The shield length (X) is 10 mm, the wire length (Y) is 40 mm.
2. Put the wires of the motor cable into the motor connector according to the
instructions of the connector manufacturer. Keep the wires of the motor
cable to the connector as short as possible (!).
Securely attach the motor cable (E) to the shield and support bracket (F).
F
C
D
E
!
Fig. 10-13: Connecting the wires of the motor cable
Use the tie-wrap with the EMC gasket (C) to clamp the shield of the cable
against the metal bracket.
Use the standard tie-wrap (D) to attach the cable firmly onto the metal
bracket.
3. Put the hook of the shield and support bracket (F) into the slit at the left
side of the header on the metal base of the system housing. Lock the
shield and support bracket (F) onto the base plate with the screw (G).