background image

F 002 DG9 A14

2016-07-07

Bosch Limited

Program description  |  NTI 105  |  13

en

6. 

Program description

6.1 

Overview of operation

The following functions are available in the software:

 

R

Initiate nitrogen generation

 

R

Tire inflation and deflation

 

R

Tire inflation counter

 

R

Software update

6.2 

Main menu

Menu option

Function

INFLT

Start tire inflation

DEFLT

Start tire deflation

SETUP

 

R

Initiate calibration of pres-

sure sensor to atmospheric 

pressure

 

R

Set filling accuracy 

COUNT

View number of tires filled

 

i

The 

COUNT

 option displays the number of tires filled 

only if the initial pressure difference during inflation 
is greater than 10 psi. 

6.3 

Initiating nitrogen generation

After the NTI 105 is powered on, nitrogen generation 
starts automatically.

 

i

If the NTI 105 is idle, the CMS valves can be 
switched off manually. In turn the load on the 
compressor reduces resulting in energy savings. 
However, ensure that you switch on the CMS valves 
after you switch on the NTI 105. Else, the quantity 
of nitrogen left in the tank will be filled and the set 
pressure may not be achieved. 

 

i

 The purity of nitrogen increases after each cycle of 
filling.    

 

To manually stop the nitrogen generation, press the 

key

.

 

"

The message 

CMS VALVES SWITCHED OFF

 is dis-

played on the LCD.

 

To start the nitrogen generation again, press the 

v

 

key.

 

"

The message 

CMS VALVES SWITCHED ON

 is displayed 

on the LCD.

 

i

To switch on the CMS valves, press 

1

 (Inflate) or the 

key. To switch off, press the 

z

 key. 

6.4 

Tire inflation

 

i

Observe the tank pressure. It should be 8 bar. If 
the pressure is lower, wait till the pressure reaches 
8 bar.

 

i

Usually the filling pressure is mentioned in the sill 
of the driver's door. Open the drivers's door of the 
vehicle and observe the filling pressure. Else, refer to 
the vehicle documentation.

1. 

Select nitrogen or air inflation using the toggle 
switch.

2. 

In the main menu, press 

1

.

 

i

To change the unit between 

Bar or PSI, 

press the 

UNIT

 key.

3. 

Select the filling accuracy (refer chapter 4.4).

4. 

Connect the filling nozzle to the tire.

5. 

Press 

Enter

.

 

Hold the filling nozzle to the tire until the set pres-
sure is reached. After the set pressure is reached, 
a long beep is heard and the green LED glows.

6. 

Remove the filling nozzle and connect it to the next 
tire. 

 

"

The tire inflation resumes automatically within 15 
seconds without pressing the 

ENTER

 key. To stop tire 

inflation, press 

Abort

.

6.5 

Tire deflation

1. 

In the main menu, press 

2

.

2. 

Hold the filling nozzle till the tire gets deflated.

 

After the set pressure is reached, a long beep is 
heard and the status indication LED glows. The 
message 

TIRE DEFLATION COMPLETED

 is dis-

played on the LCD. The main menu is displayed.

3. 

Repeat steps 1 and 2 for all the tires. To stop tire 
deflation, press 

Abort

.

6.6 

Tire inflation counter

 

In the main menu, press 

4

.

 

"

The number of tires filled is displayed. After about 10 
seconds the message is dismissed automatically and 
the main menu is displayed. A maximum count of 9999 
tires is registered by the inflation counter,

6.7 

Software update

Contact customer service for enquiries about software 
updates.

Содержание NTI 105

Страница 1: ... NTI 105 en Original instructions Nitrogen tire inflator ...

Страница 2: ......

Страница 3: ...ssioning 8 4 1 Removing the transport packaging 8 4 1 1 Opening the NTI 105 8 4 2 Installation 8 4 3 Gas selection 10 4 3 1 Digital outlet 10 4 3 2 Direct outlet 10 4 4 Accuracy setting 10 5 Troubleshooting 11 5 1 Based on error codes 11 5 2 Based on symptoms 11 6 Program description 13 6 1 Overview of operation 13 6 2 Main menu 13 6 3 Initiating nitrogen generation 13 6 4 Tire inflation 13 6 5 Ti...

Страница 4: ... by persons with sufficient knowledge and experience in using pressurized devices and also be aware of the risks involved in the use of pressurized devices 2 2 Agreement Your use of the product means that you accept the fol lowing conditions Copyright Software and data are the property of Bosch Limited hereafter denoted as Bosch or its suppliers and are protected against unauthorized reproduction ...

