Commissioning
MS 200 – 6720879925 (2017/11)
32
– Mixer elapsed time CH
(Mixer runtime for central heating backup)
– Solar yield/optimisation
– Gross collector area 1
– Type collector array 1
– Gross collector area 2
– Type collector array 2
– Climate zone
– Min. DHW temp. (Minimum DHW temperature)
– Solar infl. heat. circ. 1 (Heating circuit solar 1…4)
– Reset solar yield
– Reset solar optimisation
– Set temp. Match-F. (Set temperature match-flow)
– Glycol content
– Transfer
– Transfer switch-on diff. (Transfer ON differential)
– Transfer switch-off diff. (Transfer OFF differential)
– Switch-on diff. diff. ctrllr
(ON temperature differential, differential controller)
– Switch-off diff. diff. ctrllr
(OFF temperature differential, differential controller)
– Max source t. diff ctrllr
(Maximum source temperature, differential controller)
– Min. src. temp. diff cont.
(Minimum source temperature, differential controller)
– Max. setbk temp. diff ctrl
(Maximum sink temperature, differential controller)
– Solar DHW
– DHW controller act. (Active DHW controller)
– Therm.dis./daily ht cyl1
(Thermal disinfection/daily heat-up of cylinder 1)
– Therm.dis./daily ht cyl2
(Thermal disinfection/daily heat-up of cylinder 2)
– Therm.dis./daily ht cyl3
(Thermal disinfection/daily heat-up of cylinder 3)
– Daily heat-up time
1)
(Daily heat-up time)
– Daily heat-up temp.
1)
(Daily heat-up temperature)
– Start solar thermal system
Transfer settings
2)
– Change transfer configuration
– Current transfer configuration
– Transfer parameters
– Transfer switch-on diff. (Transfer ON temperature differential)
– Transfer switch-off diff. (Transfer OFF temperature differential)
– Max. DHW temp. (Maximum DHW temperature)
– Daily heat-up time (Daily heat-up time)
– Daily heat-up temp. (Daily heat-up temperature)
– Fault display
DHW settings
3)
– DHW system I
– DHW system I install. (DHW system I installed?)
– Config. DHW at boiler (DHW configuration at the heat source)
– Max. DHW temp. (Maximum DHW temperature)
– DHW
– DHW reduced
– Start temp. differential (ON temperature differential)
– Switch-off temp. diff.
– Flow temp. increase (Increase in flow temperature)
– DHW start delay (Power ON delay for DHW)
– Start cyl. primary pump
– DHW circ. pump installed (DHW circulation pump installed)
– DHW circulation pump
– DHW circ.pmp op. mode
(Operating mode of DHW circulation pump)
– Start frequency DHW circ.
(DHW circulation pump start-up frequency)
– Thermal disinfection
– Therm. disinfection temp.
– Therm. disinfection day (Day for the thermal disinfection)
– Therm. disinfection time (Time of thermal disinfection)
– Daily heat-up (Daily heat-up)
– Daily heat-up time (Time of daily heat-up)
Diagnosis
– Function test
– Activate function tests
– ...
– Solar
– ...
– ...
– Monitored values
– ...
– Solar
– ...
– Fault displays
– ...
– System information
– ...
– Maintenance
– ...
– Reset
– ...
– Calibration
– ...
4.5
Settings menu solar system (System 1)
NOTICE:
Risk of damage to system through pump failure!
▶ Fill and vent the system before switching it on so that the pumps do
not run dry.
The default settings are shown in bold in the adjustment ranges.
The following overview provides a brief description of the
Solar settings
menu. The menus and available settings are described in detail on the
following pages. The menus are dependant on the installed user
interface and the installed solar system.
1) Only available if the module MS 200 is installed in a BUS system, without heat
production.
2) Only available if transfer system is on (code switch is on pos. 8)
3) Only available if primary store system is on (code switch is on pos. 7)