8.4 Fan
control
The PRS-1P500, PRS-2P250 and PRS-4P125 amplifiers,
from HW version 06/00 onwards, have a fan
monitoring circuit that detects the actual fan rotation.
This detection is needed for compliancy to the standards
UL864 and UL1711, for use in the USA. Additionally
the internal fans need to run at full speed for
compliancy to these standards. A jumper on the main
PCB selects between two positions:
•
Normal (factory default) - The fans are temperature
controlled, normally running at low speed and
switching to high speed in case the temperature
exceeds a certain level. Fan monitoring is not
activated.
•
Full speed - The fans run at full speed continuously.
Fan monitoring is activated. Do not enable Switch
amplifiers to standby (see section 44.4) for this
selection, because in standby the fans are stopped
and a fault would be generated.
The jumper is indicated on the PCB as X18; connection
1-2 selects Normal, connection 2-3 selects Full speed.
See figure 8.15.
figure 8.15: Jumper X18 provides fan control for PRS-1P500, PRS-2P250 and PRS-4P125
PRS-1P500, PRS-2P250 and PRS-4P125
1
2
3
X18
Содержание Praesideo 3.5
Страница 1: ...Praesideo 3 5 Installation and User Instructions Digital Public Address and Emergency Sound System en ...
Страница 131: ...Bosch Security Systems 2011 02 Praesideo 3 5 Installation and User Instructions 4 Amplifiers en 131 Part 4 Amplifiers ...
Страница 201: ...Bosch Security Systems 2011 02 2011 02 Installation and User Instructions 5 Call Stations en 201 Part 5 Call Stations ...
Страница 309: ...Bosch Security Systems 2011 02 Praesideo 3 5 Installation and User Instructions 8 Software en 309 Part 8 Software ...
Страница 411: ...Bosch Security Systems 2011 02 Praesideo 3 5 Installation and User Instructions 10 Events en 411 Part 10 Events ...
Страница 487: ...Bosch Security Systems 2011 02 Praesideo 3 5 Installation and User Instructions 12 Appendices en 487 Part 12 Appendices ...
Страница 497: ......
Страница 498: ... Bosch Security Systems B V Data subject to change without notice 2011 02 ...