background image

 

 

 

 

 

Control Panel

Solution 2000 / 3000

 

 

en

Quick Reference Guide

 

Содержание Solution 2000

Страница 1: ...Control Panel Solution 2000 3000 en Quick Reference Guide ...

Страница 2: ......

Страница 3: ...al Network Module 22 4 1 4 Password for A Link Plus RSC Connection 23 4 1 5 DTMF Timing Compensation 23 4 1 6 Country Codes 23 4 1 7 Telco Arming Sequence Call Forward On 23 4 1 8 Telco Disarm Sequence Call Forward Off 23 4 1 9 Call Back Telephone Number 23 4 1 10 Ring Count 23 4 1 11 Telephone Line Fail Options 24 4 1 12 Communication Options 1 24 4 1 13 Communication Options 2 24 4 1 14 Communic...

Страница 4: ...n Time 40 4 14 9 Siren Sound Rate 40 4 14 10 Auto Arming Pre Alert Time 40 4 14 11 Auto Arming Time 40 4 14 12 Auto Disarming Time 41 4 14 13 Kiss Off Wait Time 41 4 14 14 Speaker Beep Volume 41 4 15 Options Programming 41 4 15 1 System Options 1 41 4 15 2 System Options 2 41 4 15 3 System Options 3 42 4 15 4 System Options 4 42 4 15 5 Consumer Options 1 42 4 15 6 Consumer Options 2 42 4 15 7 Cons...

Страница 5: ... 5 Appendices 48 5 1 Connections for EOL Resistors 48 5 2 Wiring Diagram 49 5 3 Component Overlay 50 5 4 Codepad Address Setting 51 Control Panel Table of Contents en 5 Bosch Security Systems Inc Quick Reference Guide 2015 06 03 F 01U 298 027 ...

Страница 6: ... Keyfobs WE800EV2 required 21 21 RADION RFKF Keyfobs RADION B810 required 0 32 Number of areas partitions 2 2 Number of zones inputs 4 4 ZD 8 8 ZD Number of Onboard outputs 4 4 Number of text LCD codepads IUI SOL TEXT or ICON LCD codepads IUI SOL ICON 4 4 Number of Touchscreen codepads IUI SOL 4TS or IUI SOL 7TS 1 1 Number of wireless receiver WE800EV2 1 1 Number of RADION receiver B810 0 1 Number...

Страница 7: ... programming item setting Press or press and hold for 3 seconds to exit programming without saving changes Operate according to the menu prompt Select menu and enter or select data for specific programming items to complete programming step by step For specific items and options refer to Programming Parameters page 20 4 After completing input press to get back to the previous menu Complete all pro...

Страница 8: ...arm enable 3 Disarmed on power up 4 Arm disarm track on power up 5 Phone remote arm 6 Answer machine bypass on arm 7 Ignore AC fail 1 AC fail report wait time 2 Warning device fault monitor 3 Phone line fault indicator 4 Phone line fault alarm on armed 5 Phone line fault alarm on disarm 6 Lockout phone line fail alarm 7 RF receiver 1 Zone RFID and input option 2 Keyfob RFID 3 Repeater RFID 4 RF su...

Страница 9: ... Subscriber ID number 4 IP Port Email Conettix ACK wait time Conettix heart beat time Conettix anti replay enable 5 CSVIP user name and password 6 Ring count 1 Report function enable 2 Exit A Link connection on alarm 3 System status report option 4 Use bell 103 for FSK format 5 DTMF dial pulse to 1 digit sec 6 Set up domestic dialing format DTMF timing compensation 111 7 Swing shutdown 8 Zone opti...

Страница 10: ...tion The data in the next location is displayed using the codepad indicators For example if you are currently positioned at Location 0034 pressing key takes you to Location 0035 To step back one location press the key For example if you are currently positioned at Location 0035 pressing the key returns to Location 0034 To change data in the current location enter the new value 0 to 15 followed by ...

Страница 11: ...ler Programming Commands displayed in below table can only be used when you enter Installer s Programming Mode Enter the command followed by the key Command Description 958 Exit from Installer s Programming Mode without saving changes 959 Test IUI SOL ADAPTER 960 Exit from Installer s Programming Mode with saving changes and system reset 961 Reset the control panel to factory defaults 962 Copy the...

