46
en | Navigating the Menus
MIC Series 500 Camera
F.01U.173.601 | 2.0 | 2010.11
User’s Manual
Bosch Security Systems, Inc.
remove the privacy mask for the complete video picture as it is currently viewed. Manual
control works as in the Preset sub menu, giving 10 secs of movement before returning to the
same page, which means all privacy masks can be set through the menu controls.
5.12
Pot Test Menu
The POT TEST menu enables the user to view the current position, motor readings, and
internal PSU level of the unit.
When Start is selected, a screen indicating current pan and tilt positions and their respective
motor PWM readings appears. At the bottom of the screen, the current internal voltage is
displayed in Volts. To cancel the test, send a left command and then left again to return to the
main menu.
5.13
MIC Information Menu
The MIC Information menu provides access to a number of statistics which are recorded in
the memory of the MIC 500 Series Camera, mainly for engineering purposes. These statistics
can be viewed through the on-screen menu or Cam-set, but cannot be cleared without a
password from the manufacturer.
MAIN MENU
2/2
POT TEST
POT TEST
SONY SET
SPEED
50
CAPTIONS
DIRECTION
LEFT
PAN : TILT
PRIVACY
POS : PWM : POS: PWM
POT TEST
START
__________________________
MIC INFORMATION
3507:159 :700 :400
ENTER PASSWORD
HELP
PSU : 17.7 V
EXIT
Menu Item
Description
SPEED
Sets the speed of the unit for the POT test (range 1-255).
DIRECTION
Sets the direction of the unit for the POT test (options Left, Right, Up, Down).
START
Initiates the Pot Test process. Continual commands are sent requesting the MIC 500 Series
Camera current data, the responses are decoded and data printed and plotted on the display.
PAN : TILT
Indicates the current position in Pan and Tilt in Red and Blue respectively, over the range of 4096
units for 360 degrees rotation.
PWM
Indicates the current PWM (Pulse Width Modulation) of the motor with Pan and Tilt being
indicated in Green and Purple respectively. This indicates how hard the motors are working.
PSU Level
Shows the Voltage level of the main power rail in the MIC 500 Series Camera.
MAIN MENU
2/2
.. MIC INFO 1/15 ..
.. MIC INFO 2/15 ..
SONY SET
CAPTIONS
OFF
GENERAL MIC INFO GOTO
PRESET
MAPPING
PRIVACY
OFF
ADDRESS
:
1
WIPER ON
N/A
POT TEST
SOFTWARE
: 500 A 1.00P
WIPER OFF
N/A
MIC INFORMATION
PROTOCOL
: BOSCH
WASHER ON
N/A
SET USER ACCESS
BAUDRATE
: 9600
WASHER OFF
N/A
HELP
COMMS
:NONE, 8, 1
EXIT
044452198803010002
CAM ZOOM
:18X