Страница 5: ...over to another person not only the operating instructions but also the safety instructions and information on its designated use must be handed over to the person R R Always switch off the main power supply before per forming any installation or maintenance work R R Do not open the front panel of the NTI 105 or tamper with the pneumatic connections R R Do not try to perform any maintenance activi...

Страница 6: ...ery specification Description NTI 105 PVC pipe at outlet Tire valve connector Male connector Male connector G 1 4 Hose clip NTI 105 original instructions Power cable Tab 1 Delivery specification 3 3 Description of unit 3 3 1 NTI 105 1 2 3 4 5 6 7 8 9 10 12 A14_01 11 Fig 1 Front view 1 Nitrogen tank 2 Display 3 Toggle switch for changing filling gas 4 Master switch 5 Keypad 6 Front panel 7 Front wh...

Страница 7: ...rticulate matter are filtered Based on their molecular characteristics compressed gases have a tendency to adhere to solid surfaces known as adsorbents The process of compressed gases adhering to adsorbents is known as adsorption When the compressed air is passed through a tank with a Carbon Molecular Sieve CMS the molecules of oxy gen are adsorbed by activated carbon which is an ad sorbent The ot...

Страница 8: ...rface of the NTI 105 cabinet with a di lute solution of detergent using a soft cloth i i To ensure optimum performance ensure that the input pressure is 10 bar or above Also ensure that the pneumatic connections are leak proof 3 4 1 CMS and nitrogen tanks Two CMS tanks Fig 4 Pos 1 are used to convert air to nitrogen The separated nitrogen is collected in a storage tank Fig 1 Pos 1 for further dist...

Страница 9: ...hase mains supply 8 Switch on the compressor 1 2 3 4 A14_13 Fig 7 FRC unit 1 Knob 2 Pressure gauge 3 Drain 4 Input from compressor to FRC 9 Observe the pressure gauge Fig 7 Pos 2 of the FRC The pressure should be at least 8 bar 10 Switch on the mains supply 11 Switch on the master switch of the NTI 105 12 Observe the tank pressure gauge Wait until the tank pressure reaches at least 4 bar 13 Press ...

Страница 10: ...the pressure sensor and the value is displayed on the LCD 4 3 2 Direct outlet If the filling hose is connected to the direct outlet Fig 3 Pos 4 the selected gas air or nitrogen by passes the valve block Hence the pressure is not moni tored by the pressure sensor The tire pressure has to be manually checked 4 4 Accuracy setting It is possible to control the filling time by setting the filling accur...

Страница 11: ...nk R R End fittings of the nitrogen tank are loose R R Safety valve is loosely connected R R Burst or leakage in the pneumatic pipe at the output of nitrogen tank R R Leakage at the end fitting of pressure gauge R R Contact customer service to replace the pneumatic pipe of the CMS tank R R Contact customer service to replace non return valve R R Tighten the end fittings of the nitro gen tank R R T...

Страница 12: ...ct customer service to correct the power supply connections to the termi nal block R R Replace fuse at the power socket Purity of generated nitrogen is very low R R Flow regulator setting altered R R Filtering of compressed air is not proper R R Contact customer service R R Open the drain of the FRC unit to re lease the accumulated moisture at least once every day Deflation not possible R R Manifo...

Страница 13: ... v key To switch off press the z key 6 4 Tire inflation i i Observe the tank pressure It should be 8 bar If the pressure is lower wait till the pressure reaches 8 bar i i Usually the filling pressure is mentioned in the sill of the driver s door Open the drivers s door of the vehicle and observe the filling pressure Else refer to the vehicle documentation 1 Select nitrogen or air inflation using t...

Страница 14: ...RC Press the drain Fig 7 Pos 3 of the FRC till the mist is released Close the drain when the mist is cleared i i Drain the FRC at least once every day 7 Maintenance Do not carry out any maintenance work that is not spe cifically recommended in this chapter Non compliance invalidates warranty 7 1 Spare and wearing parts Description Order number Air filling connector F 002 DG1 A51 Braided hose for o...

Страница 15: ...ions 9 2 2 NTI 105 and accessories R R Disconnect the NTI 105 from the mains and detach the power cord R R Dismantle the NTI 105 Sort out and dispose of the different materials in accordance with the applicable regulations Dispose of used electrical and electronic devices including cables accessories and batteries separately from household waste Make use of the local return and collection systems ...

Страница 16: ......

Страница 17: ......

Страница 18: ......

Страница 19: ......

Страница 20: ...Bosch Limited P B No 3000 Hosur Road Bangalore 560 030 INDIA www boschindia com Mailbox service2 in bosch com F 002 DG9 A14 2016 07 07 ...