MIC412TI and TF Dual Optical/Thermal PTZ Camera
CAMERA MODULE (OPTICAL)
Image sensor
1/4” EXview CCD
Picture elements
380K NTSC / 440K PAL (WIDE)
Horizontal resolution
WDR 36x modules 530 TVL NTSC / PAL
Filter
Automatic mechanical IR cut filter
Focus system
Auto or manual
Iris
Auto or manual with slow shutter integration
modes
Synchronisation
Internal / External (V-Lock)
Signal/Noise ratio
50 dB or more
Back Light Compensation (BLC)
On/Off
White balance
Automatic
Automatic Gain Control (AGC)
-3 to -28 dB, 2dB steps
Aperture control
16 Steps
36x optical zoom module
Lens
F=3.4 mm (WIDE) to 122.4 mm (TELE),
F1.6 to F4.5
Zoom
36x optical (12x digital)
Angle of view
57.8º (WIDE end) to 1.7º (TELE end)
Minimum illumination
1.4 lux (1/60s NTSC, 1/50s PAL, F1.6,
50 IRE),
0.1 lux (1/4s NTSC, 1/3s PAL, F1.6,
50 IRE)
0.01 lux (1/4s NTSC, 1/3s PAL, ICR ON)
Shutter speed
NTSC: 1/4 to 1/10,000s (22 steps)
PAL: 1/3 to 1/10,000s (20 steps)
1/10,000s (20 steps) PAL
CAMERA MODULE (THERMAL)
Lens 50mm
Image sensor
Focal Plane Array (FPA), un-cooled
Vanadium Oxide microbolometer
(MIC412TI: 7.5Hz NTSC, 8.3Hz PAL)
(MIC412TF: US export licence required:
30Hz NTSC, 25Hz PAL)
Picture elements
324 (H) x 256 (V)
Spatial resolution
0.760 mrad with 50 mm lens
Field of view
14° (H) x 11° (V) with 50 mm lens
Focus
Factory-set at infinity focus
Detection range
Human: 780 m (2559 ft)
Object : 2.2 km (7218 ft)
Spectral response
7.5 to 13.5
μ
m
Thermal sensitivity
<85 mK at F1.6
Features
White hot, black hot and false colour
OPERATIONAL*
E-flip Yes
Manual flip
Yes
Presets
64 telemetry presets accurate to less than
0.1° utilising resolver technology (using FV
protocol, 10 camera set-up presets to allow
ANPR, colour correction etc.)
Preset tours
6 tours, each with up to 32 presets
Sector titles
Yes (64 sectors), 20 characters per title
Preset titles
20 character caption for each of the 64
presets
Home position
Yes (preset 1 or tour)
COMMUNICATION & PROTOCOLS
Communication RS485
/
RS422
Control Protocol
Refer to protocol list on datasheet