8.10 Measurement functions
8.10.1 Engine test
Measurement functions
Measuring ranges
Resolution
Sensors
Rotational speed
450 rpm – 6000 rpm
100 rpm – 12000 rpm
250 rpm – 7200 rpm
100 rpm – 500 rpm
10 rpm
10 rpm
10 rpm
10 rpm
Connecting cable B+/B–
Clip-on sensor, secondary sensor,
Connecting cable term. 1
30 A amps clamp, diesel clip-on sensor,
1000 A amps clamp (starter current)
Oil.temp
-20 °C – 150 °C
0,1 °C
Oil temperature sensor
U-Battery
0 – 60 V DC
0.1 V
Battery B+/B– cable
U-Term. 15
0 – 60 V DC
0.1 V
Connecting cable term. 15
U-Term. 1
0 –10 V
0 – 20 V
10 mV
20 mV
Connecting cable term. 1
Ignition voltage,
spark voltage
±50 kV
±10 kV
1 kV
0,1 kV
Connection cable term. 1,
Secondary measuring sensor
Spark duration
0 – 10 ms
0,01 ms
Connection cable term. 1,
Secondary measuring sensor
Relative compression over starter current 0 – 200 Ass
0,1 A
Connecting cable term. 1,
Secondary measuring sensor
U-Alternator ripple
0 – 200 %
0.1 %
CH1 multi measurement cable
I starter
I-Alternator
I-Glow plugs
0 – 1000 A
0.1 A
Amps clamp 1000 A
I-Primary
0 – 30 A
0.1 A
Amps clamp 30 A
Dwell angle
0 – 100 %
0 – 360 °
0,1 %
0,1 °
Connecting cable term. 1
Dwell period
0 – 50 ms
50 – 100 ms
0,01 ms
0,1 ms
Secondary measuring sensor
Amps clamp 30 A
Pressure (atmospheric)
-800 hPa – 1500 hPa
1 mbar
Atmospheric pressure sensor
Duty cycle
0 – 100 %
0.1 %
CH1 / CH2 multi measurement cable
Injection time
0 – 25 ms
0.01 ms
CH1 / CH2 multi measurement cable
Pre-heating time
0 – 20 ms
0.01 ms
CH1 / CH2 multi measurement cable
8.10.2 Multimeter
Measurement functions
Measuring ranges
Resolution
Sensors
Rotational speed
as for engine test
U-Battery
0 – 60 V DC
72 mV
Battery B+/B– cable
U-Term. 15
0 – 60 V DC
72 mV
Connecting cable term. 15
U-DC
min./max.
±200 mV – ±20 V
±20 V – ±200 V
0.001 V
0.01 V
CH1 / CH2 multi measurement cable
I-1000 A
±1000 A
0.1 A
Amps clamp 1000 A
I-30 A
±30 A
0.01 A
Amps clamp 30 A
Resistance
(R-Multi 1)
0 – 1000 Ω
1 kΩ – 10 kΩ
10 kΩ – 999 kΩ
0.001 Ω
0.1 Ω
100 Ω
CH1 multi measurement cable
Pressure P-Air
-800 hPa – 1500 hPa
2,5 hPa
Atmospheric pressure sensor
Pressure P-Fluid
0 – 1000 kPa
0,25 kPa
Oil.temp
-20 °C – 150 °C
0,2 °C
Oil temperature sensor
Air temperature
-20 °C – 100 °C
0,1 °C
Air temperature sensor
Diode test
R
Test voltage
R
Test current
max. 4,5 V
max. 2 mA
Continuity test
0 – 10 Ohm