background image

Explanation of symbols and safety instructions

3

Compress 7001i/7400i AW AWE – 6721835320 (2021/09)

1

Explanation of symbols and safety instructions

1.1

Explanation of symbols

Warnings

In warnings, signal words at the beginning of a warning are used to 
indicate the type and seriousness of the ensuing risk if measures for 
minimizing danger are not taken.

The following signal words are defined and can be used in this document:

DANGER

DANGER

 indicates that severe or life-threatening personal injury will 

occur.

WARNING

WARNING

 indicates that severe to life-threatening personal injury may 

occur.

CAUTION

CAUTION

 indicates that minor to medium personal injury may occur.

NOTICE

NOTICE

 indicates that material damage may occur.

Important information

The info symbol indicates important information where there is no risk to 
people or property.

Additional symbols

Table 1

1.2

General safety instructions

1.2.1

Application area

The heat pump may only be used in sealed heating systems according to 
EN 12828.
Other uses are not appropriate. Any damage that results from such use is 
excluded from liability.

The heat pump must undergo maintenance according to EN1717 4.6.

H

Safety of electrical devices for domestic use 
and similar purposes

The following requirements apply in accordance with 
EN 60335-1 in order to prevent hazards from 
occurring when using electrical appliances:
“This appliance can be used by children of 8 years and 
older, as well as by people with reduced physical, 
sensory or mental capabilities or lacking in experience 
and knowledge, if they are supervised and have been 
given instruction in the safe use of the appliance and 

understand the resulting dangers. Children shall not 
play with the appliance. Cleaning and user 
maintenance must not be performed by children 
without supervision.”
“If the power cable is damaged, it must be replaced by 
the manufacturer, its customer service department or 
a similarly qualified person, so that risks are avoided.”

H

Inspection and maintenance

Regular inspection and maintenance are prerequisites 
for safe and energy efficient operation of the heating 
system.
We recommend you enter into a contract for the 
annual inspection and demand-dependent 
maintenance with an authorised installer.
▶ Have work carried out only by an approved installer.
▶ If any faults are discovered, have them remedied 

immediately.

H

Inspection and maintenance

If there is a lack of cleaning, inspection or 
maintenance, or if these are carried out incorrectly, 
this may result in material damage and/or personal 
injury, including possible risk to life.
▶ Have work carried out only by an approved 

contractor.

▶ Do not take off the heat pump cover.
▶ Do not modify the heat pump or other parts of the 

heating system.

H

Room air

The air in the installation room must be free of 
combustible or chemically aggressive substances.
▶ Do not use or store combustible or explosive 

materials (paper, propellants, thinners, paints, 
etc.) within the vicinity of the appliance.

▶ Do not use or store corrosive substances (solvents, 

adhesives, chlorinated cleaning agents, etc.) within 
the vicinity of the appliance.

H

Damage caused by frost

The solar system can freeze if it is switched off:
▶ Observe the notices regarding frost protection.
▶ Due to the additional functions, e.g. DHW heating or 

pump anti-seizure protection, the system should 
always be left on.

▶ Correct any faults immediately.

H

Risk of scalding at the DHW draw-off points

▶ If DHW temperatures above 60 °C are set or if 

thermal disinfection is activated, a mixer must be 
installed. If in doubt, ask your installer.

Symbol

Meaning

a step in an action sequence

a reference to a related part in the document

a list entry

a list entry (second level)

Содержание Compress 7001i AW

Страница 1: ...6721835320 2021 09 GB User Guide Air Water Heat Pump Compress 7001i 7400i AW AWE Heat pump with indoor unit ...

Страница 2: ...the time program automatic mode 9 3 2 8 Selecting active time program for the heating system 10 3 2 9 Renaming a time program or heating circuit 10 3 2 10 DHW settings 11 3 2 11 Setting up a holiday program 11 3 2 12 More settings 12 3 3 Main menu 13 3 3 1 Heating settings 13 3 3 2 DHW settings 14 3 3 3 Settings for the venting function 15 3 3 4 Setting up a holiday program 15 3 3 5 Settings for o...

Страница 3: ...t be performed by children without supervision If the power cable is damaged it must be replaced by the manufacturer its customer service department or a similarly qualified person so that risks are avoided H Inspection and maintenance Regularinspectionandmaintenanceareprerequisites for safe and energy efficient operation of the heating system We recommend you enter into a contract for the annual ...

