12/14
Bosch Rexroth AG, MIT: LU 2/LS, 3 842 562 440/2020-09
Fig. 4:
562 440-04
13
12
1...
2
10
9
GN
GN
11
Installing the drive with LC 2/LS grease cartridge in support bracket
Please note:
After re-establishing the supply voltage a delivery process is carried out. During
the delivery the drive and the LED indicators fl ash at 1s intervals.
Please note:
• The delivery volume is
pre-set to 0.5 cm³ per
impulse at the factory.
• The grease cartridge may
only be screwd-in 1 x.
• During the following
work, grease may
leak from the grease
cartridge.
9.
Label the grease
cartridge with the
assembly and the
replacement date.
10.
Remove the plug of the
grease cartridge.
11.
Screw the lubrication
unit by hand into the
supporting bracket (D).
12.
Remove the protective
cap.
13.
Connect the connection
cable to the lubrication
unit.
The lubricating unit
is ready for operation
with the factory set
parameters.