Страница 12: ...irst Test Report I Code 3 Change Telco Arm Disarm Sequence U Code 2 Change Domestic Phone Number I Code 4 Setting STAY Mode 2 Zones U Code 3 Change Telco Arm Disarm Sequence I Code 5 Turn Output On Off U Code 4 Setting STAY Mode 2 Zones I Code 6 Setting the Date and Time U Code 6 Enable Report Monitor Mode I Code 7 Walk Test Mode U Code 7 Walk Test Mode I Code 8 Event Memory Recall Mode U Code 8 E...

Страница 13: ...e AUI 7 9 Codepad Medical Alarm AUI Hold down 6 3sec Initiate a Modem Call AUI Codepad Panic Alarm AUI Hold down 7 3sec Reset Latching Output AUI Hold down 8 Change the Codepad Buzzer Tone and Codepad Area Display AUI Other Command Function Description Access Hold down 9 3sec Send Test Report AUI Zone Bypass U Hold down 3sec Arm the system in AWAY Mode AUI Enter General Menu text codepad only AUI ...

Страница 14: ...followed by 0 and the key 2 Enter the Device Number 1 to 16 you want to delete followed by the key 3 Press the key to delete the RF device Add Delete RF Repeater Notice The Solution 2000 control panel does not support RF repeaters Add RF Repeater Set RF receiver as RADION Receiver 1 Enter the Installer Code followed by 0 and the key for example 12340 2 Enter the point ID of RADION Repeater 822 to ...

Страница 15: ...WE800EV2 keyfob number 301 to 332 you want to delete followed by the key 3 Press the key to delete the WE800EV2 Keyfob Add RADION Keyfob Set RF receiver as RADION Receiver 1 Enter the Installer Code followed by 0 and the key for example 12340 2 Enter the RADION keyfob number 301 to 332 you want to add 301 keyfob 1 302 keyfob2 etc followed by the key Up to 32 RADION keyfobs can be added but only cu...

Страница 16: ... Press the key to exit Telco Disarm Sequency Call Forward Off 1 Enter the Installer Code or Master Code followed by 3 and the key 2 Press 2 followed by the key 3 Enter the Call Forward Off sequence 4 Press the key to exit Set STAY Mode 2 Bypass Zones 1 Enter the Installer Code or Master Code followed by 4 and the key 2 Enter the Zone Number you want the system to automatically isolate followed by ...

Страница 17: ...estored Pressing the button once acknowledges the fault and stops the codepad from beeping once every min How to Determine the Type of System Fault To determine which system fault occurred enter Fault Analysis Mode by following the steps below 1 Hold down the 5 key until two beeps sound The STAY and AWAY indicators flash in unison A zone indicator displays the type of fault that occurred for examp...

Страница 18: ...em Fault A system fault only displays when any of the following faults occur After entering Fault Analysis Mode press the 1 key to determine which of the following faults occurred Low Battery Fault A low battery fault registers when the system detects a low capacity back up battery The system automatically performs a battery test every four hours and every time you arm the system Date and Time The...

Страница 19: ...until two beeps sound This displays the zone reporting the sensor watch fault 5 RF Sensor Missing An RF sensor missing fault registers because one or more RF detection devices fails to communicate to the RF radio receiver for the time period programmed by your installer The fault clears once the RF device in question successfully transmits to the RF radio receiver Press the 5 key until two beeps s...

Страница 20: ...er ID Number 0034 0039 0 IP Port Email 1000 1099 CSVIP User Name and Password 1100 1163 Conettix Anti replay 1400 1 Anti replay for Receiver 1 Enable 2 Anti replay for Receiver 2 Enable 4 Reserved 8 Reserved 3 Conettix ACK Wait Time 1401 1402 0 99 0 99 sec 5 Conettix Heart Beat Time 1403 1404 1 99 1 99 min 1 Receiver 2 Item Location Option Default New Phone Number 1 0040 0055 15 Telephone terminat...

