9.9
Mouse Interface XMouse
Type
PS/2 Mini DIN female connector, 6-pin
If a PS/2 mouse is not recognized by the system, the mouse has to be activated in the
BIOS by switching from "Disabled" to "Autodetect". Connecting the external mouse af‐
terwards, is not detected by the operating system. Initialization is carried out during the
boot process only.
The connected mouse must comply with the PS/2 standard. Generally, the
BIOS reserves IRQ 12 for the PS/2 mouse. If there are address conflicts,
e. g., if IRQ 12 is already used by different extension cards of the PC,
change the IRQ of this extension card to another, still unassigned IRQ.
9.10
Audio Interface XAudio
At the XAudio connections also Audio inputs and outputs are available. The Audio in‐
terfaces are disabled in the BIOS ex works.
9.11
UPS with USB Interface
When connecting a UPS to a USB interface at the control cabinet PC, the information
regarding the existence and the status of the UPS are communicated to the control
cabinet PC.
Fig.9-2: UPS with communication (via USB) to the control cabinet PC
The communication is established via a virtual COM interface. This virtual COM inter‐
face is provided by the USB interface.
The USB connection XUSB2 has already been configured for the UPS connection
fig. 9-1 "View on the connector panel" on page 18
.
The driver is installed after the first connection of the UPS via the USB ca‐
ble. A virtual COMn (e.g. COM3) interface is created in the operating sys‐
tem.