LED
–
+
RELAY
1
2
3
4
5
6
7
8
6 to 15
VDC
Alarm
TROUBLE
INTERFACE
PINS
KEY GUIDE
TAMPER
Figure 3.1: Wiring to terminals
Terminals 1 (-) & 2 (+):
Power contacts.
Terminals 3 (NO), 4 (C), & 5 (NC):
Alarm relay contacts. Use terminals 4
& 5 for Normally Closed circuits. Do not use with capacitive or inductive
loads.
Terminals 6 (T) & 7 (T):
Normally Closed tamper contacts.
Terminal 8 (TR):
Solid state Trouble output. Shorts to ground (-) when the
detector is in a Trouble condition.
}
4 Feature Selection
The DS938Z has several features that are controlled using the confi guration
}
switches.
4 ON
and 5 OFF = 4 Day
Motion
4 OFF and 5 ON
= 30 Day
Monitor
4 OFF and 5 OFF = Disabled
2 ON and
3 OFF = High
Sensitivity
2 OFF and
3 ON
= Intermediate
2 ON and
3 ON
= Standard
1 ON
=
ON
1 OFF
=
OFF
OPEN
Figure 4.1: Selecting features
4.1 LED Operation
ON:
Allows the Alarm/Test LED to operate when activated by
motion.
OFF:
The LED will not operate on alarm activation, but will
indicate a supervision trouble condition.
4.2 Sensitivity Selection
Sensitivity modes depend on the type of coverage desired and the
installation environment.
• Standard
Sensitivity:
Tolerates environment extremes on this setting,
but requires the largest amount of intruder motion to achieve an alarm.
• Intermediate
Sensitivity:
The recommended setting for most
installations. Use in locations where an intruder is expected to
cover only a small portion of the protected area. Tolerates normal
environments on this setting. The detector is shipped in Intermediate
Sensitivity mode.
• High
Sensitivity:
The setting for fast response to intruder signals. For
use only in extremely quiet environments where ceiling drafts, and
thermal and illumination transients are not anticipated.
If both switches are in the OFF position, the unit will default to the
intermediate setting.
NOTICE!
Although the sensitivity modes provide different degrees of tolerance
to environmentally caused alarms, the installer should assure peak
background noise voltage readings do not exceed ±0.15 VDC. (See
Section 8.0 Final Tests).
4.3 Signal Gain
The DS938Z permits selection of the signal gain depending upon the
environment to be protected. The gain select jumper is located under the
optical module. Refer to
Figure 2.3.
• High
Gain:
Recommended for large coverage applications up to 60
ft. (18.3 m) in diameter. The DS938Z is shipped in this setting. If
the gain select jumper is missing, the unit will default to High Gain.
• Low
Gain:
Recommended for applications where the area to be
covered is 40 ft. (12.2 m) or less in diameter and for applications
where High Gain may be too sensitive for environmental extremes.
NOTICE!
Setting the DS938Z for Low Gain reduces the coverage area to 40 ft.
(12.2 m) in diameter.
5 Setup and Walk Testing
1. Attach a TC6000 Test Cord to the Noise Voltage terminals. Since the
outside terminals are common, polarity is not important and the black
lead may be toward or away from the optical module.
2. Attach a Sonalert to the sounder pins at this time if one will be used
during walk testing.
6 © 2013 Bosch Security Systems, Inc.
F.01U.263.663 | 04 | 2013.04 |
7