①
Cover
②
Seal
③
Terminal block U-V-W
④
PE connection
⑤
O-ring
⑥
Adapter plate mounting screws
⑦
Safety cover of the connection thread of the cable gland
⑧
Adapter plate for cable gland
⑨
Terminal strip (brake, temperature sensor)
⑩
Purging gas connection (only applicable to Ex-type motors)
⑪
Clamping screws for setting the outgoing cable direction (4 pcs.)
Fig.6-8:
Terminal box
2.
Turn out the safety cover of the cable gland ⑦.
3.
Detach the adapter plate ⑧ from the terminal box.
4.
Firmly secure the adapter plate to the metric cable gland on the power
cable.
①
O-ring position
Fig.6-9:
O-ring at cable gland
⇒ Before attaching the adapter plate to the power cable, visually check
the O-ring on the cable gland of the power cable to verify its proper state
and correct position. If the O-ring is missing, do not use the power ca‐
ble. In this case, please contact your local Rexroth sales or service part‐
ner.
5.
Run the power cable to the adapter plate through the opening into the
terminal box and reattach the adapter plate to the terminal box.
Bosch Rexroth AG
DOK-MOTOR*-2AD********-IT01-EN-P
Rexroth 2AD Asynchronous Housing Motors
38/61