▪ At power‐up, the reset value (10) is used for ‘p_br_front_mx’.
▪ ‘p_br_front’ rises to 30. As ‘p_br_front’ is > 20 (condition is TRUE), the condi‐
tion ‘max (p_br_front, p_br_front_mx)’ in the THEN window is triggered. The
condition sets the bigger value as new value for ‘p_br_front_mx’. As
‘p_br_front’ (30) is bigger than ‘p_br_front_mx’ (10), the new value for
‘p_br_front_mx’ is set to 30.
▪ Although ‘p_br_front’ falls to 25, the value of ‘p_br_front_mx’ stays 30. This is
caused by the THEN‐condition, because p_br_front_mx’ (30) is still bigger
than p_br_front’ (25).
▪ As ‘p_br_front’ rises to 40. As ‘p_br_front’ (40) is bigger than ‘p_br_front_mx’
(30), the new value for ‘p_br_front_mx’ is set to 40.
▪ As ‘p_br_front’ falls below 20, the IF‐condition turns to FALSE. Now the OTH‐
ERWISE‐condition is triggered. Because the condition ‘p_br_front_mx’ sets the
value of ‘p_br_front_mx’ and the value that is already set to 40 before, noth‐
ing changes.
▪ When ‘p_br_front’ rises to 40, the IF‐condition changes to TRUE again and
triggers the THEN‐condition. Now the reset value (10) is used for
‘p_br_front_mx’ in the THEN‐condition.
▪ Because 40 is bigger than 10 the new value of ‘p_br_front_mx’ is 40.
Condition channels
Condition channel
▪ Logical operations on measurement channel(s)
▪ If‐Else structure with reset
▪ Logical result
▪ Result can be used as input source for Alarm display elements and further
calculations in the whole RaceCon project.
Condition combination
▪ Combination of several (up to 16) condition channels for more complex cal‐
culations
▪ Logical results
All conditions can be used globally in the whole DDU 8 project.
Creating a new condition channel
Follow the steps shown in the screenshot.
8.7
8.7.1
Display Configuration | 8
Bosch Motorsport
DDU S2 PLUS Manual
63 / 136
Содержание DDU S2 Plus
Страница 1: ...Display DDU S2 Plus Manual Version 1 0 9 16 2016 ...
Страница 13: ...Mechanical Drawing 6 Mechanical Drawing 6 Bosch Motorsport DDU S2 PLUS Manual 13 136 ...
Страница 40: ...7 Select Display Open 8 Select Setting 8 Display Configuration 40 136 DDU S2 PLUS Manual Bosch Motorsport ...
Страница 51: ...7 Select Display Open 8 Select Setting Display Configuration 8 Bosch Motorsport DDU S2 PLUS Manual 51 136 ...
Страница 112: ...Adjustment points vs offset adjustment 11 Online Measurement 112 136 DDU S2 PLUS Manual Bosch Motorsport ...
Страница 135: ......
Страница 136: ...Bosch Engineering GmbH Motorsport Robert Bosch Allee 1 74232 Abstatt Germany www bosch motorsport com ...