54
en | Appendices
PAVIRO Call Stations
2018.04 | 04 | F01U306899
Bosch Security Systems
5.
Set a unique address for the call station extension via the
DIP switch EXTENSION ADDRESS (see table below).
Notice!
When using several call station extensions, these must be
assigned addresses in ascending order from left to right (1–5).
6.
Re-connect the call station connections
7.
Configure the call station extension using the IRIS-Net
software
Notice!
If a call station extension is replaced in a call station system
that has already been configured, the replacement device must
be assigned the address of the replaced device via the DIP
switch EXTENSION ADDRESS.
DIP Switch
ID
Comment
4
3
2
1
-
OFF
OFF
OFF
0
Disconnected
-
OFF
OFF
ON
1
-
OFF
ON
OFF
2
-
OFF
ON
ON
3
-
ON
OFF
OFF
4
-
ON
OFF
ON
5
Tab.
11.1:
Extension address