Available from A1 Security Cameras
www.a1securitycameras.com email: [email protected]
20
en | Installation
DINION imager 9000 HD
3.3
Unattach Junction Box
Before mounting the junction box, remove it from the camera
assembly.
1. Use an allen key to loosen the two screws and open the
junction box.
2. Loosen the slotted screws of the input/ output terminal
block (7-pin) and the slotted screws of the power terminal
block (2-pins).
3. Use two wrenches to remove the BNC connector from the
bracket.
4. Disconnect the Ethernet connection.
5. Compress the bottom hinge pin by pushing the pin lever
downward and rotating it behind the hinge pin stop.
Figure 3.3
Camera Box Hinge Alignment
6. Push and hold the top hinge and remove the junction box.
AM18-Q0663 | 1.0 | 2013.09
Installation manual
Bosch Security Systems