D6412/D4412 Operation and Installation Guide
D6412/D4412
Page 47
© 2003 Bosch Security Systems
45349E
Back of Command Center
D6412/D4412 PCB
Y
G
B
R
Red
Yellow
Green
Black
Red
Yellow
Green
Black
External 12 VDC
Power Supply
+
-
Figure 33: External Power for Command Centers
11.3
D268/D269, D279 Independent Zone Control
You can program on-board points 2 to 8 so the D268’s, D269’s, or D279’s (or later versions’) Independent Zone Controls
(IZC) operate as independent point controls (arms and disarms the point).
See Point Index Configuration in the D6412/D4412 Program Entry Guide (P/N: 45351) for programming information. See the
installation literature that accompanies the D268, D269, and D279 (or later versions) for wiring and operation instructions.
To use the D268’s, D269’s, or D279’s (or later versions’) IZC, you must program the panel’s on-board points for
1 k
Ω
Ω
Ω
Ω
Ω
EOL resistors. Points 2 to 8 must all be supervised with 1 kW EOL resistors, even if an IZC is only used for one
point. See
Global Point Configuration
in the
D6412/D4412 Program Entry Guide
(P/N: 45351) for programming
instructions. Only use on-board points 2 to 8 with an IZC. No EOL resistor is used on the points connected to the
IZC.
11.4
Keyswitch
11.4.1
Keyswitch Description
You can connect a maintained or momentary contact arming station (UL Listed security device keyswitch) to master arm/
disarm any of the areas in the system. The keyswitch is connected to an on-board or off-board point’s sensor loop. Outputs
can be programmed to activate arming status LEDs for keyswitch arming stations. See the Outputs section of the D6412/
D4412 Program Entry Guide (P/N: 45351) for more information.
11.4.2
Keyswitch Programming
See Point Index Configuration in the D6412/D4412 Program Entry Guide (P/N: 45351) for point programming for
keyswitches.
Arming Devices