CAN Bus
DDU 8 has two fully configurable CAN buses.
▪ Baudrate (125 kBaud … 1 MBaud)
▪ 11 Bit or 29 Bit identifiers
▪ Input configuration: Read messages from CAN bus and convert to DDU 8
measurement/display variables. CAN bus supports row counter configura‐
tion.
▪ Output configuration: Write DDU 8 measurement variables to CAN messages,
output frequency and row counter are configurable, CAN gateway function‐
ality (transfer from one bus to the other).
CAN bus trivia
CAN message
▪ 11 Bit (standard) or 29 Bit (extended) identifier
▪ Up to 8 bytes of data payload
CAN bus
▪ Needs termination resistors (120 Ohm) in wiring harness
▪ All devices connected to the bus must use identical data rate
▪ Configuration of bus data rate in ‘Properties’ menu by double click on the
CAN bus in project tree (1 MBaud, 500 kBaud, 250 kBaud, 125 kBaud).
Row counter concept
▪ Re‐use (multiplex) of message identifiers
▪ One byte of message contains row counter
▪ 7 bytes payload remaining
▪ Position of row counter is configurable
9
9.1
9 | CAN Bus
66 / 136
DDU S2 PLUS Manual
Bosch Motorsport
Содержание DDU S2 Plus
Страница 1: ...Display DDU S2 Plus Manual Version 1 0 9 16 2016 ...
Страница 13: ...Mechanical Drawing 6 Mechanical Drawing 6 Bosch Motorsport DDU S2 PLUS Manual 13 136 ...
Страница 40: ...7 Select Display Open 8 Select Setting 8 Display Configuration 40 136 DDU S2 PLUS Manual Bosch Motorsport ...
Страница 51: ...7 Select Display Open 8 Select Setting Display Configuration 8 Bosch Motorsport DDU S2 PLUS Manual 51 136 ...
Страница 112: ...Adjustment points vs offset adjustment 11 Online Measurement 112 136 DDU S2 PLUS Manual Bosch Motorsport ...
Страница 135: ......
Страница 136: ...Bosch Engineering GmbH Motorsport Robert Bosch Allee 1 74232 Abstatt Germany www bosch motorsport com ...