38/
48
Bosch Rexroth AG
VT-HNC100...3X | RE 30139-B/12.14
Commissioning
Further information on operation, project planning, programming and diagnosis
of the control system with WIN-PED® 6 is available in the help menus of the
program.
7.2 Commissioning software wIN-PED
®
6 and
wIN-PED
®
7
For commissioning and for later operation, the user can apply the PC program
WIN-PED®. It can be used for the programming, setting and diagnosis of the
VT-HNC100...3X. Functionality, menus and program windows are adjusted to the
variants of VT-HNC100...3X.
Projects established with WIN-PED® 6 are not compatible with projects from
WIN-PED® 7. Automatic conversion is not possible. However, it is possible to edit
the projects manually.
Ethernet-capable hardware requires WIN-PED® 7. Any other hardware version
operates both with WIN-PED® 6 and WIN-PED® 7.
WIN-PED® offers the following functions:
•
Convenient dialog functions for the online or offline settings of the machine data
•
NC editor with integrated syntax check and program compiler
•
Support for the definition of the parameters used in the NC program
•
Dialog window for the online setting of the parameter values
•
Various options for the display of the process parameters for digital inputs,
outputs and flags
•
Recording and graphic illustrations of up to 16 process parameters with a great
choice of trigger options
•
Dialog for the graphic definition of special functions (determination of the
function through a traverse)
•
Bus manager for the configuration of data exchange (PROFIBUS DP,
PROFINET RT or CANopen) with superior control
The PC program “WIN-PED” is not included in the scope of delivery of the
VT-HNC100...3X. Download on the Internet:
www.boschrexroth.com/hnc100
7.3 Installation requirements
The following system specifications are required for the PC program WIN-PED®:
•
IBM PC or compatible system
•
Windows XP or Windows 7 for WIN-PED® 6
•
Windows XP or Windows 7 for WIN-PED® 7
•
Main memory (recommendation: 512 MB)
•
100 MB available hard drive capacity for each control type
•
RS 232 interface for VT-HNC100...3X connection; for the PROFINET RT,
EtherNet/IP or PROFIBUS DP, also the network interface TCP/IP can be used
•
An interface cable RS232 (length 3 m; Material no.
R900776897)
as well
as an USB RS232 converter (Material no.
R901066684
)
are
not
included in
the scope of delivery, can, however, be ordered separately. See chapter 6.2
“Recommended accessories” on page 21.