Страница 21: ...ceiver 2 2 Select Comm Receiver Config Subscriber ID Number enter Subscriber ID Number 3 Select Comm Network Config select module 1 or 2 as Use do not configure 4 Select Comm Receiver Config IP Port Email enter IP and the Port for example 192 168 226 17 12000 5 Select Comm Receiver Config CSVIP User Name And Password enter CSVIP User Name and Password Both user name and password enter as user name...

Страница 22: ...s Enable in A Link Plus if access to network module via the web interface is still needed 1 Select Comm Receiver Config Transmit Format select Email 2 Select Comm Receiver Config Subscriber ID Number enter Email title with consist of 6 numbers 3 Selec Comm Network Config select module 1 or 2 as Use and configure 4 Select Comm Receiver Config IP Port Email enter email address of the recipient 5 Sel...

Страница 23: ...3 0142 15 Telephone termination 15 Telco Disarm Sequence Call Forward Off Item Location Option Default New Telco Disarm Sequence 0143 0158 15 Telephone termination 15 Call Back Telephone Number Item Location Option Default New Call Back Telephone Number 0159 0174 15 Telephone termination 15 Ring Count Item Location Option Default New Ring Count 0175 0 Panel does not answer 1 13 No of rings until p...

Страница 24: ...d 4 Answering machine bypass only when armed 8 Use Bell 103 for FSK format Disabled CCITT V21 9 Communication Options 2 Item Location Option Default New Communication Options 2 0178 1 Arm Disarm Reports only if alarmed 2 STAY Mode Arm Disarm Reports Enable 4 Delay siren until transmission complete 8 Extend handshake wait time from 30 to 60 sec 0 Communication Options 3 Item Location Option Default...

Страница 25: ...r 01 0185 0186 0187 0188 2 5 8 0 0189 10 User 02 0190 0193 15 0194 2 User 03 0195 0198 15 0199 2 User 04 0200 0203 15 0204 2 User 05 0205 0208 15 0209 2 User 06 0210 0213 15 0214 2 User 07 0215 0218 15 0219 2 User 08 0220 0221 0223 0 15 0224 3 User 09 0225 0228 15 0229 2 User 10 0230 0233 15 0234 2 User 11 0235 0238 15 0239 2 User 12 0240 0243 15 0244 2 User 13 0245 0248 15 0249 2 User 14 0250 025...

Страница 26: ...635 2 User 31 0636 0639 15 0640 2 User 32 0641 0644 15 0645 2 Authority Levels Description 0 Arm Disarm 1 Arm Only 2 Arm Disarm and Arm Disarm Reports 3 Arm Only and Arm Reports 4 Arm Disarm and Code Required to Isolate 6 Arm Disarm and Arm Disarm Reports and Code Required to Isolate 8 Master Code and Arm Disarm 10 Master Code and Arm Disarm and Arm Disarm Reports 12 Master Code and Arm Disarm and...

Страница 27: ...75 0 Zone Pulse Count Time 0269 0 Zone Pulse Count Time 0276 0 Zone Options 1 0270 1 Zone Options 1 0277 1 Zone Options 2 0271 14 Zone Options 2 0278 14 Reserved 0272 Reserved 0279 Zone Report Options 0273 1 Zone Report Options 0280 1 Zone 03 Zone 04 Zone Type 0281 1 Zone Type 0288 1 Zone Pulse Count 0282 0 Zone Pulse Count 0289 0 Zone Pulse Count Time 0283 0 Zone Pulse Count Time 0290 0 Zone Opti...

Страница 28: ...315 1 Zone Report Options 0322 1 Zone 09 Zone 10 Zone Type 0323 15 Zone Type 0330 15 Zone Pulse Count 0324 0 Zone Pulse Count 0331 0 Zone Pulse Count Time 0325 0 Zone Pulse Count Time 0332 0 Zone Options 1 0326 1 Zone Options 1 0333 1 Zone Options 2 0327 14 Zone Options 2 0334 14 Reserved 0328 Reserved 0335 Zone Report Options 0329 1 Zone Report Options 0336 1 Zone 11 Zone 12 Zone Type 0337 15 Zon...

