VDP 16.1, VDP 40.1 and VDP 60.1
Technical Data
4-3
DOK-SUPPL*-VDP16/40/60-PR02-EN-P
The devices of the VDP family are basically certificated according to
•
UL508
(Industrial Control Equipment) and
•
C22.2 No. 14-M95
(CSA)
However, it is possible that there are combinations or extension stages
with restricted or missing certification. Thus, verify the registration
according to the UL marking on the device.
Note:
To guarantee an UL/CSA-compliant operation, you have to
fulfill the following conditions:
•
Use
60/75
°
C copper wire only.
•
Use Class 1 wire only or equivalent.
4.5 Wear
Parts
The service life of the
backlight
is limited to a certain number of
operating hours. After this time the backlight will produce only 50 % of
its original brightness. This time differs for the used displays:
Display seize
Service life
12"
40,000 hours
15"
35,000 hours
Fig. 4-6: Service life of the backlight
•
Also
fans
are mechanic wear components, whose service life is
extremely temperature-dependent. For the fan the manufacturer
specifies the following service life:
Ambient temperature
(surrounding air temperature)
Service life
20 °C
45,000 hours
60 °C
15,000 hours
Fig. 4-7: Service life of the fan
4.6 Compatibility
Test
All Rexroth controls and drives are developed and tested according to the
latest state-of-the-art.
As it is impossible to follow the continuing development of all materials
(e.g. lubricants in machine tools) which may interact with our controls and
drives, it cannot be completely ruled out that any reactions with the
materials used by Bosch Rexroth might occur.
For that reason, test new lubricants, cleaning agents, etc. for compatibility
with our housings / our housing materials before using the particular
material concerned.
UL/CSA Certification
Wear parts without warranty
Содержание Rexroth IndraControl VDP 16.1
Страница 6: ...IV Contents VDP 16 1 VDP 40 1 and VDP 60 1 DOK SUPPL VDP16 40 60 PR02 EN P ...
Страница 14: ...1 8 System Presentation VDP 16 1 VDP 40 1 and VDP 60 1 DOK SUPPL VDP16 40 60 PR02 EN P ...
Страница 30: ...4 4 Technical Data VDP 16 1 VDP 40 1 and VDP 60 1 DOK SUPPL VDP16 40 60 PR02 EN P ...
Страница 44: ...5 14 Dimensions VDP 16 1 VDP 40 1 and VDP 60 1 DOK SUPPL VDP16 40 60 PR02 EN P ...
Страница 58: ...6 14 Display and Operating Components VDP 16 1 VDP 40 1 and VDP 60 1 DOK SUPPL VDP16 40 60 PR02 EN P ...
Страница 68: ...7 10 Interfaces VDP 16 1 VDP 40 1 and VDP 60 1 DOK SUPPL VDP16 40 60 PR02 EN P ...
Страница 72: ...9 2 Touch Screen Software VDP 16 1 VDP 40 1 and VDP 60 1 DOK SUPPL VDP16 40 60 PR02 EN P ...
Страница 82: ...12 4 Index VDP 16 1 VDP 40 1 and VDP 60 1 DOK SUPPL VDP16 40 60 PR02 EN P ...
Страница 89: ......