Fig� 8: Inside-reservoir installation A4VSH with installation position 7–8
K
2
, K
3
Drain port
T
,
R(L)
Filling/air bleeding
F
Filling/air bleeding
U
Bearing flushing
S
A
Anti-cavitation valve port
S
B
Anti-cavitation valve port
h
t min
Minimum required immersion depth
(200 mm)
h
min
Minimum required distance to
reservoir bottom (100 mm)
SB
Baffle (baffle plate)
Table 9: Inside-reservoir installation
Installation position
Air bleed
Filling
7 (drive shaft horizontal)
R(L)
R(L)
8 (drive shaft vertically up)
Bearing flushing at port
U
required (see data
sheet 92110)
T
,
U
T
,
U
7�3�3 Above-reservoir installation
Above-reservoir installation means that the axial piston unit is installed above the
minimum fluid level of the reservoir.
Above-reservoir installation is only possible at size 40 to 125 and should be avoided
at size 250.
Ensure that the axial piston pump with above-reservoir installation has
a minimum suction pressure of 1 bar at port
S
A
and
S
B
of the anti-cavitation
valve during operation in all installation positions during operation and during
cold start. The maximum pressure of 16 bar at port
S
A
and
S
B
must not be
exceeded.
For installation position (drive shaft upward): A check valve in the drain line
should be avoided and is only permissible on a case-by-case basis upon request.
Please consult your proper contact person at Bosch Rexroth.