English |
11
Bosch Power Tools
1 609 92A 1A4 | (12.5.15)
Never operate the machine without the portable resid-
ual current device (PRCD) provided.
Products sold in GB only: Never operate the 110 V exe-
cution of the machine without isolation transformer ac-
cording to EN/IEC 61558-1 and EN/IEC 61558-2-23.
The isolation transformer must have a grounded earth
wire on the secondary winding side.
Before starting work, check the proper function of the
portable residual current device (PRCD). Have a dam-
aged portable residual current device (PRCD) repaired
or replaced by your Bosch after-sales service agent.
Pay attention that neither persons in the working area
nor the power tool itself come into contact with the wa-
ter that comes out.
When wet drilling over-
head, the escaping water
must be collected.
To do
this, insert the power tool in-
to a drill stand and mount a
water collecting ring (see
“Accessories/Spare Parts”,
page 14).
Ensure that water-carrying hoses, connectors and the
water collection ring (accessory) are in immaculate
condition. Replace damaged or worn parts before the
next use.
Water escaping from parts of the power tool will
increase the risk of electric shock.
Product Description and
Specifications
Read all safety warnings and all instruc-
tions.
Failure to follow the warnings and in-
structions may result in electric shock, fire
and/or serious injury.
While reading the operating instructions, unfold the graphics
page for the machine and leave it open.
Intended Use
In conjunction with diamond wet-drilling core bits and a water
supply, the power tool is intended for wet drilling in mineral
materials such as concrete, reinforced concrete or brickwork.
The power tool can be combined with an extraction device
(water collection ring and wet/dry vacuum cleaner).
The power tool must only be used together with the diamond
drill stand GCR 350.
Using an anchor, the drill stand for diamond drills can be fas-
tened to the floor, wall and overhead.
The drill stand for diamond drills can be attached to the floor
by means of vacuum (accessory) or (with an additional safe-
guard) against the wall. Attaching overhead is not permitted.
The drill stand for diamond drills can be attached to the floor
using the quick-clamping column. Attaching to a wall or over-
head is not permitted.
Product Features
The numbering of the product features refers to the illustra-
tion of the machine on the graphics page.
1
Drill stand for diamond drills GCR 350*
2
Portable residual current device (PRCD)
3
On/Off switch
4
Star handle*
5
Parking brake*
6
Gear selector
7
Water outlet connector
8
Water tap
9
Core bit*
10
Drill spindle
11
Easy-release element
12
Carrying handle
13
Internal hex screws of the carrying handle
*Accessories shown or described are not part of the standard de-
livery scope of the product. A complete overview of accessories
can be found in our accessories program.
Technical Data
Noise Information
Sound emission values determined according to
EN 61029-2-6.
Typically the A-weighted noise levels of the product are:
Sound pressure level 96 dB(A); Sound power level
110 dB(A). Uncertainty K =3 dB.
Wear hearing protection!
Diamond Drill
GDB 350 WE
Article number
3 601 A89 9..
Rated power input
W
3200
Output power
W
2300
Rated speed n
0
– 1st gear
– 2nd gear
– 3rd gear
min
-1
min
-1
min
-1
420
820
1250
Drilling diameter
– 1st gear
– 2nd gear
– 3rd gear
mm
mm
mm
165–350
80–160
55–105
Tool holder
1 1/4" UNC
Water supply pressure (max.)
bar
3
Weight according to
EPTA-Procedure 01:2014
kg
11.9
Protection class
/
I
Dimensions (incl. removable
product features)
mm
534 x 142 x 168
The values given are valid for a nominal voltage [U] of 230 V. For differ-
ent voltages and models for specific countries, these values can vary.