![Bosch CRI SST Скачать руководство пользователя страница 23](http://html.mh-extra.com/html/bosch/cri-sst/cri-sst_operating-instructions-manual_50684023.webp)
Preparation for testing | CRI/CRIN SST | 23 |
en
1 689 989 098
2021-02-24
|
Robert Bosch GmbH
4.3
Connecting the adapter
1.
Clamp the injectors.
2.
Select the appropriate adapter nut (item 2).
3.
Screw the adapter nut onto the adapter (item 1),
and tighten it.
4.
Connect the adapter to the high-pressure inlet of
the injector (item 3).
Tightening torque: 25–30 Nm.
458850-07_Pal
1
2
3
Fig. 11: Adapter installation
5.
Connect the test pressure line or high-pressure
hose assembly to the adapter.
Tightening torque: 25–30 Nm.
i
The operating instructions for tester set CRI/
CRIN 848H describe the connection of injectors.
6.
Make the hydraulic and electrical connections for
the injectors.
4.4
Connecting the pressure sensor
i
When connecting the pressure sensor to the
CRI 800 actuation electronics, make sure to comply
with the channel assignments (injector A to channel
A etc.).
¶
Use connecting cable 1 684 465 868 to connect
the pressure sensor to the sockets for the pressure
sensor on the CRI 800 actuation electronics (see
fig. 2, item 3).
1
2
3
458850-05_Pal
Fig. 9:
Pressure sensor installation
4.
Insert the sealing cone (see Fig. 9, item 2) into the
adapter's pressure sensor mount (item 3).
5.
Screw the pressure sensor (item 1) into the
adapter's pressure sensor mount.
6.
Tighten the pressure sensor by the adapter's hex
nut (see Fig. 10).
Tightening torque: 20 ± 2 Nm.
458850-10_Pal
20 ±2 Nm
Fig. 10: Tightening pressure sensor