Страница 29: ... Options 0371 1 Zone Report Options 0378 1 For zone item options refer to below Zone Item Options Item Option Zone Type 0 Instant 1 Handover 2 Delay 1 3 Delay 2 4 Reserved 5 Reserved 6 24 Hour Medical 7 24 Hour Panic 8 24 Hour Hold up 9 24 Hour Tamper 10 Reserved 11 Keyswitch 12 24 Hour Burglary 13 24 Hour Fire 14 Chime Only 15 Not used Zone Pulse Count Use the pulse count to program how many puls...

Страница 30: ... Latching arm in STAY Mode 1 6 Latching disarm from STAY Mode 8 Momentary arm and disarm in AWAY Mode 9 Momentary arm in AWAY Mode 10 Momentary disarm from AWAY Mode or STAY Mode 12 Momentary arm and disarm in STAY Mode 1 13 Momentary arm in STAY Mode 1 14 Momentary disarm from STAY Mode Table 4 3 Zone Item Options The keyswitch zone options replace Zone Options 1 only for the zones that were prog...

Страница 31: ...8 Zone 16 0 Notice Solution 2000 supports zone 1 8 only Zone Status Reporting Options Item Location Option Default New Zone Status Reporting Options 0392 0 No Zone status reports allowed 1 Report to Receiver 1 2 Report to Receiver 2 4 Report to both Receiver 1 and Receiver 2 8 Report to Receiver 2 only Receiver 1 fails 1 RF Programming RF Supervision Time Item Location Option Default New RF Superv...

Страница 32: ...ng Arm Disarm Reporting Options Item Location Option Default New Arm Disarm Reporting Options 0403 0 No Arm Disarm Reports allowed 1 Report to Receiver 1 2 Report to Receiver 2 4 Report to both Receiver 1 and Receiver 2 8 Report to Receiver 2 only if Receiver 1 fails 1 Codepad Reporting Options Item Location Option Default New Codepad Reporting Options 0411 0 No Codepad Alarm Reports allowed 1 Rep...

Страница 33: ... Report Time Automatic Item Location Option Default New Hour of day tens digit 0428 0 Hour of day units digit 0429 0 Minute of day tens digit 0430 0 Minute of day units digit 0431 0 Repeat interval in days 0434 0 Disable 1 15 1 15 days 0 Test Reporting Options Item Location Option Default New Test Reporting Options 0435 0 No report required 1 Report to Receiver 1 2 Report to Receiver 2 4 Report to...

Страница 34: ... Strobe Reset After 8 hrs Relay Output Default Sirens Running Event Code 0448 2 Event Code 0454 1 Event Code 0449 0 Event Code 0455 15 Polarity 0450 6 Polarity 0456 1 Time Base 0451 4 Time Base 0457 0 Time Base Multiplier 0542 0 Time Base Multiplier 0458 0 Time Base Multiplier 0453 8 Time Base Multiplier 0459 0 Codepad Buzzer Default Entry Exit Warning and Day Alarm Event Code 0460 0 Event Code 04...

Страница 35: ...plier 0668 0 Time Base Multiplier 0663 0 Time Base Multiplier 0669 0 B308 Output 5 B308 Output 6 Event Code 0670 0 Event Code 0676 0 Event Code 0671 0 Event Code 0677 0 Polarity 0672 0 Polarity 0678 0 Time Base 0673 0 Time Base 0679 0 Time Base Multiplier 0674 0 Time Base Multiplier 0680 0 Time Base Multiplier 0675 0 Time Base Multiplier 0681 0 B308 Output 7 B308 Output 8 Event Code 0682 0 Event C...

Страница 36: ...ier 0711 0 Time Base Multiplier 0717 0 B308 Output 13 B308 Output 14 Event Code 0718 0 Event Code 0724 0 Event Code 0719 0 Event Code 0725 0 Polarity 0720 0 Polarity 0726 0 Time Base 0721 0 Time Base 0727 0 Time Base Multiplier 0722 0 Time Base Multiplier 0728 0 Time Base Multiplier 0723 0 Time Base Multiplier 0729 0 B308 Output 15 B308 Output 16 Event Code 0730 0 Event Code 0736 0 Event Code 0731...

