5.
Install the LTC 8902 Series and LTC 8903 Series matrix bays close enough to the system
LAN switches (LTC 8944/93, LTC 8945/93, and LTC 8946/93) so that the supplied 8 m
(25 ft) LAN cables can be used.
If necessary due to unusual installation conditions, longer standard 10/100Base-T LAN
cables should be obtained from a local computer hardware supplier.
6.
Once installed, exercise care to avoid damaging to the connectors on the matrix bays to
which the LTC 8809/00 ribbon cables are attached. The ribbon cable connectors contain
locking hooks that can be damaged if too much strain is put on the ribbon cables.
If necessary, support the LTC 8809/00 cables to eliminate excessive loading force on the
locking hooks.
7.
Do not mix the different types of supplied LAN cables. The 3 m (10 ft) length is used
between the CPU and LAN switches. The 8 m (25 ft) length is used between the CPU and
the video matrix bays in all system configurations. The 2 m (6 ft) length has reversed data
connections and can only be used between the LTC 8944/93, LTC 8945/93, and LTC
8946/93 LAN switches.
H
LTC 8902
Monitor Bay
LTC 8902
Monitor Bay
LTC 8944 LAN Switch
LTC 8945 LAN Switch
LTC 8903
Camera Bay
LTC 8903
Camera Bay
LTC 8903
Camera Bay
LTC 8903
Camera Bay
LTC 8943
PC Station
LTC 8901 CPU Bay
Figure 6.5: LTC 8900 512 Cameras by 128 Monitors Redundant System Configuration Installed in two (2)
72-in. EIA mounting racks
Main CPU Bay Installation
The LTC 8900 Series Main CPU Bay is supplied fully assembled and requires no user
adjustments. Install CPU bay into the mounting rack. Note, rack-mounting screws and
associated hardware are NOT included.
6.2
LTC 8900 Series
Hardware Installation Procedure for Redundant System Configuration Utilizing LTC 8901
Series CPU | en
37
Bosch Security Systems, Inc.
Installation Manual
2015.01 | 10.6 |