ON-998-ENTER
: Displays and programs all cameras with or without an address in the
system.
–
ON-997-ENTER
: Displays the current address status of all cameras in the system
simultaneously.
To set an address for a camera without an address:
1.
Select the camera number that you want to
FastAddress
. The system displays the
camera number on the keyboard and the image on the corresponding monitor.
2.
Press
#-ENTER
(where
#
is the camera number without an address).
3.
Press
ON-999-ENTER
to invoke an on-screen display of cameras on the system without
an address.
4.
Follow the on-screen instructions. You receive an on-screen confirmation when the
FastAddress
is complete.
To change or clear an address for a camera with an address:
1.
Select the camera number that you want to
FastAddress
. The system displays the
camera number on the keyboard and the image on the corresponding monitor.
2.
Press
#-ENTER
(where
#
is the camera number with an address).
3.
Press
ON-998-ENTER
to invoke an on-screen display of all cameras on the system, with or
without an address.
4.
Follow the on screen instructions. You receive an on-screen confirmation when the
FastAddress
is complete.
The table below identifies the setting of the thermal camera when you change the address of
the optical camera.
You can change the address of the thermal camera via CTFID; there is no Aux code for this.
5.4.3
FastAddress, Pelco Protocols
This section provides instructions to set a FastAddress with a Pelco keyboard or controller.
–
The optical camera of the MIC612 with an address set to 0 responds to commands set to
any address.
–
Pelco-P
protocol must use addresses 1 to 32.
–
Pelco-D
protocol must use addresses 1 to 254.
To set FastAddress with a Pelco Keyboard:
1.
Press and hold
95-PRESET
for two seconds to open the Pelco Setup menu.
2.
Move the joystick to select the
Command Lock
menu.
3.
Press the
FOCUS
or the
IRIS
button to turn Command Lock to
OFF
.
4.
Move to the
FastAddress
menu and press the
FOCUS
button or the
IRIS
button to open
the menu.
Default Address, Optical New Address, Optical Camera Address, Thermal Camera
0
A number other than 0
The number of the optical
1
A number other than 0
0 or another number
-
No change of address.
-
NOTICE!
A previously-configured MIC612 with an address above 32 (Pelco-P upper limit) or 254 (Pelco-
D upper limit) can be used without readdressing the unit. However, no two (2) addresses can
be the same. For example:
Pelco-P addresses above 32 are repeated in multiples of 32 (1, 33, 65, 97 are the same).
Pelco-D addresses above 254 are repeated in multiples of 254 (1, 255, 509, 763 are the
same).