Physical
(channel)
value
Choose 'Ohm' to
enter datasheet
values directly.
Select physical
unit.
Enter resistance/
temperature pairs
from sensor data-
sheet here (the
3.01 kOhm pullup-
resistor is auto-
matically taken
into account)
6. Click ‘Next’ when done.
The third part of the ‘Characteristic Curve Wizard’ opens.
Physical
limits of
channel
Enter physical limits
of the channel
Choose data type of
the measurement
variable
This sensor does not
need offset
calibration
Enter name to auto-
matically create a
new measurement
sheet
7. Click ‘Finish’ when done.
8. Enter channel name and description.
9. Click ‘OK’ when done.
The channel is inserted into the DDU 8 Project Tree.
Channel is linked
to ANA05
Input pin Pull-up
resistor is activated
Characteristic
curve for sensor
Adjustment
is disabled
Available measurements for channel:
10 | Analog and Frequency Inputs
86 / 136
DDU S2 PLUS Manual
Bosch Motorsport
Содержание DDU S2 Plus
Страница 1: ...Display DDU S2 Plus Manual Version 1 0 9 16 2016 ...
Страница 13: ...Mechanical Drawing 6 Mechanical Drawing 6 Bosch Motorsport DDU S2 PLUS Manual 13 136 ...
Страница 40: ...7 Select Display Open 8 Select Setting 8 Display Configuration 40 136 DDU S2 PLUS Manual Bosch Motorsport ...
Страница 51: ...7 Select Display Open 8 Select Setting Display Configuration 8 Bosch Motorsport DDU S2 PLUS Manual 51 136 ...
Страница 112: ...Adjustment points vs offset adjustment 11 Online Measurement 112 136 DDU S2 PLUS Manual Bosch Motorsport ...
Страница 135: ......
Страница 136: ...Bosch Engineering GmbH Motorsport Robert Bosch Allee 1 74232 Abstatt Germany www bosch motorsport com ...