![Bosch Rexroth Hagglunds DOb Скачать руководство пользователя страница 48](http://html.mh-extra.com/html/bosch/rexroth-hagglunds-dob/rexroth-hagglunds-dob_installation-and-maintenance-manual_40577048.webp)
48/80
VFD (Variable frequency drive)
Bosch Rexroth AB,
Installation and maintenance manual, Hägglunds DOb, RE 15327-WA/05.2017
9.3 Functions and Parameters
9.3.1 Functions and Parameters used in VFD for main pump electric motor
Parameter Value
Name
Comment
C0:Power control parameters
C0.01
0
Duty cycle
Normal duty
C1:Motor and system parameters
C1.05
7,5
Motor rated power
C1.06
400
Motor rated voltage
C1.07
15
Motor rated current
C1.08
50
Motor rated frequency
C1.09
1460
Motor rated speed
C1.10
0,82
Motor rated power factor
C1.69
0
Motor thermal protection
setting
Inactive. Since PTC in use
C1.75
20
Low speed derating
frequency
f=n/30
n=speed (rpm), f=frequency (Hz)
n=600 rpm
C2: V/F control parameters
C2.07
100
Slip compensation factor 1-100% full slip compensation
E0: Set point and control parameters
E0.00
0
First frequency setting
source
0- Potentiometer
E0.02
3
Second frequency setting
source
3-AI 2 analog input
E0.08
120
Maximum output
frequency
Allowed maximum output frequency. f=n/30
n=3600 rpm (Max. speed of pump)
E0.09
100
Output frequency high
limit
According to application.
f=n/30
n=3000 rpm
E0.10
5
Output frequency low
limit
According to application.
f=n/30
n=150 rpm
E0.15
1
Low speed running mode
1- running with low frequency limit when
output frequency lower than Output
frequency low limit (E0.10)
E0.17
1
Direction control
1: Forward only
E0.26
6
Acceleration time
Ramp rise time
E0.27
6
Deceleration time
Ramp fall time