12
| English
1 609 92A 0KH | (28.4.14)
Bosch Power Tools
Keep the measuring tool, the laser target
plate 21 and the holder 10 away from cardi-
ac pacemakers.
The magnets inside the
measuring tool, the laser target plate and the
holder generate a field that can impair the
function of cardiac pacemakers.
Keep the measuring tool, the laser target plate 21 and
the holder 10 away from magnetic data carriers and
magnetically sensitive devices.
The effect of the mag-
nets inside the measuring tool, the laser target plate and
the holder can lead to irreversible data loss.
Product Description and Specifica-
tions
Please unfold the fold-out page with the representation of the
measuring tool and leave it unfolded while reading the operat-
ing instructions.
Intended Use
The measuring tool is intended for determining and checking
horizontal and vertical lines.
Technical Data
Product Features
The numbering of the product features shown refers to the
illustration of the measuring tool on the graphic page.
1
Exit opening for laser beam
2
Tripod mount 1/4"
3
On/Off switch
4
Operating mode button
5
Automatic levelling indicator
6
Laser warning label
7
Serial number
8
Latch of battery lid
9
Battery lid
10
Holder
11
Locking screw for holder
12
Screw holes of holder
13
Opening for strap attachment
14
Magnets
15
1/4" tripod mount on holder
16
5/8" tripod mount on holder
17
Protective pouch
18
Tripod*
19
Laser viewing glasses*
20
Magnets laser target plate
21
Laser target plate*
22
Measuring plate with stand
23
Universal holder BM 1*
24
Telescopic rod*
* The accessories illustrated or described are not included as
standard delivery.
Assembly
Inserting/Replacing the Batteries
Alkali-manganese batteries are recommended for the meas-
uring tool.
To open the battery lid
9
, press the latch of the battery lid
8
in
the direction of the arrow and remove the battery lid. Insert
the supplied batteries. When inserting, pay attention to the
correct polarity according to the representation on the inside
of the battery compartment.
When the batteries become weak, the laser beams flash rap-
idly for about 5 s (while the measuring tool is switched on).
Always replace all batteries at the same time. Only use batter-
ies from one brand and with the identical capacity.
Remove the batteries from the measuring tool when
not using it for extended periods.
When storing for ex-
tended periods, the batteries can corrode and self-dis-
charge.
Cross-line Laser
GLL 2-15
Article number
3 601 K63 7..
Working range, min.
1)
15 m
Levelling Accuracy
±0.3 mm/m
Self-levelling range, typically
±4°
Levelling duration, typically
<4 s
Operating temperature
–10 °C ... +50 °C
Storage temperature
–20 °C ... +70 °C
Relative air humidity, max.
90 %
Laser class
2
Laser type
635 nm, <1 mW
C
6
1
Tripod mount
– Cross-line Laser
– Holder
1/4"
1/4"; 5/8"
Batteries
3 x 1.5 V LR06 (AA)
Operating time, approx.
15 h
Automatic switch-off after approx.
120 min
Weight according to
EPTA-Procedure 01/2003
0.3 kg
Dimensions
80 x 42 x 96 mm
Degree of protection
IP 5X (dust protected)
1) The working range can be decreased by unfavourable environmental
conditions (e.g. direct sun irradiation).
The measuring tool can be clearly identified with the serial number
7
on
the type plate.
OBJ_BUCH-2049-002.book Page 12 Monday, April 28, 2014 4:59 PM