①
Ring screw (check firm seating before use)
Fig.5-1:
Lifting and transport of motors
Before transporting the motor, determine the weight of the motor. For
details about motor weight refer to type plate or project planning manual
Rexroth 2AD.
Adjust the carrying capacity of the lifting device to the motor weight.
Avoid increased transport vibrations.
Remove any existing transport locks prior to commissioning and keep them
5.3
Product Storage
Store the motors in their original package at a dry, dust free, vibration free
and light protected place without direct solar radiation. Please observe
classes 1K2, 1B1, 1C1,1S1,1M2 specified for storage acc. to DIN EN
60721-3-2.
Please observe the following classification limitations:
●
Storage temperature -20 ... +60 ℃
●
Relative air humidity 5 … 95 %
●
Absolute air humidity 1 … 29 g/m³
●
No condensation
●
No ice formation/freezing
●
No occurrence of salt mist
Damage due to moisture and humidity!
NOTICE
Use coverings to protect the products from moisture.
Store them only in rainproof and dry rooms.
Before storage, discharge the liquid coolant from liquid-
cooled motors to avoid frost damage.