Installation 41/60
RE 92801-01-B/11.2018, A15VSO/A15VLO Series 11,
Bosch Rexroth AG
7.4.9 Electrically connecting the axial piston unit
NOTICE
Short circuit due to penetrating hydraulic fluid!
Fluid can penetrate the product and cause a short circuit!
▶
Do not install axial piston units with electric components (e.g. electric controls,
sensors) in a reservoir below the fluid level (inside-reservoir installation).
Exception: Installation of the axial piston unit with E2 /E6 control. However only
with Hirschmann connector and if mineral hydraulic fluids are used and the fluid
temperature in the reservoir does not exceed 80 °C.
The machine/system manufacturer is responsible for electric control layout.
Electrically controlled axial piston units must be connected in accordance with the
electrical circuit diagram for the machine/system.
For axial piston units with electrical control and/or mounted sensors, observe the
information in data sheet 92801, e.g.:
• Permissible voltage range
• Permissible current
• Correct pin assignment
• Recommended electrical control units
Exact details on the connector, type of protection and matching mating connector
can also be found in data sheet 92801. The mating connector is not included in the
scope of delivery.
1.
Switch off the power supply to the relevant system component.
2.
Electrically connect the axial piston unit (12 or 24 V). Before establishing the
connection, check whether the connector protective covers have been removed
and the connector and all seals are intact.