F 002 DG9 A14
2016-07-07
|
Bosch Limited
Decommissioning | NTI 105 | 15
en
9.
Decommissioning
R
Disconnect the NTI 105 from the mains.
R
Shut off and disconnect the pneumatic supply.
R
Cover the NTI 105.
9.1
Change of location
R
If the NTI 105 is passed on, all the documentation
included in the scope of delivery must be handed over
together with the unit.
R
The NTI 105 has to be transported in the original or
equivalent packaging.
R
Heed the notes on initial commissioning.
R
Contact Bosch customer service to shift the NTI 105
from one place to another.
R
During transportation, fit transportation safeguards.
R
Ensure that there are no loose parts.
9.2
Disposal and scrapping
9.2.1
Substances hazardous to water
!
Oils and greases as well as refuse containing oil and
grease (e.g. filters) represent a hazard to water.
R
Substances hazardous to water must not be allowed
to enter the sewage system.
R
Substances hazardous to water must be disposed of
in accordance with the applicable regulations.
9.2.2
NTI 105 and accessories
R
Disconnect the NTI 105 from the mains and detach
the power cord.
R
Dismantle the NTI 105. Sort out and dispose of the
different materials in accordance with the applicable
regulations.
Dispose of used electrical and electronic devices,
including cables, accessories and batteries, separately
from household waste.
¶
Make use of the local return and collection systems
for disposal.
¶
Proper disposal of the NTI 105 prevents environmen-
tal pollution and possible health hazards.
8.
Technical data
Parameter
Value
Overall dimensions
Length
454 mm
Height
1140 mm
Width
594 mm
Weight
85 kg
Input
Air Input at FRC
300 lpm at 10 bar
Pressure
8 to 16 bar
Electrical specifications
Electrical power
25 W
Voltage
230 V ± 10% VAC
Frequency
50 ± 1% Hz
Phase
Single
Connection
L – N – PE
Output
Internal Nitrogen tank capacity
60 l
Nitrogen purity
≥
96%
Nitrogen output
60
lpm
Gas selection
Nitrogen / Air
Regulation
Digital / Direct
Pressure gauges
Inlet pressure gauge
0 to 16 bar
Tank pressure gauge
0 to 16 bar
Permissible ambient temperature ranges
Maximum ambient temperature
45 °C
Operating range
5 to 45 °C
Storage temperature
0 to 60 °C
Miscellaneous
Length of filling hose
8 m
Protection
IP54