background image

Installation Instructions

for the

DX2010 Input Expander

1.0

General Information

The DX2010 is an input expander that connects directly to the data
bus of compatible control/communicators. Each expander allows
an additional eight input loops to be connected to the control/
communicator. See the control panel's literature for programming
instructions.

2.0

Specifications

• Operating Voltage:

8 VDC to 14 VDC

• Current Draw:

35 mA standby; 135 mA max
with connected accessories

• Outputs:

100 mA, 12 VDC supervised
output for accessories

• Sensor Loop Terminal Wire Size: #14 AWG (1.8 mm) to

#22 AWG (0.8 mm)

• Operating Temperature:

+32°F to +122°F
(+0°C to +50°C)

• Relative Humidity:

5% to 85% @ +86°F (30°C)
non-condensing

• Max. Sensor Loop Resistance:

60 W

• Sensor Loop:

Up to eight inputs; input
contacts can be Normally
Open (NO) or Normally
Closed (NC) with
appropriate EOL resistor(s)
for supervision.

• Control Panel Compatibility:

DS7240, DS7220, D6412,
D4412

3.0

Mounting

Failure to follow the instructions in this manual may
result in personal injury and/or damage to the
equipment.

The DX2010 contains static-sensitive components
and must be handled with care. Follow anti-static
procedures when handling the modules.

Test according to NFPA 72 if used in fire applications.

Up to five DX2010 Modules can be installed in the control/
communicator’s enclosure, three on the interior walls and two on
the back wall of the enclosure (see Figures 1 and 2).

DX2010

Side Mounting Locations

DX2010

Terminals

Enclosure Wall

Mounting Hardware

(supplied with DX2010)

Figure 1:  Control Panel Enclosure Side Wall Mounting

Optional mounting locations for the

DX2010 inside the

Control/Communicator Enclosure

Terminals

DX2010

Terminals

DX2010

AE1/D2203 Enclosure

Mounting Clip Assembly

Enclosure

Standoff

Mounting

Clip

Corner of

DX2010 PCB

=

Figure 2:  Control Panel Enclosure Back Wall Mounting

Содержание DX2010

Страница 1: ...with appropriate EOL resistor s for supervision Control Panel Compatibility DS7240 DS7220 D6412 D4412 3 0 Mounting Failure to follow the instructions in this manual may result in personal injury and or damage to the equipment The DX2010 contains static sensitive components and must be handled with care Follow anti static procedures when handling the modules Test according to NFPA72 if used in fire...

Страница 2: ...a Y Figure 5 External Power Supply Connections See Table 1 for the data bus wiring length requirements 22 AWG 0 8 mm 18 AWG 1 2 mm Panel to DX2010 DX2010 AUX Output not used 1000 ft 305 m 2000 ft 610 m Panel to DX2010 DS2010 AUX Output supplying 100 mA 100 ft 30 m 250 ft 76 m Table 1 Wire Lengths Wire length may be restricted by panel limitations See the panel s Installation Guide for more informa...

Страница 3: ... board tamper switch cannot be used if the DX2010 is mounted inside the control panel s enclosure wire the tamper input as shown in Figure 7 if installed in the control panel s enclosure Use either the tamper input or the on board tamper switch Both cannot be used simultaneously 1 R B G Y DX2010 OUT TMPR COM On board tamper switch Figure 7 Tamper Wiring If neither the tamper input nor the on board...

Страница 4: ...switches cycle the power to the DX2010 turn the power off and then on for the address change to take effect L COM L 2 2 k EOL Resistor 2 2 k EOL Resistor 1 5 k or 2 2 k Alarm Resistor 1 5 k or 2 2 k Alarm Resistor Alarm Contacts Tamper Contacts Tamper Contacts Figure 11 Dual Point Zone Input Wiring ON 1 2 3 4 5 6 Status LED Figure 12 DX2010 Status LED ON 1 2 3 4 5 6 OFF ON Example Module Address 1...

Отзывы: