Technical data 75/84
3 842 564 989/2022-06, MIT: HQ 2/G-H, BS 2/G-250,
Bosch Rexroth AG
16 Technical data
• For dimensions, see sales catalog TS 2
plus
• Maximum section load: 2.0 kg/cm support surface length
• Maximum load: 250 kg
• Noise emissions: < 70 dB (A)
16.1 Ambient conditions
• The transfer systems have been designed for stationary use in a location that is
protected from the elements.
• Operating tempe5 °C to +40 °C
–5 °C to +60 °C at 20 % reduced load
• Storage temperature
–25 °C to +70 °C
• Relative humidity
5 % to 85 %, non-condensing
• Air pressure
> 84 kPa, corresponds to an installation altitude
< 1400 m above sea level
• Max. load capacity of floor: 1000 kg/m
2
• At installation altitudes > 1400 m, the load values of the electric drives are
reduced by 15%.
• The area should be kept free of mold, fungus, rodents and other vermin.
• Do not install or operate in the immediate vicinity of industrial equipment
producing chemical emissions.
• Do not install or operate near sources of sand or dust.
• Do not install or operate in areas that are regularly subjected to high-energy
forces caused, for example, by presses or heavy machinery.
• Resistant to many media that are commonly found in manufacturing, such as
water, mineral oil, grease, and detergents. Contact your Rexroth representative
if you have any doubts about resistance to specific chemicals, such as test oil,
doped oils, corrosive detergents, solvents or brake fluid.
• Avoid prolonged contact with highly reactive acidic or alkaline materials.
16.2 Pneumatics
• Oiled or non-oiled, filtered, dry compressed air.
• Operating pressure
4 to 6 bar
• Solids
– Particle size
– Particle quantity
≤ 5 µm
≤ 5 mg/m
3
(Class 6 as per ISO 8573-1:2010)
(Class 6 as per ISO 8573-1:2010)
• Humidity – water content
– Pressure dew point
1
)
≤ +3 °C
(Class 4 as per ISO 8573-1:2010)
1
) The pressure dew point should be at least 15 °C below the ambient temperature.
• Oil content
– Oil quantity
≤ 1 mg/m
3
(Class 3 as per ISO 8573-1:2010)
EN