99
PWM
P
ulse
W
idth
M
odulation
Output frequency is constant
‘On time’
(duty cycle) controlled by input
channel
C 60 has 4 PWM outputs
Low-side switch
Up to 2A each
Selectable output frequency
Duty cycle controlled by characteristic
curve
Configuring a PWM Output
Drag the ‘PWM Out’
computed source
from the Toolbox and drop it on the
desired ‘PWM Out’
channel in the C 60
project tree
A ‘PWM Out Wizard’
opens
C 60 Analog and Frequency Inputs
Internal | BEG/EMS1 CsM
| 6/4/2010 | ©
Bosch Engineering GmbH 2009. All rights reserved, also regarding any disposal, exploitation,
reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
Motorsport
Configuring PWM Outputs
Output frequency
Output frequency
Duty cycle 20%
(switch closed)
Duty cycle 80%
Time
Time
U
out
U
out
Pin
LS_SWITCH
+12V
Load
electronic
switch
C 60
Pin
LS_GND 1+2
GND