Telephone Connections
6.1
Registration
The Bosch Security Systems D9412G/D7412G Control
Panels are registered with the Federal Communication
Commission (FCC) under Part 68, for connection to the
public telephone system using an RJ31X or RJ38X jack
installed by the local phone company.
An RJ31X jack can be modified by placing a
jumper wire between Terminals 2 and 7 to
become an RJ38X jack.
6.2
Notification
Do not connect registered equipment to party lines or
coin-operated telephones. The local telephone company
must be notified and given the following information
before connecting the panel to the telephone network:
•
The particular line to which the panel will be
connected
•
Make (Bosch Security Systems), model (D9412G
or D7412G), and serial number of the panel
•
FCC registration number and ringer equivalence
for the panel:
FCC Registration Number:AJ9MUL-46532-AL-E
Ringer Equivalence: 0.1B
6.3
Location
To prevent jamming of signals, wire the RJ31X or
RJ38X jack before the in-house phone system to support
line seizure (see Figure 8). Install the jack on the street
side of the phone switch, wired ahead of any PBX
equipment. Line seizure provides for a temporary
interruption of normal phone usage while the
communicator transmits data. After installation, confirm
the panel seizes the line, acquires dial tone, reports
correctly to the receiver, and releases the phone line to
the in-house phone system.
6.0 Telephone Connections
6.4
Phone Cord Connection
Connect one end of a D161 (2.1 m [7 ft.]) or a D162
(61 cm [2 ft.]) Telephone Cord to the TELCO cord
connector located on the bottom left corner of the panel.
See Figure 9. Connect the other end to the RJ31X or
RJ38X jack.
Figure 9: Phone Connector, Phone LED, and Operation Monitor LED Locations
PHONE
LED
RED
ON WHEN
COMMUNICATING
OFF WHEN IDLE
GRN
E
N
A
B
L
E
D
I
S
A
B
L
E
12
11
13
15
14
16
18
17
19
21
20
22
GROUND START
Requires
Relay Model
D136 in Ground
Start Socket
1
3
2
1 - Telephone cord connector
2 - Phone LED (red)
3 - Operation Monitor LED (green)
To supervise the phone cord, use an RJ38X
jack.
Figure 8: RJ31X Wiring
4
5
8
4
5
8
4
5
8
1
1
1
T1
T
R
R1
RING (red)
TIP (green)
RJ31X
2
7
1
4
3
2
6
5
1 - RJ31X Jack
2 - (TIP)
3- (RING)
4 - TelCo Connector Block
5 - Outside TelCo
6 - Premises telephone
Содержание D7412G
Страница 1: ...D9412G D7412G EN Operation Installation Guide Control Panels ...
Страница 2: ...Bosch Security Systems 10 03 43488E EN 2 D9412G D7412G Operation Installation Guide ...
Страница 10: ...Bosch Security Systems 10 03 43488E EN 10 D9412G D7412G Operation Installation Guide 1 0 Introduction Notes ...
Страница 36: ...Bosch Security Systems 10 03 43488E EN 36 D9412G D7412G Operation Installation Guide 7 0 On Board Points Notes ...
Страница 56: ...Bosch Security Systems 10 03 43488E EN 56 D9412G D7412G Operation Installation Guide Notes 10 0 Arming Devices ...
Страница 60: ...Bosch Security Systems 10 03 43488E EN 60 D9412G D7412G Operation Installation Guide Notes 11 0 SDI Devices ...