Страница 4: ...ity is available on the Internet worcester bosch co uk 2 3 Heat pump outdoor unit The heat pump is inverter operated which means that it will automatically change the compressor speed to deliver the exact amount ofenergyrequiredatthemoment ThefanisalsoRPMcontrolledandwill change its speed as needed This provides the lowest possible energy consumption The speed changes have an effect on the sound e...

Страница 5: ...is connected to the unit AWE an external DHW cylinder must be connected if the heat pump is to produce hot water The change between heat and hot water is then controlled via an external 3 way valve The integrated booster heater in the indoor unit is started if necessary Fig 3 Heat pump Compress 7001i 7400i AW indoor unit AWE with electric booster heater and external hot water cylinder 2 5 Hints on...

Страница 6: ...thermal disinfection Dependingonthesoftwareversionoftheuserinterface thetextsshown in the display may differ from the texts in these instructions The adjustment ranges default settings and functional scope may differ from the information in these instructions depending on the system installed at the site If 2 or more heating circuits are installed settings for different heating circuits are availa...

Страница 7: ...circuit Heat source temperature if there are no remote control installed 2 Info line display of time of day day of the week and date 3 Additional temperature display outside temperature temperature of the solar collector or a DHW system For ventilation display of the ventilation level For ventilation frost protection reduced ventilation 4 Text information e g the designation of the temperature cur...

Страница 8: ...ndow is displayed and thetimeprogramisactivated The currently valid temperature flashes Activating optimised operation without time program If automatic mode is active Press the menu key Press the selector to open the Heating or Heating Cooling menu Press the selector to open the Op mode menu Highlight the desired heating circuit and press the selector Choose Optimise and press the selector Press ...

Страница 9: ...program for the heating system Turn and press the selector to activate the input field for a switching time Set and confirm the switching time Adjusting the temperature operating mode for a time slot Open the menu for adapting a time program for the heating system Turnandpresstheselectortoactivatetheinputfieldfortheoperating mode of a time slot Set and confirm operating mode Deleting switching tim...

Страница 10: ... available if 2 or more heating circuits are installed Open the main menu Open Heating or Heating Cooling Time program Heating circuit 1 Rename heating circuit menu or other heating circuit The cursor flashes to indicate the start position for data input Entering adding characters Open menu for renaming a time program or heating circuit Turn the selector to position the cursor in the required loca...

Страница 11: ...HW Extra hot water Set the maximum DHW temperature and duration as desired Select and confirm Start now Select Yes in the pop up window and confirm The water heating becomes active immediately Once the set duration time has expired the extra DHW cylinder charging switches off again automatically Open the menu for adapting the time program for DHW heating Open the main menu Open the DHW Time progra...

Страница 12: ...Select Yes in the pop up window and confirm The holiday program is deleted 3 2 12 More settings Setting the time and date If the user interface has been disconnected from the power supply for a prolonged period the date and time must be set Restore the power supply The user interface displays the setting for the date Set the day month and year respectively and confirm Confirm Next The user interfa...

Страница 13: ...e My time program 1 Resetting prog The default setting for My time program 2 can be restored here Rename time prog The names of the time programs can be changed in the same way as the names of the heating circuits This helps to select the correct time program e g family or night shift Menu item Description Heating Cooling In summer heating cooling mode can be switched off Continuous summer The hea...

Страница 14: ...y heat up outside normal hours of use Make sure that a thermal mixer is installed If in doubt ask your installer Menu Autom therm disinfect Table 10 Settings for thermal disinfection Menu item Description Op mode Off Deactivated no DHW production Always on DHW Eco 1 Lowest DHW temperature mode that results in lowest energy consumption Always on DHW Eco Medium DHW temperaturemodethatresultsinmedium...

Страница 15: ... time prog 6 switching times can be set for each day or group of days The DHW circulation pump can be switched on or off at each switching time The minimum duration of a time slot between two switching times is 15 minutes Resetting prog The time program is reset to factory default Menu item Description Op mode Select vent operating mode Sleep High vent rate high ventilation rate Auto time program ...

Страница 16: ...ure may be increased Forced peak 2 5 C Set how much the room temperature is forced to increase DHW The energy available in the smart grid is used for DHW Selectable peak Yes No If enabled the DHW is heated to the temperature set for DHW operating mode Always on DHW comfort No heating is done if the holiday program is active Menu item Description Menu item Control range Function description Heating...

