27
CR 10 H – 6720876740 (2017/08)
Information for heating contractor
4.5
Energy consumption displays in the service menu
(not for ventilation)
4.6
Operation (example)
Adjustment Unit
Source
Function
period
EC.0
kWh
Fuel
CH
Previous day (0 – 24 h)
EC.1
DHW
EC.2
Electricity
CH
Previous day (0 – 24 h)
EC.3
DHW
EC.4
Fuel
CH
Daily mean
1)
(0 – 24 h)
1) Averaging over the last 30 days
EC.5
DHW
EC.6
Electricity
CH
EC.7
DHW
EC.8
Electricity
Cooling
Previous day (0 – 24 h)
EC.9
Opening the service menu
Operate
Result
▶ Press and hold the selector until 2 dashes are displayed.
▶ Release the selector to display the first setting.
Changing the setting (e.g. heating circuit H.C)
Operate
Result
▶ Select the setting.
▶ Press the selector to display the current value.
▶ Press the selector again to change the value.
°C
°F
°C
°F
°C
°F
°C
°F
°C
°F