Video Content Analysis (VCA)
Note
: This section of the manual provides an overview of the fields and the options for each
field on the page
VCA
. This section is not a complete tutorial of setting up
VCA
. For more
information, refer to the separate manual
Video Content Analysis (VCA)
, available on the
product page for Intelligent Video Analytics. Access the product page on the online product
catalog from
http://www.boschsecurity.com/corporate/product-catalog/index.html
When you access the
VCA
menu, the left tab (Video 1) is selected. The Video 1 tab displays
the
VCA
options for the visible camera.
To configure
VCA
options for the thermal camera, select the right tab (Video 2 /
Camera 2
).
VCA configuration
Select one of the profiles here to activate it or edit it.
You can rename the profile.
1.
To rename the file, click the icon to the right of the list field and enter the new profile
name in the field.
2.
Click the icon again. The new profile name is saved.
Do not use any special characters, for example
&
, in the name. Special characters are not
supported by the system's internal management.
If you select the option Silent VCA, then the system creates metadata to facilitate searches of
recordings but no alarm is triggered. You cannot change any parameters for this configuration.
If you want to turn off VCA, then select Off.
If necessary, click the button
Default
to return all settings to their default values. A dialog box
appears with the message, “
Configuration of the video content analysis (VCA) will be reset
to factory defaults. The changes will be lost. Click 'OK' to continue.
” Click
OK
to
acknowledge the message, or click
Cancel
.
Alarm status
The alarm status is displayed here for information purposes. This means you can check the
effects of your settings immediately.
Aggregation time [s]
Set an aggregation time of between 0 and 20 seconds. The aggregation time always starts
when an alarm event occurs. It extends the alarm event by the value set. This prevents alarm
events that occur in quick succession from triggering several alarms and successive events in a
rapid sequence. No further alarm is triggered during the aggregation time.
The post-alarm time set for alarm recordings only starts once the aggregation time has
expired.
Analysis type
Select the appropriate option for Video
Content
Analysis: , Intelligent Video
Analytics, or Intelligent Video Analytics Flow.
Note
: When you select another analysis type, a dialog box appears with the message,
“
Changing the analysis type resets motion and tamper parameters.
” Click
OK
to
acknowledge the message (and to switch analysis types), or click
Cancel
.
Tamper detection
Detect tampering of cameras and video cables by means of various options. Run a series of
tests at different times of the day and night to ensure that the video sensor is operating as
intended.
Sensitivity
and
Trigger delay [s]
can only be changed if
Reference check
is selected.