14 Technical data
Technical data vary according to the version of the VT-HNC100...3X. A detailed
description of you axis control is available in the data sheet RE 30139.
In addition, you can here find data on the two bus systems PROFINET RT
and EtherNet/IP:
Bus system
PROFINET RT
EtherNet/IP
Functionality
PROFINET IO RT Device
EtherNet/IP adapter
Conformance Class A
Remote Reset: 0/1
Protocols (CM, RTC, RTA, ARP, ICMP,
LLDP)
Connection Classes 1/3(Exclusive Owner,
Listen Only)
Alarm support
Unconnected Explixit Messaging
Max. 1 API supported
DHCP support
Minimum cycle time
2 ms
Max. size of the cyclic I/O data
992 byte (max. 496 496 byte per direction)
Transmission rate
100 Mbit/s, full-duplex
Interface
Integrated cut-through switch
– 3-port switch (2 x external, 1 x internal)
– Pass-through delay min. 0.9 us / max. 1.4 us
Specification
Conformity with the relevant IE standard
Diagnosis LED
2 x port status LEDs (Link, Activity)
1 x module status (red / green)
1 x network status (red / green)
Recommendations for bus operation
– Separation of the IE network from standard Ethernet network (company network)
– Alternative connection to the superior standard Ethernet company network via router
(e.g. level-3 router)
– Separation of standard Ethernet devices (e.g. PCs) in other partial areas (segments) with
additional integration into the IE network