System stop "Misconfiguration"
The following I/O configurations lead to a system stop caused by a misconfi‐
guration:
●
No I/O modules equipped.
●
More than 16 I/O modules equipped.
●
More than 64 bytes inputs equipped.
●
More than 64 bytes outputs equipped.
●
The total of the parameterization data of all modules is greater than
64 bytes.
●
The total of the parameterization data of all modules is greater than
64 bytes.
System stop "Exceptional error
Hardware (HW)"
When booting the bus connection ("Network on"), the hardware components
are tested. Furthermore, during the cyclic operation the I/O configuration and
the transmission quality to the I/O modules are monitored. If an error occurs,
the assembly is set to system stop "Exceptional error HW".
8.7
Address Assignment
8.7.1
Keypads
General Information
Each Sx.y key (input) is assigned to a green LED Hx.y (output). The keypads
are connected to the logic circuit board via the internal shift register bus. The
inputs (buttons) and outputs (LEDs) of the keypad are mapped in the "Key‐
pad TA" module on the fieldbus. For each of the keypads, 1 and 2, in the
PROFIBUS configurator a module "Keypad TA" has to be configured.
Fig.8-5:
Keypad TA
DOK-SUPPL*-VAM*XX.1***-PR02-EN-P
Rexroth IndraControl VAM 12.1/42.1 Machine Control Panels
Bosch Rexroth AG
75/93
Maintenance and Commissioning
Содержание REXROTH IndraControl VAM 12.1
Страница 28: ...Bosch Rexroth AG DOK SUPPL VAM XX 1 PR02 EN P Rexroth IndraControl VAM 12 1 42 1 Machine Control Panels 26 93 ...
Страница 36: ...Bosch Rexroth AG DOK SUPPL VAM XX 1 PR02 EN P Rexroth IndraControl VAM 12 1 42 1 Machine Control Panels 34 93 ...
Страница 72: ...Bosch Rexroth AG DOK SUPPL VAM XX 1 PR02 EN P Rexroth IndraControl VAM 12 1 42 1 Machine Control Panels 70 93 ...
Страница 90: ...Bosch Rexroth AG DOK SUPPL VAM XX 1 PR02 EN P Rexroth IndraControl VAM 12 1 42 1 Machine Control Panels 88 93 ...
Страница 92: ...Bosch Rexroth AG DOK SUPPL VAM XX 1 PR02 EN P Rexroth IndraControl VAM 12 1 42 1 Machine Control Panels 90 93 ...