker Siren Running Strobe is disconnected from the terminals The FAULT indicator lights when the Warning Device is disconnected and is extinguished when the Warning Device is ...

Страница 139: ... a Codepad Medical Alarm is activated when a user presses 7 and 9 at the same time on the remote codepad Selecting this option does not affect the operation of the communication report 8 Access Denied Code Retries to Be Silent If this option is selected a Codepad PIN Error Alarm does not operate the horn speaker bell or the strobe outputs If this option is not selected all three outputs operate af...

Страница 140: ...he sequence is broken before the Entry Time expires an alarm occurs If this option is not selected handover delay follows the entry path if a Delay Zone is activated first Refer to Zone Types page 97 for more information about Handover Zones and Delay Zones Example Program zone 1 as Delay Zone and zone 2 and 3 as Handover Zone When the Handover Delay to Be Sequential is selected and the zone 1 is ...

Страница 141: ...m Location Option Default New Consumer Options 1 0496 1 Test reports only when armed 2 Test report after siren reset 4 Auto arm in STAY Mode 1 8 STAY indicator to display day alarm status 0 1 Test Reports Only When Armed If this option is selected Test Reports Contact ID Event Code 602 are only sent when the system is armed It is no longer necessary to send a Test Report with an Arm Disarm Report ...

Страница 142: ...is selected all indicators on the codepad display are extinguished if a button is not pressed for 60 sec The indicators lights again when there is an alarm except a silent alarm when a button is pressed on the codepad when the AC MAINS fail beeps or if the Entry Timer is activated 2 Single Button Arming Allowed If this option is selected the hold down functions for arming in AWAY Mode STAY Mode 1 ...

Страница 143: ... FAULT indicator flashes when a new fault occurs and the codepad does not beep once every minute 2 Digit 3 for Codepad Duress Instead of 9 If this option is selected a user can add 3 instead of a 9 to the code used to disarm the system to activate a Duress Alarm 4 Alarms Activate Sirens and Strobe Outputs in STAY Modes 1 and 2 Select this option if audible alarms are required when the system is ar...

Страница 144: ...orts for each area an Arm Report is sent only after both areas are armed and a Disarm Report is sent as soon as one area is disarmed The reports are sent with the User Codes allocated to the specific area You must allocate the user codes to the specific area and program user codes to have a priority level set with no arm disarm reports Notice This option is applicable only when all User Codes have...

Страница 145: ...e can only operate the assigned area on this area s codepad For user code and authority level refer to User Code Priority page 89 Example Two methods to arm disarm both areas at the same time User Code 0 this method requires to allocate the same user code to both areas as a common user code then you can arm disarm both areas at the same time with any area codepad Refer to Arm or Disarm both Areas ...

Страница 146: ...les the wired zones allocated to the same numbers cannot respond anymore See also Zone Programming page 93 RF Device RFID page 109 Codepad assignment Item Location Default New Item Location Default New Codepad 1 Area 0518 1 Codepad 2 Area 0519 0 Codepad 3 Area 0520 0 Codepad 4 Area 0521 0 Option 0 Codepad area not assigned 1 Codepad assigned to Area 1 2 Codepad assigned to Area 2 3 Codepad assigne...

Страница 147: ...to Area 2 3 User code assigned to both Area 1 and Area 2 Locations 534 to 565 are used to assign each User Code to one or two area areas of a partitioned Control Panel Enter a value from 0 to 3 into each of these locations to assign the User Code holder to the areas it must operate You can allocate multiple User Codes to the same area User codes and RF user codes can share the same user code numbe...

Страница 148: ...rom location 2500 to 2535 as home message And you can edit up to 12 alphanumeric for per zone name and user name from location 2536 to 3687 Notice Instead of TEXT codepad edit text via A Link Plus is more convenient 20 148 en Text Information Control Panel 2017 10 03 F 01U 298 026 Installation Guide Bosch Security Systems Inc ...

Страница 149: ......

Страница 150: ......