RE 92110-01-B/2022-03-22, Bosch Rexroth AG
Assembly |
A4VSH series 1x and 30 37
/64
1
1
1
2
3
2
1
Fig� 11: Removing transport protection
1
Protective covers
2
Protective plugs/threaded plugs
3
Protective cover for through drive
Ports intended for connecting lines come with protective plugs and/or threaded
plugs, which serve as transport protection. Make sure all ports required for
functional operation are connected (see Table 11 "Ports A4VSH series 1x and 30"
on page 40). Failure to do so could lead to malfunctions or damage. If a port
is not being used, plug it with a threaded plug since the protective plugs are not
pressure-resistant.
Adjusting the setting screws will render the warranty void. If you need to
change the settings, please contact your local contact person; you can find their
contact information at
https://addresses.boschrexroth.com
3�
For versions with through drive, install the auxiliary pump according to the
pump manufacturer's manual. The protective cover (
3
) is not pressure-resistant
and should not be used during operation. O-ring and mounting bolts are