Installation
MS 200 – 6720879925 (2017/11)
29
Caption to the figure above and wiring diagrams at the end of this document
(not designating the terminal
Table 5 to be used for their designations):
Solar thermal system
Function
Additional function in the solar system (shown in grey)
Transfer or primary store system
Transfer or primary store function
Additional function in the transfer or primary store system
(shown in grey)
Earth lead
Temperature/temperature sensor
BUS connection between heat source and module
No BUS connection between heat source and module
[1]
1st cylinder (transfer system 3 stratification cylinder)
[2]
2nd cylinder (transfer system 3 buffer cylinder)
[3]
3rd cylinder (transfer system 3 standby cylinder)
230 V AC Mains voltage connection
BUS
BUS system
M1
Pump or valve controlled via temperature differential
controller
PS1
Solar circuit pump for collector array 1
PS3
Cylinder primary pump for cylinder 2 with pump
(solar system)
PS4
Solar circuit pump for collector array 2
PS5
Cylinder primary pump when using an external heat
exchanger
PS6
Cylinder primary pump for transfer system (solar system)
without heat exchanger (and thermal disinfection)
PS7
Cylinder transfer pump for transfer system (solar system)
with heat exchanger
PS9
Thermal disinfection pump
PS10
Pump for active collector cooling
PS11
Pump on the side of the heat source (primary side)
PS12
Pump on the consumer side (secondary side)
PS13
DHW circulation pump
MS 100
Module for standard solar thermal systems
MS 200
Module for extended solar thermal systems
TS1
Temperature sensor for collector array 1
TS2
Temperature sensor 1 cylinder, bottom
(solar thermal system)
TS3
Temperature sensor 1 cylinder, middle,
(solar thermal system)
TS4
Temperature sensor for heating return to the cylinder
TS5
Temperature sensor 2 cylinder, bottom, or swimming pool
(solar thermal system)
TS6
Heat exchanger temperature sensor
TS7
Temperature sensor for collector array 2
TS8
Temperature sensor for heating return from the cylinder
TS9
Temperature sensor 3; cylinder, top, only connect ton
MS 200 if the module is installed in a BUS system without a
heat source
TS10
Temperature sensor 1 cylinder, top (solar thermal system)
TS11
Temperature sensor 3 cylinder, bottom
(solar thermal system)
TS12
Temperature sensor in flow to solar collector
(heat meter)
TS13
Temperature sensor in solar collector return
(heat meter)
TS14
Heat source temperature sensor
(temperature differential controller)
TS15
Heat sink temperature sensor
(temperature differential controller)
TS16
Temperature sensor 3 cylinder, bottom, or swimming pool
(solar thermal system)
TS17
Heat exchanger temperature sensor
TS18
Cylinder 1 bottom temperature sensor
(transfer/primary store system)
TS19
Cylinder 1 middle temperature sensor
(transfer/primary store system)
TS20
Temperature sensor, 2nd cylinder top (transfer system)
VS1
3-way valve for central heating backup (
)
VS2
3-way valve for cylinder 2 (solar thermal system) with valve
VS3
3-way mixer for return temperature control (
)
VS4
3-way valve for cylinder 3 (solar thermal system) with valve
WM1
Water meter
0 010 013 360-001
N L
N
N 74
N 63
75
L
120/230VAC 120/230VAC
VS1/PS2/PS3
PS1
1
2
1
2
1
2
TS1 TS2
BUS
1
2
BUS
1
2
3
4
1
IS1
2
3
OS1
1
2
TS3
120/230 V AC
≤ 24 V
1
2
1
2
1
2
TS4 TS5
TS7
1
2
TS8
1
2
3
4
1
IS2
2
3
OS2
1
2
TS6
≤ 24 V
N
N 43
N 63
44
63
VS2
PS4
PS5
120/230 V AC
230 V AC 230 V AC
BUS BUS
TS1
TS2 TS3
TS4
TS5 TS6
TS7
TS8
M
VS3*
N
M
N
4
74 75
N 74 75
N 74 75
N 74 75
VS1,
PS2, PS3
PS1
PWM
0-10V
1
2
3
M
VS1*
N L
M
VS2
N L
M
PS1
N L
M
PS3
N L
M
PS5
N L
MS 200
V
TS13
WM1
TS12
PS3
PWM
0-10V
1