-29°C to +50°C 

(-20°F to +120°F )  
UL Listed 
installations, 
the temperature 
range is 0°C to +50°C 
(+32°F to +120°F) 

0 - 95% Relative Humidity 
(0 - 85% UL Installations) 

Changes or modifi cations not expressly approved 

EN 50131-2-2 Grade 2 

by Bosch Security Systems, Inc. can void the user’s 

EN 50130-5 Environmental Class II 

authority to operate the equipment. 

IP30 IK04 (EN 60529, EN 62262) 

UL 

Perform Walk Test at least once a year. 

Certifi cat NF A2P 2620001760A1 

Use only a Listed limited-power source. 

2 boucliers NF324 - H58 

The Listed control unit or a Listed burglary power 

Autosurveillance à l’ouverture 

supply must provide 4 hours (20 mAh) of standby 

Immunité champ magnétique 

power. 

Test sans masque de vision verticale 

Install the unit in accordance with National 
Electrical Code NFPA 70. 

et sans immunité aux animaux  

Adjust the microwave range control, if necessary, to 

www.afnor.org 

achieve maximum range. 

www.cnpp.com 

SELV 

Connect all wiring to a safety extra-low voltage (SELV) circuit only. 

Ligue todas as cablagens apenas a um circuito de segurança de tensão extra baixa (SELV). 

Conecte el cableado únicamente a un circuito de seguridad para voltajes muy bajos (SELV). 

Alle Drähte sind ohne Ausnahme an Niederspannung anzuschließen. 

Sluit alle bedrading uitsluitend aan op een circuit met een extra lage veiligheidsspanning. 

Prenez soin de connecter tous les câbles à un circuit à très basse tension de sécurité (TBTS). 

Collegare tutti i cavi esclusivamente a un circuito SELV (circuito di sicurezza a bassissima tensione). 

7.2 Selecting the Optical Module 

1.   For ceilings between 8 and 13 ft. (2.4 and 4.0 m) from the fl oor, use 

the optical module marked AR8-13. This marking can be found next to 
the two optical module tabs. 

2.   For ceilings between 13 and 18 ft. (4.0 and 5.5 m) high, use the optical 

module marked AR13-18. 

3.   To replace an optical module, push the optical module tabs towards 

the center until the module snaps free of the circuit board. Holding the 
new module by the tabs, snap the new module into place. 

NOTICE! 

When replacing the mirror, make sure it is facing the same 
direction as before it was removed. 

4.   Replace the enclosure onto the base. 

5.   Close cover and turn clockwise to secure. 

NOTICE! 

Avoid fi ngerprints on the mirrored surfaces. Should the mirrored sur­
faces become soiled or otherwise marked, they can be cleaned using a 
soft, clean cloth and any commonly available, mild window cleaner. 

AR8-13 

BASEBOARD 

HEAT 

WINDOW 

1  2 3 4 

4 3 2 1 

Region 

Certifi cation 

Europe 

CE 

EN50131-2-2, Grade 2 

2

1

5

1

BASEBOARD  HEAT 

MASK 3 

SECTORS 

EN50130-5 Environmental Class II 

AFNOR 

2620001760A1 

AR8-13 

AR8-13 

1  2 3 4 

5  

4 3 2 1

Poland 

TECHOM 

98/07 Klasy "C" 

UL 

1

5

1

3

USA 

ANSR: Intrusion Detection Units 

WINDOW

(UL639) 

MASK 15

Sweden 

INTYG 

04-683 

SECTORS 

Figure 7.2: Masking 

Trademark names are used throughout this document. In most cases, these designations are claimed as 

8 Coverage 

trademarks or registered trademarks in one or more countries by their respective owners. Rather than 
placing a trademark symbol in every occurrence of a trademark name, Bosch Security Systems, Inc. 

• 

360° by 60 ft. (18.3 m) diameter coverage when mounted on 8 to 18 ft 

AR8-13 

(hereinafter referred to as Bosch) uses the names only in an editorial fashion and to the benefi t of the 

(2.4 to 5.5 m) high ceilings. 

trademark owner with no intention of infringing the trademark. 

•   The coverage pattern consists of 64 zones grouped into 16 barriers, 

with one additional zone looking straight down from the unit 
(sabotage). Each barrier is 30 ft (9.2 m) long and 4.4 ft. (1.3 m) wide 
at 30 ft (9.2 m). 

•   The DS9382 comes with a choice of two optical modules. Refer to 

Section 5.1 to determine the best module for on ceiling height. 

2  © 2013 Bosch Security Systems, Inc.  

F.01U.263.663 | 04 | 2013.04 | 

11 

Содержание DS938Z

Страница 1: ...ctor with Self Test DS938Z en Installation Guide Bosch Security Systems Inc product manufacturing dates Use the serial number located on the product label and refer to the Bosch Security Systems Inc web site at http www boschsecurity com datecodes 2013 Bosch Security Systems Inc 130 Perinton Parkway Fairport NY 14450 ...

Страница 2: ...tween 13 and 18 ft 4 0 and 5 5 m high use the optical module marked AR13 18 3 To replace an optical module push the optical module tabs towards the center until the module snaps free of the circuit board Holding the new module by the tabs snap the new module into place NOTICE When replacing the mirror make sure it is facing the same direction as before it was removed 4 Replace the enclosure onto t...

Страница 3: ...trusion detector It is equipped with advanced PIR detection and supervision circuits and is designed to provide an alarm condition upon detection of an intruder passing through its area of coverage Employing balanced dual opposed sensing elements the DS938Z passive infrared PIR detector makes use of the fact that all objects give off emit infrared energy and that the warmer an object is the greate...

Страница 4: ...ance 6 3 Coverage Margin Again walk across the farthest edge of required coverage A minimum voltage change of 1 0 VDC from the reference level is required in the wintertime when the background temperature is cool This will make up for summertime when the background is warmer If testing the unit in the summertime the minimum recommended voltage change is 0 75 VDC When testing is completed remove th...

Страница 5: ...Sonalert if installed first turns on may be mounted to standard 4 inch octagonal or square electrical boxes 7 Walk test the unit from all directions to determine the boundaries 8 After completion of the walk tests remove the Sonalert if installed NOTICE 6 Final Tests The DS938Z base will not completely cover a 4 inch square box Where aesthetics are important a 4 inch octagonal box is recommended 6 ...

Страница 6: ...nsitivity mode High Sensitivity The setting for fast response to intruder signals For use only in extremely quiet environments where ceiling drafts and thermal and illumination transients are not anticipated If both switches are in the OFF position the unit will default to the intermediate setting NOTICE Although the sensitivity modes provide different degrees of tolerance to environmentally cause...

Отзывы: