Set-up, gas and electricity connection
Gas connection
Installation must only be performed by an approved expert or a
licensed after-sales service engineer in accordance with the
instructions specified under "Gas connection and conversion to
a different gas type".
For the licensed expert or after-sales service
Caution!
■
The setting conditions for this appliance are specified on the
rating plate on the back of the appliance. The gas type set in
the factory is marked with an asterisk (*).
■
Before setting up the appliance, check the grid access
conditions (gas type and gas pressure) and ensure that the
gas setting of the appliance meets these conditions. If the
appliance settings have to be changed, follow the instructions
in the section "Gas connection and conversion to a different
gas type".
■
This appliance is not connected to a waste gas main. It must
be connected and commissioned in accordance with the
installation conditions. Do not connect the appliance to a
waste gas main. All ventilation regulations must be observed.
■
The gas connection must be made via a fixed, i.e. not mobile
connection (gas line) or via a safety hose.
■
If using the safety hose, ensure that the hose is not trapped
or crushed. The hose must not come into contact with hot
surfaces.
■
The gas line (gas pipe or safety hose) can be connected to
the right or left-hand side of the appliance. The connection
must have an easily accessible locking device.
Safety information
The nominal operating pressure of the appliance is;
For natural gas (G20) 20 mBar, for LPG (G30) 30 mBar, for
LPG (G31) 37 mBar. The appliance must be operated at these
pressure values. All data on the rating plate of your appliance
relates to these pressure values. The manufacturer is not
responsible for results, performance or any risk caused by
operating the appliance at different values.
:
If the gas pressure in your gas supply grid!
for natural gas (G20) is higher than 25 mBar, for LPG (G30) is
higher than 36 mBar, for LPG (G31) is higher than 45 mBar,
you must use your appliance in connection with a suitable gas
regulator, for safety reasons. Connection, maintenance and
configuration of the gas regulator must be performed by an
authorised installation expert. If you do not know the gas
pressure in your gas supply grid, please ask your local supply
grid operator.
Faults in the gas installation/smell of gas
If you notice a smell of gas or faults in the gas installation, you
must
■
immediately shut off the gas supply and/or close the gas
cylinder valve
■
immediately extinguish all naked flames and cigarettes
■
switch off electrical appliances and lights
■
open windows and ventilate the room
■
call the after
sales service or the gas supplier
Moving the appliance by the gas line or door
handle
Do not move the appliance while holding the gas line; the gas
pipe could be damaged. There is a risk of a gas leak! Do not
move the appliance while holding it by the door handle. The
door hinges and door handle could be damaged.
Electrical connection
Caution!
■
Have the appliance set up by your after-sales service. A 16 A
fuse is required for connection. The appliance is designed for
operation at 220-240 V.
■
If the electricity supply drops below 180 V, the electrical
ignition system does not work.
■
Any damage arising from the appliance being connected
incorrectly will invalidate the guarantee.
■
If the supply cord is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualified persons
in order to avoid a hazard.
For the after-sales service
Caution!
■
The appliance must be connected in accordance with the
data on the rating plate.
■
Only connect the appliance to an electrical connection that
meets the applicable provisions. The socket must be easily
accessible so that you can disconnect the appliance from the
electricity supply if necessary.
■
Please ensure the availability of a multi-pin disconnecting
system.
■
Never use extension cables or multiple plugs.
■
For safety reasons, this appliance must only be connected to
an earthed connection. If the safety earth terminal does not
comply with regulations, safety against electrical hazards is
not guaranteed.
■
You must use a H 05 W-F type cable or equivalent for the
appliance connection.