background image

If the time period selected has elapsed from the last alarm, the LED will 
fl ash two times and the Trouble Output will activate. 

Setting the Motion Monitor timer to shorter periods can be used to force a 
protection walk test of remotely located zones. 

It is recommended that the 30 day timer be selected. This verifi es that 
the unit is operational and avoids nuisance trouble conditions caused by 
holidays, vacations, etc. 

7  Optical Module 

7.1 Optical Module Masking 

Peel-off masks are provided with the unit for each segment of the 

optical module to allow for customized coverage, or to block out areas 

of objects that may cause thermal disturbances. The mask is self­

adhesive and pre-cut in the shape of the optical module. 
The location of the zone to be masked depends on the position of the 

detector. Therefore, determine the mirror surface to be masked before 

removing the mirror from the detector. 
To block out a particular zone or group of zones, peel off a section of 

the mask that corresponds to the appropriate zone, and stick it on the 

mirror segment. Before attempting any masking, be sure the chosen 

mirror surface is the correct one. Refer to 

Figure 7.1

  to identify mirror 

segments and zones. 

NOTICE! 

When disabling the look-down segment, do not mask segment 5 
directly as this will disable the entire detector. Instead, mask the 
segment on the dome directly below segment 5. 

M-4

 

AR8-13

 

AR8-13 

D

 

4

3

2

1

 

4

 

3

 

1

2

5

 

A

 

B

P

 

C

 

E

 

F

 

G

 

H

I

J

 

N

 

O

 

K

 

L

 

M

 

A

 

B

 

C

 

D

 

E

 

F

 

G

 

H

I

J

 

K

 

L

 

M

 

N

 

O

 

P

 

M-3

 

M-2

 

M-1

 

E-1

 

E-2

 

E-3

 

E-4

 

5

 

Figure 7.1: Mirror module to pattern reference 

NOTICE! 

When attempting to remove any masking, many adhesives will either 
destroy the mirror surface or leave enough residue behind to reduce 
coverage performance. 

1 Overview 

The DS938Z is a high performance passive infrared intrusion detector. 
It is equipped with advanced PIR detection and supervision circuits and 
is designed to provide an alarm condition upon detection of an intruder 
passing through its area of coverage. 

Employing balanced dual-opposed sensing elements, the DS938Z passive 
infrared (PIR) detector makes use of the fact that all objects give off (emit) 
infrared energy, and that the warmer an object is, the greater the amount 
of infrared energy given off. The DS938Z uses PIR receiver technology 
designed to detect the change in infrared energy caused when a target of a 
different temperature from a stable background passes through its fi eld of 
coverage. 

The coverage pattern consists of sensor zones arranged to form a circular 
coverage pattern. 

Using Motion Analyzer II circuitry, the detector must fi rst see a change 
in infrared energy in one zone followed by a change of energy in the 
remaining zone. Therefore, disturbances that occur in only one fi nger do 
not constitute motion and are ignored. This “catch sensitivity” may be 
changed in the fi eld by the installer to provide the degree of sensitivity 
required by the installation. 

Self-test and supervision circuits provide reliable operation in a variety of 
installation environments. The result is a highly advanced detector offering 
superior performance with freedom from false alarms. 

Specifi cations 

Dimensions 

(HxDia) 

3.5 in. x 5.25 in. (8.9 cm x 13.3 cm) 

Input 

Power 

6.0 to 15.0 VDC; 5 mA standby, 20 mA in alarm with LEDs enabled. Use only an Approved 
Limited Power Source. 

Alarm Relay  Silent-operating Form “C” relay. Contacts rated <100 mA, 25 VDC, 2.5W maximum, <20 

Ohm closed for DC resistive loads. 

Tamper 

Contacts rated at 28 VDC, 125 mA maximum, <1 Ohm. Connect tamper circuit to a 24­
hour protection circuit. 

Trouble 

Output 

Maximum current load is 25 mA. 

Optional 

Accessory 

TC6000 test cord. 

10  © 2013 Bosch Security Systems, Inc. 

F.01U.263.663 | 04 | 2013.04 | 

                 Available from A1 Security Cameras 

    www.a1securitycameras.com email: [email protected]

Содержание DS938Z

Страница 1: ...ctor with Self Test DS938Z en Installation Guide Bosch Security Systems Inc product manufacturing dates Use the serial number located on the product label and refer to the Bosch Security Systems Inc web site at http www boschsecurity com datecodes 2013 Bosch Security Systems Inc 130 Perinton Parkway Fairport NY 14450 ...

Страница 2: ...tween 13 and 18 ft 4 0 and 5 5 m high use the optical module marked AR13 18 3 To replace an optical module push the optical module tabs towards the center until the module snaps free of the circuit board Holding the new module by the tabs snap the new module into place NOTICE When replacing the mirror make sure it is facing the same direction as before it was removed 4 Replace the enclosure onto t...

Страница 3: ...trusion detector It is equipped with advanced PIR detection and supervision circuits and is designed to provide an alarm condition upon detection of an intruder passing through its area of coverage Employing balanced dual opposed sensing elements the DS938Z passive infrared PIR detector makes use of the fact that all objects give off emit infrared energy and that the warmer an object is the greate...

Страница 4: ...ance 6 3 Coverage Margin Again walk across the farthest edge of required coverage A minimum voltage change of 1 0 VDC from the reference level is required in the wintertime when the background temperature is cool This will make up for summertime when the background is warmer If testing the unit in the summertime the minimum recommended voltage change is 0 75 VDC When testing is completed remove th...

Страница 5: ...Sonalert if installed first turns on may be mounted to standard 4 inch octagonal or square electrical boxes 7 Walk test the unit from all directions to determine the boundaries 8 After completion of the walk tests remove the Sonalert if installed NOTICE 6 Final Tests The DS938Z base will not completely cover a 4 inch square box Where aesthetics are important a 4 inch octagonal box is recommended 6 ...

Страница 6: ...nsitivity mode High Sensitivity The setting for fast response to intruder signals For use only in extremely quiet environments where ceiling drafts and thermal and illumination transients are not anticipated If both switches are in the OFF position the unit will default to the intermediate setting NOTICE Although the sensitivity modes provide different degrees of tolerance to environmentally cause...

Отзывы: