Installing the inner rails
The chassis includes a set of inner rails which are in two sections: inner rails and inner rail
extensions. The inner rails are pre-attached and do not interfere with normal use of the
chassis if you decide not to use a server rack. Attach the inner rail extension to stabilize the
chassis within the rack.
To install the inner rails:
1.
Place the inner rail extensions on the side of the chassis aligning the hooks of the chassis
with the rail extension holes. Make sure the extension faces "outward" just like the pre-
attached inner rail.
2.
Slide the extension toward the front of the chassis.
3.
Secure the chassis with 2 screws as illustrated.
4.
Repeat steps for the other inner rail extension.
Assembling the outer rails
To assemble the outer rails:
1.
Secure to the front of the rack.
2.
Attach the two sections of the outer rail together.
3.
Secure to the rear of the rack.
4.3.2
4.3.3
DIVAR IP 7000 1U
Rack installation | en
17
Bosch Sicherheitssysteme GmbH
Installation Manual
2014.12 | V3 | DOC