Страница 37: ...ess denied code retries 1 13 Reserved 1 14 Horn speaker output 1 only 1 15 Siren running Event Code 2 0 Strobe 2 1 Silent alarm 2 2 Alarm in STAY mode 2 3 Alarm in AWAY mode 2 4 System fault 2 5 Fire alarm resetting 2 6 Fire alarm latching 2 7 Fire alarm verification 2 8 Remote control 1 2 9 Remote control 2 2 10 Remote control 3 2 11 Radio control output 1 2 12 Radio control output 2 2 13 Radio c...

Страница 38: ...ontrol 15 6 14 Remote control 16 6 15 Remote control 17 7 0 Remote control 18 7 1 Remote control 19 7 2 Remote control 20 Polarity Modes 0 Output not used 1 Normally open going low 2 Normally open pulsing low 3 Normally open one shot low 4 Normally open one shot low reactivate 5 Normally open one shot low can reset 6 Normally open one shot low alarm 7 Normally open latching low 8 Normally low goin...

Страница 39: ... to 15 sec 0466 4 Increments of 16 sec 0 to 240 sec 0467 1 Entry Time 2 Item Location Option Default New Increments of 1 sec 0 to 15 sec 0468 8 Increments of 16 sec 0 to 240 sec 0469 2 Exit Time AWAY STAY Modes Item Location Option Default New Increments of 1 sec 0 to 15 sec 0470 12 Increments of 16 sec 0 to 240 sec 0471 3 Entry Guard Time For STAY Mode Item Location Option Default New Increments ...

Страница 40: ...nd Rate Item Location Option Default New Siren Sound Rate 0480 0 Slowest frequency 15 Fastest frequency 7 Auto Arming Pre Alert Time Item Location Option Default New Auto Arming Pre Alert Time 0481 0 No alert time 1 15 Alert time 5 75 min increments of 5 min 1 Auto Arming Time Item Location Option Default New Hour of the day tens digit 0482 0 Hour of the day units digit 0483 0 Minute of the day te...

Страница 41: ...ystem Options 1 0492 1 Bosch Security Systems smart lockout allowed 2 Warning device fault monitor 4 Strobe indication for radio arm disarm 8 Assign button 4 on keyfob to operate STAY Mode 1 1 Notice Option 2 is available only when the warning device such as horn speaker is connected to any of the output 1 3 System Options 2 Item Location Option Default New System Options 2 0493 1 Codepad panic to...

Страница 42: ...Mode 1 8 STAY indicator to display day alarm status 0 Consumer Options 2 Item Location Option Default New Consumer Options 2 0497 1 Codepad displays extinguish after 60 sec 2 Single button arming allowed AWAY STAY Modes 1 and 2 4 Single button disarming allowed STAY Modes 1 and 2 8 Alarm memory reset on disarm 2 Consumer Options 3 Item Location Option Default New Consumer Options 3 0498 1 Codepad ...

Страница 43: ... Location Default New Zone 1 Area 0502 1 Zone 2 Area 0503 1 Zone 3 Area 0504 1 Zone 4 Area 0505 1 Zone 5 Area 0506 1 Zone 6 Area 0507 1 Zone 7 Area 0508 1 Zone 8 Area 0509 1 Zone 9 Area 0510 1 Zone 10 Area 0511 1 Zone 11 Area 0512 1 Zone 12 Area 0513 1 Zone 13 Area 0514 1 Zone 14 Area 0515 1 Zone 15 Area 0516 1 Zone 16 Area 0517 1 Option 0 Zone area not assigned 1 Zone assigned to Area 1 2 Zone as...

Страница 44: ...de 13 0546 1 User Code 14 0547 1 User Code 15 0548 1 User Code 16 0549 1 User Code 17 0550 1 User Code 18 0551 1 User Code 19 0552 1 User Code 20 0553 1 User Code 21 0554 1 User Code 22 0555 1 User Code 23 0556 1 User Code 24 0557 1 User Code 25 0558 1 User Code 26 0559 1 User Code 27 0560 1 User Code 28 0561 1 User Code 29 0562 1 User Code 30 0563 1 User Code 31 0564 1 User Code 32 0565 1 Option ...

