Auto Disarming Time
Item
Location
Option
Default New
Hour of the day (tens digit)
0486
0
Hour of the day (units digit)
0487
0
Minute of the day (tens digit)
0488
0
Minute of the day (units digit)
0489
0
Kiss-Off Wait Time
Item
Location
Option
Default New
Increments of 500 ms (500 ms to 8
sec.)
0490
3
Speaker Beep Volume
Item
Location
Option
Default New
Speaker Beep Volume
0491
0 = No Beeps
15 = Loudest Beeps
13
Options Programming
System Options 1
Item
Location
Option
Default New
System Options 1
0492
1 = Bosch Security Systems smart lockout
allowed
2 = Warning device fault monitor
4 = Strobe indication for radio arm/disarm
8 = Assign button 4 on keyfob to operate STAY
Mode 1
1
Notice!
Option 2 is available only when the warning device (such as horn speaker) is connected to
any of the output 1 – 3.
System Options 2
Item
Location
Option
Default New
System Options 2
0493
1 = Codepad panic to be silent
2 = Codepad fire to be silent
4 = Codepad medical to be silent
8 = Access denied (code retries) to be silent
0
4.14.12
4.14.13
4.14.14
4.15
4.15.1
4.15.2
Control Panel
Programming Parameters | en
41
Bosch Security Systems, Inc.
Quick Reference Guide
2015.06 | 03 | F.01U.298.027