Страница 17: ...valid in the selected heating circuit Inautomaticmode thiscanchangeseveraltimes a day if necessary In normal operation it is always constant Measured room temp Currently measured room temperature in the selected heating circuit Measured flow temp Currently measured flow temperature in the selected heating circuit Menu item Description Menu item Description Set temp Desired DHW temperature Measured...

Страница 18: ... consumed by the electric booster heater Heating Cumulatedenergyconsumedbytheelectricbooster heater in heating mode DHW Cumulatedenergyconsumedbytheelectricbooster heater in DHW mode Pool Cumulatedenergyconsumedbytheelectricbooster heater in pool heating mode Menu item Description Total Cumulated total energy consumed by the heat pump Heating Cumulated energy consumed by the heat pump in heating m...

Страница 19: ...more frequent intervals If a lot of magnetic dirt is clinging to the magnetic bar in the particulate filter and that dirt frequently causes an alarm related to the poor flow e g low or poor flow high flow supply or HPalarm anapprovedmagnetitefilter mustbeinstalledtoavoidregular drainingoftheindicator Themagneticfiltermustbeinstalledinaddition to the mesh filter and be placed in the secondary circu...

Страница 20: ...acks and damage on the casing with anti corrosive paint Standard car wax can be applied to protect the paint 4 2 2 Evaporator Any layers of dust or dirt for example deposited on the surface of the evaporator must be removed CAUTION The aluminium fins are thin and sensitive They can be damaged easily due to careless handling Never use hard objects Never rub the fins directly with a cloth Wear prote...

Страница 21: ...upport TheIPmodulecanbeusedtocontrolandmonitorthesystemviaamobile device It is used as an interface between the heating system and a network LAN and also enables the SmartGrid function The IP module is installed as standard in a number of products and can be retrofitted to others as an accessory To take advantage of all the functions an Internet connection and router with a free RJ45 output are ne...

Страница 22: ...ce Login data for the IP module Manuf no _________________________________________________________________ Login name _______________________________________________________ Password _______________________________________________________________ Mac _____________________________________________________________________ 4 4 Information on refrigerant This device contains fluorinated greenhouse gase...

Страница 23: ...ther information are provided on request You can contact our Data Protection Officer under Data Protection Officer Information Security and Privacy C ISP Robert Bosch GmbH Postfach 30 02 20 70442 Stuttgart GERMANY You have the right to object on grounds relating to your particular situation or where personal data are processed for direct marketing purposes atanytimetoprocessingofyourpersonaldatawh...

Страница 24: ...is heated in accordance with the time program and switching between the operating modes occurs automatically Operating phase The heating operating phases are heating and setback They are depicted by the symbols and The operating phases for DHW heating are DHW DHW reduced and Off A temperature can be set for each operating phase except for Off Frost protection Depending on the type of frost protect...

Страница 25: ...ng priority for Circulation Op mode Start frequency My circulation time prog circulation time program Resetting prog reset circulation time program Ventilation Op mode Time program Reset time prog Humidity Air quality Bypass Supply air temp control Reheat supp air temp After heater supply air temperature Filter timer Confirm filter change Rename ventil zone Pool Switch on pool heating Pool tempera...

Страница 26: ... cool Op hours for comp DHW Op hours for comp pool Number of heating starts Number of cooling starts Number of DHW starts Number of pool starts Energy consump Total Electric auxiliary heater Total Heating DHW Pool Compressor Total Heating DHW Cooling Pool 24h ventil current 30d ventil current Energy supplied Total energy suppl Heating energy suppl DHW energy suppl Emitted cooling energy Pool energ...

Страница 27: ...Overview Info 27 Compress 7001i 7400i AW AWE 6721835320 2021 09 ESC block PV system Smart grid Current operation COP heat source ...

Страница 28: ... Cotswold Way Warndon Worcester WR4 9SW United Kingdom Tel 0330 123 9559 worcester bosch co uk 0330 123 3366 TECHNICAL SUPPORT RENEWABLE SUPPORT 0330 123 9229 CONTROLS AND CONNECTIVITY TEAM 0330 123 3641 0330 123 9339 0330 123 9779 0330 123 9119 0330 123 0166 0330 123 9669 ...

Отзывы: