F 002 DG9 A14
2016-07-07
|
Bosch Limited
Program description | NTI 105 | 13
en
6.
Program description
6.1
Overview of operation
The following functions are available in the software:
R
Initiate nitrogen generation
R
Tire inflation and deflation
R
Tire inflation counter
R
Software update
6.2
Main menu
Menu option
Function
INFLT
Start tire inflation
DEFLT
Start tire deflation
SETUP
R
Initiate calibration of pres-
sure sensor to atmospheric
pressure
R
Set filling accuracy
COUNT
View number of tires filled
i
The
COUNT
option displays the number of tires filled
only if the initial pressure difference during inflation
is greater than 10 psi.
6.3
Initiating nitrogen generation
After the NTI 105 is powered on, nitrogen generation
starts automatically.
i
If the NTI 105 is idle, the CMS valves can be
switched off manually. In turn the load on the
compressor reduces resulting in energy savings.
However, ensure that you switch on the CMS valves
after you switch on the NTI 105. Else, the quantity
of nitrogen left in the tank will be filled and the set
pressure may not be achieved.
i
The purity of nitrogen increases after each cycle of
filling.
¶
To manually stop the nitrogen generation, press the
z
key
.
"
The message
CMS VALVES SWITCHED OFF
is dis-
played on the LCD.
¶
To start the nitrogen generation again, press the
v
key.
"
The message
CMS VALVES SWITCHED ON
is displayed
on the LCD.
i
To switch on the CMS valves, press
1
(Inflate) or the
v
key. To switch off, press the
z
key.
6.4
Tire inflation
i
Observe the tank pressure. It should be 8 bar. If
the pressure is lower, wait till the pressure reaches
8 bar.
i
Usually the filling pressure is mentioned in the sill
of the driver's door. Open the drivers's door of the
vehicle and observe the filling pressure. Else, refer to
the vehicle documentation.
1.
Select nitrogen or air inflation using the toggle
switch.
2.
In the main menu, press
1
.
i
To change the unit between
Bar or PSI,
press the
UNIT
key.
3.
Select the filling accuracy (refer chapter 4.4).
4.
Connect the filling nozzle to the tire.
5.
Press
Enter
.
Hold the filling nozzle to the tire until the set pres-
sure is reached. After the set pressure is reached,
a long beep is heard and the green LED glows.
6.
Remove the filling nozzle and connect it to the next
tire.
"
The tire inflation resumes automatically within 15
seconds without pressing the
ENTER
key. To stop tire
inflation, press
Abort
.
6.5
Tire deflation
1.
In the main menu, press
2
.
2.
Hold the filling nozzle till the tire gets deflated.
After the set pressure is reached, a long beep is
heard and the status indication LED glows. The
message
TIRE DEFLATION COMPLETED
is dis-
played on the LCD. The main menu is displayed.
3.
Repeat steps 1 and 2 for all the tires. To stop tire
deflation, press
Abort
.
6.6
Tire inflation counter
¶
In the main menu, press
4
.
"
The number of tires filled is displayed. After about 10
seconds the message is dismissed automatically and
the main menu is displayed. A maximum count of 9999
tires is registered by the inflation counter,
6.7
Software update
Contact customer service for enquiries about software
updates.