CAN-Bus peripheral equipment
IOKind Block 3
:
1
1stAdr Block 3
:
16
Length Block 3
:
8
Ident.Block 3
:
393
Bus-no.Block 3
:
2
Address areas of the CAN outputs (P32)
The image of the analog CAN outputs is deposited in the rho4 in a sepa-
rate RAM area. Machine parameter P32 configurates the CAN outputs.
For each analog output block, the following subparameters are to be as-
signed:
D
I/O-type:
Analog modules get the code 1, digital modules the code 0.
D
Start address:
This relative address indicates the position of the data block (8 bytes)
within the rho4 internal RAM area. For inputs and outputs there are 2
RAM areas physically separated.
The setting is to be performed as follows:
1stAdr Block 1
:
0
1stAdr.Block 2
:
8
1stAdr Block 3
:
16
1stAdr Block 4
:
24
1stAdr Block n
:
(n−1) * 8
In this RAM area, only analog input blocks are taken into account. For
digital output blocks, the start address relates to the rho interface.
D
Block length:
The block length has for all analog modules that are available at the
moment 8 bytes (4 channels).
D
Identifier:
A bus switching can supply a maximum of input blocks (32-I-byte) and
4 output blocks (32-O-Byte).
The CAN identifier for the corresponding input block results from the
node-ID set by means of the hardware of the B~IO M-CAN-module:
output block
output byte
CAN-Identifier
1
1 to 8
512 + Node-ID
2
9 to 16
768 + Node-ID
3
17 to 24
512 + Node-ID + 1
4
25 to 32
768 + Node-ID + 1
Содержание Rexroth Rho 4.0
Страница 12: ...XII Electric Drives and Controls Bosch Rexroth AG RhoMotion 1070072367 04 Contents Notes ...
Страница 22: ...2 2 Electric Drives and Controls Bosch Rexroth AG RhoMotion 1070072367 04 System overview Notes ...
Страница 78: ...4 14 Electric Drives and Controls Bosch Rexroth AG RhoMotion 1070072367 04 PCLrho4 0 Notes ...
Страница 168: ...A 4 Electric Drives and Controls Bosch Rexroth AG RhoMotion 1070072367 04 Appendix Notes ...