Profibus DP 61/176
3 842 530 344/2014-05, MIT: ID 40,
Bosch Rexroth AG
SLK operation
Check the actual link state until the value
CONNECTED
appears (2). A new MDT has
now arrived. The controller reads the MDT status (4). When the MDT status does not
indicate an error, the user data can now be read starting with MDT address 0x0110.
Once this data has been evaluated and the workpiece processed, the result of
the processing is written to the MDT (6). Communication with the MDT is then
terminated.
No.
Command-oriented data
exchange
CMD
Data0 Data1 Data2 Data3 Data4 Data5 Data6
2
Wait until actual link state is
CONNECTED
. Read value through event-oriented data channel
4
Read MDT status and
check if error bits are
present
0x05
0x00
0x02
0x00
0x00
0x00
0x01
5
Read data from MDT,
e.g., 32 bytes as of ad-
dress 0x0110
0x05
0x00
0x00
0x01
0x10
0x00
0x20
6
Write data to MDT, e.g.,
60 bytes as of address
0x0100
0x06
0x00
0x00
0x01
0x00
0x00
0x3C
data...
8
Close MDT
(RECONNECT)
0x06
0x00
0x03
0x00
0x01
0x00
0x01
0x03
9
Wait until actual link state is
CONNECTING
. Read value through event-oriented data channel
PROOF COPy 1 | 20.05.2014 | FOR INTERNAL USE ONLy
EN