24
en | Programming
Carephone 61
F.01U.239.30x | V1 | 2011.06
User Manual
Bosch Security Systems
71 Action button (S button)
The Action button can be configured differently according to your needs:
–
0
= off
–
1
= service button / direct call (e.g. service call to a monitoring centre
or direct call to a relative)
–
3
= activate relay output (e.g. a door opener)
72 Activate output
The Carephone 61 provides a potential-free relay output with a normally
open switch contact. The way the output reacts can be programmed.
–
0
= off
–
1
= speak / listen connection and repeated emergency call
–
3
= outgoing emergency call
–
4
= incoming call recognition
–
5
= wireless transmitter
–
6
= remote activation
–
7
= speak / listen connection
–
8
= pre-alarm
–
9
= pre-alarm and speak / listen connection
73 Assign input
The Carephone 61 provides external inputs. The function assigned can be
programmed:
–
1
= emergency call button
–
2
= service call
–
3
= external input
After your choice, the input can be chosen as a:
–
0
= normally open contact (closing)
–
1
= normally closed contact (opening)
74 Silent alarm
The Carephone 61 can send silent alarms. When this is activated, the
loudspeaker of the Carephone 61 is turned off. Only the microphone
remains active.
–
0
= off,
1