Страница 45: ...3 1720 1727 0 Keyfob 24 1730 1737 0 Keyfob 25 1740 1747 0 Keyfob 26 1750 1757 0 Keyfob 27 1760 1767 0 Keyfob 28 1770 1777 0 Keyfob 29 1780 1787 0 Keyfob 30 1790 1797 0 Keyfob 31 1800 1807 0 Keyfob 32 1810 1817 0 Zone Device RFID and RF Zone Option Item Location Default New RF Zone Option Location Default New RF Zone 01 1820 1827 0 1828 0 RF Zone 02 1830 1837 0 1838 0 RF Zone 03 1840 1847 0 1848 0 ...

Страница 46: ...eater 03 2000 2007 0 Repeater 04 2010 2017 0 Repeater 05 2020 2027 0 Repeater 06 2030 2037 0 Repeater 07 2040 2047 0 Repeater 08 2050 2057 0 Text Codepad Items Notice Refer Program IP items with A Link Plus Software or text codepad page 21 to enter sensitive alphanumeric characters with text codepad IUI SOL TEXT Home Message Item Location Default New Home Message 2500 2535 00000 Zone Names Item Lo...

Страница 47: ...3376 3399 User 5 Name 3016 3039 User 21 Name 3400 3423 User 6 Name 3040 3063 User 22 Name 3424 3447 User 7 Name 3064 3087 User 23 Name 3448 3471 User 8 Name 3088 3111 User 24 Name 3472 3495 User 9 Name 3112 3135 User 25 Name 3496 3519 User 10 Name 3136 3159 User 16 Name 3520 3543 User 11 Name 3160 3183 User 27 Name 3544 3567 User 12 Name 3184 3207 User 28 Name 3568 3591 User 13 Name 3208 3231 User...

Страница 48: ...th tamper Location 266 14 Split EOL3k3 6k8 with tamper 1k ZONE 1 3K3 EOL ZONE 5 Solution 2000 ZONE 9 Solution 3000 6K8 EOL TAMPER N C TAMPER N C N C N C 1K0 1K0 Table 5 3 Connection 3 Double Zone input Location 266 15 Split EOL 3k3 6k8 ZONE 1 3K3 EOL ZONE 5 Solution 2000 ZONE 9 Solution 3000 6K8 EOL N C N C Table 5 4 Connection 4 5 5 1 48 en Appendices Control Panel 2015 06 03 F 01U 298 027 Quick ...

Страница 49: ...attery 12V 7Ah R B B G Y R B G Y R B G Y R B G Y 3K3 PIR Siren Smoke detector 6K8 3K3 6K8 3K3 6K8 3K3 6K8 R Y G B _ Bosch SDI2 Bus 1 2 3 900mA AUX 900mA Max 900mA I 1100mA Figure 5 1 Wiring Diagram 5 2 Control Panel Appendices en 49 Bosch Security Systems Inc Quick Reference Guide 2015 06 03 F 01U 298 027 ...

Страница 50: ...Component Overlay 1 2 3 5 5 9 10 11 12 13 14 4 6 7 8 GND c 12V Figure 5 2 Component Overlay 5 3 50 en Appendices Control Panel 2015 06 03 F 01U 298 027 Quick Reference Guide Bosch Security Systems Inc ...

Страница 51: ... Zone 1 4 and Zone 5 8 for Solution 2000 Zone 1 4 and Zone 9 12 for Solution 3000 13 LED indicator 7 Output termination strip 14 Default button Table 5 5 Callout description Codepad Address Setting DIP Switch Codepad Address DIP Switch Number 1 2 3 4 5 6 1 On Off Off Off Off On 2 Off On Off Off Off On 3 On On Off Off Off On 4 Off Off On Off Off On Table 5 6 Codepad DIP switch address setting DIP s...

Страница 52: ......

Страница 53: ......

Страница 54: ...Bosch Security Systems Inc 130 Perinton Parkway Fairport NY 14450 USA www boschsecurity com Bosch Security Systems Inc 2015 Bosch Sicherheitssysteme GmbH Robert Bosch Ring 5 85630 Grasbrunn Germany ...

Отзывы: