-29°C to +50°C
(-20°F to +120°F )
UL Listed
installations,
the temperature
range is 0°C to +50°C
(+32°F to +120°F)
0 - 95% Relative Humidity
(0 - 85% UL Installations)
Changes or modifi cations not expressly approved
EN 50131-2-2 Grade 2
by Bosch Security Systems, Inc. can void the user’s
EN 50130-5 Environmental Class II
authority to operate the equipment.
IP30 IK04 (EN 60529, EN 62262)
UL
Perform Walk Test at least once a year.
Certifi cat NF A2P 2620001760A1
Use only a Listed limited-power source.
2 boucliers NF324 - H58
The Listed control unit or a Listed burglary power
Autosurveillance à l’ouverture
supply must provide 4 hours (20 mAh) of standby
Immunité champ magnétique
power.
Test sans masque de vision verticale
Install the unit in accordance with National
Electrical Code NFPA 70.
et sans immunité aux animaux
Adjust the microwave range control, if necessary, to
www.afnor.org
achieve maximum range.
www.cnpp.com
SELV
Connect all wiring to a safety extra-low voltage (SELV) circuit only.
Ligue todas as cablagens apenas a um circuito de segurança de tensão extra baixa (SELV).
Conecte el cableado únicamente a un circuito de seguridad para voltajes muy bajos (SELV).
Alle Drähte sind ohne Ausnahme an Niederspannung anzuschließen.
Sluit alle bedrading uitsluitend aan op een circuit met een extra lage veiligheidsspanning.
Prenez soin de connecter tous les câbles à un circuit à très basse tension de sécurité (TBTS).
Collegare tutti i cavi esclusivamente a un circuito SELV (circuito di sicurezza a bassissima tensione).
7.2 Selecting the Optical Module
1. For ceilings between 8 and 13 ft. (2.4 and 4.0 m) from the fl oor, use
the optical module marked AR8-13. This marking can be found next to
the two optical module tabs.
2. For ceilings between 13 and 18 ft. (4.0 and 5.5 m) high, use the optical
module marked AR13-18.
3. To replace an optical module, push the optical module tabs towards
the center until the module snaps free of the circuit board. Holding the
new module by the tabs, snap the new module into place.
NOTICE!
When replacing the mirror, make sure it is facing the same
direction as before it was removed.
4. Replace the enclosure onto the base.
5. Close cover and turn clockwise to secure.
NOTICE!
Avoid fi ngerprints on the mirrored surfaces. Should the mirrored sur
faces become soiled or otherwise marked, they can be cleaned using a
soft, clean cloth and any commonly available, mild window cleaner.
AR8-13
BASEBOARD
HEAT
WINDOW
1 2 3 4
5
4 3 2 1
Region
Certifi cation
Europe
CE
EN50131-2-2, Grade 2
4
3
2
1
5
1
2
3
BASEBOARD HEAT
MASK 3
SECTORS
EN50130-5 Environmental Class II
AFNOR
2620001760A1
AR8-13
AR8-13
1 2 3 4
5
4 3 2 1
4
Poland
TECHOM
98/07 Klasy "C"
UL
1
5
1
2
3
USA
ANSR: Intrusion Detection Units
WINDOW
(UL639)
MASK 15
Sweden
INTYG
04-683
SECTORS
Figure 7.2: Masking
Trademark names are used throughout this document. In most cases, these designations are claimed as
8 Coverage
trademarks or registered trademarks in one or more countries by their respective owners. Rather than
placing a trademark symbol in every occurrence of a trademark name, Bosch Security Systems, Inc.
•
360° by 60 ft. (18.3 m) diameter coverage when mounted on 8 to 18 ft
AR8-13
(hereinafter referred to as Bosch) uses the names only in an editorial fashion and to the benefi t of the
(2.4 to 5.5 m) high ceilings.
trademark owner with no intention of infringing the trademark.
• The coverage pattern consists of 64 zones grouped into 16 barriers,
with one additional zone looking straight down from the unit
(sabotage). Each barrier is 30 ft (9.2 m) long and 4.4 ft. (1.3 m) wide
at 30 ft (9.2 m).
• The DS9382 comes with a choice of two optical modules. Refer to
Section 5.1 to determine the best module for on ceiling height.
2 © 2013 Bosch Security Systems, Inc.
F.01U.263.663 | 04 | 2013.04 |
11